Reasons why you you would wire a boiler up opentherm instead of 240 volt switching

  Рет қаралды 33,790

Baxi - sustainable heating and hot water solutions

Baxi - sustainable heating and hot water solutions

Күн бұрын

Пікірлер: 32
@AllenHart999
@AllenHart999 4 жыл бұрын
Love Roy, Amazing guy.
@brendanfisher2528
@brendanfisher2528 4 жыл бұрын
I did the training day with roy. Great guy. Looking better after the weight loss. All the best with it roy
@fbazsa
@fbazsa Жыл бұрын
Hello! I'm using a Baxi Luna Duo-tec E boiler with a Mago thermostat. I have an issue where the Heating Curve and Control Strategy menu points are not accessible. According to the manual: "The display shows the Heating Curve only if your installation is fit for this option." Could you please provide information on the requirements for configuring this setting?
@45graham45
@45graham45 2 жыл бұрын
What never seems to be mentioned is that to make Open Therm work you need the link in the boiler removed (just as you would for a normal on / off thermostat) & also you need to activate Open Therm in the Nest thermostat - in: settings, pro setup, continue, combi & then select heat with Open Therm.
@pennyhardaway7491
@pennyhardaway7491 11 ай бұрын
On the Baxi 830 combi 2, to use OpenTherm you must remove the link and put a link in the 240v RT (traditional). Or vice versa if you wish to use the RT 240v, place a link in the OpenTherm block. My Google Nest 3rd Gen would not fire the heating as I had no link in 240v RT. There is no mention of this in the service manual.
@MuhammadAdeelAhmed
@MuhammadAdeelAhmed 4 жыл бұрын
Looking for the training on how to install opentherm Nest Gen 3 with Ideal C35 combi boiler ? Any tips/diagram/vid please share, thanks
@kevinleesmith
@kevinleesmith 2 жыл бұрын
1) Does a modulating boiler only modulate down the burner, or does it also modulate the rad pump flow rate? 2) is the modulation power (kw) set by the opentherm stat or is the flow temp set by an opentherm stat and then the boiler chooses the appropriate kW? 3) if I use a weather compensating control like a google nest, does that automatically set the boiler output or does it set the flow temperature?
@06howea1
@06howea1 2 жыл бұрын
Great questions we need clarity on all of this!
@Dodge2703
@Dodge2703 3 жыл бұрын
So you have to remove the link on the traditional on/off thermostat connection when using the opentherm connection?
@45graham45
@45graham45 2 жыл бұрын
yes. What never seems to be mentioned is that to make Open Therm work you need the link in the boiler removed (just as you would for a normal on / off thermostat) & also you need to activate Open Therm in the Nest thermostat - in: settings, pro setup, continue, combi & then select heat with Open Therm.
@45graham45
@45graham45 2 жыл бұрын
Does the link at the boiler need to be removed if Open Therm is used or only if the normal on / off relay terminals are used?
@45graham45
@45graham45 2 жыл бұрын
Yes, I now know that it does need to be removed.
@tomhilditch3882
@tomhilditch3882 4 жыл бұрын
Hi any chance of a Usense specific video. Its such a good control. I have one installed on a system boiler with the Priory hw bloody smart. I would like to WC it but the information is not really there.
@06howea1
@06howea1 2 жыл бұрын
My boiler is old switching it doesnt do open therm 😢
@davecavaghan7889
@davecavaghan7889 9 ай бұрын
Are you really saying opentherm was available on baxi or any boilers in 2004 ?
@ionsprinceana5048
@ionsprinceana5048 4 жыл бұрын
Does anybody k of if the OT comply with boiler+?
@CrashUK28
@CrashUK28 3 жыл бұрын
Why don't plumper know what opentherm is?. I had to wire in my own control to get Opentherm to work.
@dontcare32123
@dontcare32123 2 жыл бұрын
Sadly this boiler and the Main ECO Compact (same boiler) are not compatible with Honeywell Evohome as Baxi, unlike many other boiler manufacturers, lockout the flow controls on the boiler front. The reason they do this is to push you towards the Baxi Opentherm controller but this won't run multiple zones unlike Evohome. Unfortunately Evohome does not provide flow control as Honeywell believe flow control should be maintained at the boiler, so you're stuffed with this combination or any other controller with Baxi that doesn't allow flow control. Gutted!
@pointypipedream
@pointypipedream 4 жыл бұрын
If only it was wirless 🙏
@dontcare32123
@dontcare32123 2 жыл бұрын
We have a Baxi 600 combi connected to a Honeywell R8810 Opentherm bridge and an Evohome Evotouch. Since connecting the Opentherm bridge, the boiler controls are now locked out with DCH set at 80 and DHW at 60. I'm assuming these are the maximum temperatures allowed but I would ideally like some control of the hot water temperature and I would also like to set DHW to 55c max but I can't see any way of doing either of these through the Evohome Touch. Any ideas?
@davidgreen4975
@davidgreen4975 3 жыл бұрын
cant wait to explain this to my older generation customers. I would have to move in with them!! Its a no thanks from me!
@LVBRIP
@LVBRIP 3 жыл бұрын
Thanks for the info. Explains it all. Pls consider deleting the horrible music in future, nobody likes it.
@strider0106
@strider0106 4 жыл бұрын
So the benefit to why we should fit Open Term is an app!!!!! Is that it, or have I missed something
@edc1569
@edc1569 4 жыл бұрын
Pretty sure the main point is so the flow temperature tracks heating demand, curious why that wasn't mentioned.
@ravingtorpedo8045
@ravingtorpedo8045 4 жыл бұрын
I think its to do with modulation unless thats just auto?
@chrissadowski2669
@chrissadowski2669 4 жыл бұрын
Waste of time , app is the benefit of an open therm
@JM-uo5vp
@JM-uo5vp 9 ай бұрын
You you
@mrt227zxr
@mrt227zxr 3 жыл бұрын
Plug the boiler in and switch off when not in use, most efficient way to use, science
@futhark3899
@futhark3899 4 жыл бұрын
Do we need all this crap on what is essentially just another white goods, product, are we going to do this to washing machines, and tumble dryers?
@Leonards-leopard
@Leonards-leopard 2 жыл бұрын
Modern front loading washing machines and tumble dryers are both capable of modulating speed so yes, we have
How to remove and clean the inline strainer on a Megaflo cylinder
2:51
Baxi - sustainable heating and hot water solutions
Рет қаралды 33 М.
What is OpenTherm / Weather Comp
11:05
Allen Hart
Рет қаралды 25 М.
REAL or FAKE? #beatbox #tiktok
01:03
BeatboxJCOP
Рет қаралды 18 МЛН
It’s all not real
00:15
V.A. show / Магика
Рет қаралды 20 МЛН
Lockdown Learning - The recommended basic electrical safety checks you should perform
9:11
Baxi - sustainable heating and hot water solutions
Рет қаралды 28 М.
I reduced our gas usage by 30% for hot water by doing these 3 easy things
13:05
Tim & Kat's Green Walk
Рет қаралды 571 М.
How to install wire a Baxi Usense controller
9:59
WoW! Warriors of Warmth Plumbing Happy to help
Рет қаралды 4,7 М.
What to do if there is water coming from the PRV on a boiler
7:49
Baxi - sustainable heating and hot water solutions
Рет қаралды 43 М.
You Won't Believe What This Boiler service uncovers! THIS WILL SHOCK YOU
14:14
Blue Bulldog Plumbing
Рет қаралды 21 М.
Combi Boiler Thermostat Wiring
26:16
John Ward (jwflame)
Рет қаралды 273 М.
Shunta värmesystem
6:33
RörmokarLäraren
Рет қаралды 27 М.
REAL or FAKE? #beatbox #tiktok
01:03
BeatboxJCOP
Рет қаралды 18 МЛН