Beam dimension and Longitudinal reinforcement.Detailing of beam as perIS:13920-2016 & Amendment 1&2.

  Рет қаралды 2,207

Civil Basics 21

Civil Basics 21

Күн бұрын

Detailing of beam
drive.google.c...
Detailing of is 13920
• Detailing of is 13920 ...

Пікірлер: 14
@AdityaSingh-jn1kw
@AdityaSingh-jn1kw 2 жыл бұрын
Great work sir 🙏 It's helpful...
@civilbasics21
@civilbasics21 2 жыл бұрын
Keep watching
@ArnabBhattacharyya
@ArnabBhattacharyya 2 жыл бұрын
Grt going sir...waiting for next ones
@civilbasics21
@civilbasics21 2 жыл бұрын
Thanks. Here is your next video.
@Chakrawartiabhas
@Chakrawartiabhas 2 жыл бұрын
🙏🙏🙏🙏....
@izaanahmad7494
@izaanahmad7494 Жыл бұрын
Sir, how to overcome "Column failure due to biaxial bending", it occured in corner -middle column, I designed it for 300x450 & kept on increasing size to overcome the biaxial bending failure and the column finally passed at 300 x 900. The analysis was done of structural designing software. Guidance please
@soorajkumar1423
@soorajkumar1423 Жыл бұрын
Sir I have a doubt(6.2.5), in case depth of beam+ width of column is less than the X value , then that extra length what should we do? Ex . Depth of beam = 450mm, Width of column = 300mm Bar provided top main= 25mm (take Ld =50d) Then X = 1250+10*25-8*25 = 1.3m But available for us to provide = 0.30+0.45 = 0.75m Please comment sir.
@civilbasics21
@civilbasics21 Жыл бұрын
Horizontal part will be less than 300 mm and rest extra length will go into the column below the bottom of beam level or otherwise bend it again into the beam namaste. Here again 8d for this 90 degree bend will be substracted.
@soorajkumar1423
@soorajkumar1423 Жыл бұрын
Okay sir in case column is already casted till beam bottom(most of the case) , means U bend has to be given. Thank u soo much sir..❤..
@izaanahmad7494
@izaanahmad7494 Жыл бұрын
Sir, Ast(min/required) and Ast(provided) - How much difference is acceptable?
@civilbasics21
@civilbasics21 Жыл бұрын
There's no limitations. Think yourself in respect of economy and extra safety.
@muhammadsufiyan4584
@muhammadsufiyan4584 2 жыл бұрын
Sir what is 'Ldt' in 6.2.5 in figure
@civilbasics21
@civilbasics21 2 жыл бұрын
I have told watch again carefully
@muhammadsufiyan4584
@muhammadsufiyan4584 2 жыл бұрын
@@civilbasics21 ok sir ji
Shear / Transverse Reinforcement.Detailing of beam(is13920),
29:17
Civil Basics 21
Рет қаралды 1,6 М.
Dad gives best memory keeper
01:00
Justin Flom
Рет қаралды 24 МЛН
(5) Example on Rigid and flexible base plate (IS:800-2007)
23:01
Civil Basics 21
Рет қаралды 387
Psychology Professor's Viral Study Techniques: A+ Students Love It! (Part 1)
9:27
ALL OF PHYSICS explained in 14 Minutes
14:20
Wacky Science
Рет қаралды 2,3 МЛН
how to anchor bolt work leveling and stake out
11:26
Zahoor Ahmad official
Рет қаралды 19 М.
Concrete Shear Wall Design (ACI 318-19)
8:24
CalcBook
Рет қаралды 11 М.