Beam का Steel कैसे लगाते हैं? | Beam Reinforcement in Detail | Top Extra Bars कैसे लगाते हैं?

  Рет қаралды 110,624

REINFORCE

REINFORCE

Күн бұрын

Пікірлер: 54
@ReinforceInstitute
@ReinforceInstitute Жыл бұрын
🟢 𝐅𝐨𝐫 𝐨𝐟𝐟𝐥𝐢𝐧𝐞 𝐓𝐫𝐚𝐢𝐧𝐢𝐧𝐠/ 𝐨𝐧𝐥𝐢𝐧𝐞 𝐥𝐢𝐯𝐞 𝐬𝐞𝐬𝐬𝐢𝐨𝐧 𝐨𝐫 𝐚𝐧𝐲 𝐚𝐬𝐬𝐢𝐬𝐭𝐚𝐧𝐜𝐞 𝐲𝐨𝐮 𝐦𝐚𝐲 𝒄𝒂𝒍𝒍 𝒐𝒓 𝑾𝒉𝒂𝒕𝒔𝑨𝒑𝒑 𝒂𝒕 +𝟵𝟭𝟵𝟳𝟭𝟭𝟭𝟱𝟱𝟱𝟴𝟱 🔴𝐅𝐨𝐫 𝗥𝗲𝗰𝗼𝗿𝗱𝗲𝗱 𝐬𝐞𝐬𝐬𝐢𝐨𝐧 𝐃𝐨𝐰𝐧𝐥𝐨𝐚𝐝 𝐑𝐞𝐢𝐧𝐟𝐨𝐫𝐜𝐞 : 𝐂𝐢𝐯𝐢𝐥 𝐄𝐧𝐠𝐢𝐧𝐞𝐞𝐫𝐬 𝐥𝐞𝐚𝐫𝐧𝐢𝐧𝐠 𝐚𝐩𝐩. 👉𝐀𝐧𝐝𝐫𝐨𝐢𝐝 𝐚𝐩𝐩 𝐥𝐢𝐧𝐤 : bit.ly/425ebrk 👉𝐖𝐞𝐛/𝐏𝐂/𝐋𝐚𝐩𝐭𝐨𝐩 𝐋𝐢𝐧𝐤: web.reinforceqst.com/ 👉𝐌𝐲 𝐢𝐧𝐬𝐭𝐢𝐭𝐮𝐭𝐞 𝐚𝐩𝐩 𝐟𝐨𝐫 𝐈𝐎𝐒 𝐥𝐢𝐧𝐤: apple.co/3HFwBqo Org code : avywj 📧 Email : reinforceqst@gmail.com 🌐 Website : www.reinforceqst.com
@ramkrishnasarkar3935
@ramkrishnasarkar3935 10 ай бұрын
Is roof me crank bar que nahin diya gaya?
@mirsaif5795
@mirsaif5795 2 жыл бұрын
Sahi samjhaya Bhai...aap samjhao ge to aam aadmi bhi engeneer samjhe ga.👍
@chennareddyindla2349
@chennareddyindla2349 Жыл бұрын
Very very Good, Explained with live construction that is very important to get Idea.
@architectjitendrasharma4638
@architectjitendrasharma4638 Жыл бұрын
Thank you sir.Detail me samjhane k liye.
@abdulhakeem7663
@abdulhakeem7663 2 жыл бұрын
Thank u sir for sharing valuable information.
@hikikomorihachiman7491
@hikikomorihachiman7491 Жыл бұрын
Thank you very much sir.
@vipulsingh8647
@vipulsingh8647 2 жыл бұрын
गर्दा kr diya सर जी
@AshutoshKumar-pq9ud
@AshutoshKumar-pq9ud Жыл бұрын
Bahut acha samajh aya ❤
@mahabirsingh9278
@mahabirsingh9278 2 жыл бұрын
good video sir
@jatindhiman0200
@jatindhiman0200 8 ай бұрын
One question. Why crank bars and extra bars are not provided in the slab ?
@sandip02maisuriya95
@sandip02maisuriya95 2 жыл бұрын
Very good knowledge
@shivanjilpathak9186
@shivanjilpathak9186 Жыл бұрын
Why have you not hooked stirrups in 135 degree? None stirrups are visible to be bent at 135 degree with 10* dia hook or 75mm( which ever is greater)
@nikhilchauhan1074
@nikhilchauhan1074 2 жыл бұрын
Tqq sir
@RajKumar-vw6vi
@RajKumar-vw6vi 3 ай бұрын
Good 👍
@Damorhemuhimalaydamor
@Damorhemuhimalaydamor Жыл бұрын
Sir very nice video one more I am remember that
@chamanthakur2686
@chamanthakur2686 2 жыл бұрын
good 🙏
@harendrakumarchaudhary
@harendrakumarchaudhary 2 жыл бұрын
Good sir
@baburamesh9730
@baburamesh9730 Жыл бұрын
Good explanation sir
@Khan-oj8ds
@Khan-oj8ds 2 жыл бұрын
sir during construction bbi lana ek video please sir kya kya test hota hai... kese krate h pre construction list kya hoti during casting kya hota hai please sir🙏🙏🙏🙏🙏🙏
@thegodfather287
@thegodfather287 2 жыл бұрын
thannks great explanation .
@angomgunindrosingh9178
@angomgunindrosingh9178 Жыл бұрын
Please make a video on bottom reinforcement.
@chennareddyindla2349
@chennareddyindla2349 Жыл бұрын
Slab reinforcement, main and secondary bars are provided as mesh, why not provided crank bars or shear bars.
@abduljabbarabduljabbar9109
@abduljabbarabduljabbar9109 Жыл бұрын
Thanks Sir.
@sunilpandey6253
@sunilpandey6253 2 жыл бұрын
Thanks sir
@Arifaneesa-f9g
@Arifaneesa-f9g 9 ай бұрын
Nice
@sauravbasu1344
@sauravbasu1344 10 ай бұрын
Nice, what happens if the extra bars are different on either side of intermediate columns.
@kamleshgoyal9389
@kamleshgoyal9389 5 ай бұрын
Sir lapping zone ki video m btaya gya tha ki top m lapping centre pr dete hj ,ends pr nhi dete.shi kya h sir
@mallikarjuntandur
@mallikarjuntandur 2 жыл бұрын
hi, how to provide bent-up/ crank bar in two way continuous slab , i mean if the slab size is 40'x60' , there are many beams for support, my question is crank bar can be provided at only in end beams are cranked in every beam, if it is in every beam, rods length is in one length with overlapping or it may be cut sizes according to slab sizes
@civil915
@civil915 Жыл бұрын
Sir through out steel ja Raha wo column ki steel under Hona Chahiye
@manojmanojsahu4364
@manojmanojsahu4364 Ай бұрын
Sir primary beam Anchroge coloum development length coloum outer me hona chahiye but coloum ka center me provide kiya gaya hi videos me
@ReinforceInstitute
@ReinforceInstitute Ай бұрын
Is video banane k tym pe abhi steel arrangement fixing fully nhi huyi thi
@affansheikh2575
@affansheikh2575 2 жыл бұрын
At point where there is junction of primary and secondary beam but there is no column ( only junction of P beam & S beam) and ...do we have to provide extra top over there or else only continous steel is provided??
@chennareddyindla2349
@chennareddyindla2349 Жыл бұрын
Good question, but as there is no column no shear force comes. So not required extra bars where P and S beams junction.
@subhamthapa8113
@subhamthapa8113 2 жыл бұрын
what is to be done when the length of development length is still left even after providing 'L'..? should we insert the remaining part into the column or bent it towards beam..?
@hikikomorihachiman7491
@hikikomorihachiman7491 Жыл бұрын
I have learned on site that for those cases, we decrease the total length of column below it. Like for a 10’ column, we only cast 9’ column to accommodate the corresponding development length of beam that will be inserted in it.
@vimalkumarsingh8583
@vimalkumarsingh8583 2 жыл бұрын
Sir please send this drawing for better understanding
@Krishna-io7ie
@Krishna-io7ie 5 ай бұрын
Are Bhai sab ek bat btao ye Jo middle me column aarhe h ....inke liye extra steel cut krenge to l/4 k liye cutting length kaha se kaha tk lenge
@ReinforceInstitute
@ReinforceInstitute 5 ай бұрын
There are lots of videos we made regarding this check our full content properly!!
@KishanKumar-zh9ke
@KishanKumar-zh9ke Жыл бұрын
Sir Secondary beam me Top Extra bar dete hai ki nhi Agr dete h kitna ?
@MAnas-el6cd
@MAnas-el6cd Жыл бұрын
Bilkul dete hain as per drawing. Iss video me full detail mein checking ni ki hai sir ne. I have worked as an assistant Qc in Pakistan. There is also one thing missing in the video. Apne dekha hoga start walay beam me col ki 1 side py 3 extra thae aur dosre end py 4 extra this is because 2 different beams hain aur jahan per cols k sath 2 beams ayein tou jis ka extra bars ziada hote hain usy hum L/3 per lete haim iss liye dosre end per 3 ki jagah 4 extra liye bars.
@rakeshraturi1435
@rakeshraturi1435 Жыл бұрын
Sir extra bar sirf top per hi daalte hai ki bottom me v
@ReinforceInstitute
@ReinforceInstitute Жыл бұрын
Btm mai v
@pankaj6423
@pankaj6423 2 жыл бұрын
👌👌👌👍👍👍sir
@ramakumargupta7485
@ramakumargupta7485 Жыл бұрын
Sir ring ka hook galt hai 135 digri me baniye
@truegaming5515
@truegaming5515 Жыл бұрын
Sir ring ki band 35' nahi hai
@zafarsk1183
@zafarsk1183 2 жыл бұрын
Secondary Bheem ka details nahin bataya
@hizbulllahkhattak2184
@hizbulllahkhattak2184 2 жыл бұрын
Slab ka bato extra baar
@Krishna-io7ie
@Krishna-io7ie 5 ай бұрын
Jo concept smghne k liye mne video dekha uska answer to Mila hi nahi yr😂
@ReinforceInstitute
@ReinforceInstitute 5 ай бұрын
50 se jyda video hai playlist check krein humara
@makdumshaikh2686
@makdumshaikh2686 2 жыл бұрын
s
@royalgaming7085
@royalgaming7085 2 ай бұрын
43o
@umrannadafnadaf6108
@umrannadafnadaf6108 7 ай бұрын
Not useful
@beingafzystar1504
@beingafzystar1504 Жыл бұрын
Aaapke slab ka bent-up kaha hai😁😁
5 Important Rules of Beam Design Details | RCC Beam | Green House Construction
8:45
NHÀ XANH VIỆT NAM
Рет қаралды 2,2 МЛН
How to Check Beam Reinforcement at Site | Beam Checking Important Tips for Engineer | By CivilGuruji
18:12
Spongebob ate Michael Jackson 😱 #meme #spongebob #gmod
00:14
Mr. LoLo
Рет қаралды 11 МЛН
Running With Bigger And Bigger Lunchlys
00:18
MrBeast
Рет қаралды 125 МЛН
Understand the Arrangement of Reinforcement |Why L/3 L/4 0.25L 0.3L | Why Top Extra Why Bottom Extra
15:16
How to read beam reinforcement drawing | typical beam reinforcement details
10:41
SLAB Reinforcement Details, लोहा कैसे लगाते है. Must Watch #civilguruji
24:48
Continuous Beam Reinforcement according to Curtailment
4:10
AK Skills & Solutions
Рет қаралды 655 М.
Two Way Slab Reinforcement
9:08
AK Skills & Solutions
Рет қаралды 949 М.
Spongebob ate Michael Jackson 😱 #meme #spongebob #gmod
00:14
Mr. LoLo
Рет қаралды 11 МЛН