How to make an Earthing at home | Earthing connection for home

  Рет қаралды 1,113,819

BEEE Works

BEEE Works

Күн бұрын

#beeeworks #electricalwork #wiring
Hello Friends ! Welcome back to our channel. I hope this video may helps you 😊
🔴 Red wire = Phase
⚫ Black wire = Neutral
🟢 Green wire = Earthing
🔷Like 🔷Share 🔷Comment 🔷Subscribe
___________________________________________________
⚫ Follow us🔻
🔶 KZbin -1
/ @megaelectricals
🔶 KZbin -2
/ beeeworks
🔶 Instagram
/ beee.works
___________________________________________________
⚠️ WARNING...❗
This video is only for educational purpose. High voltage can damage your life. Some works can be Dangerous. And for that, you dont risk and damage your self. Iam a professional in my work. You should take care or precautions before attempting the experiment or work.
___________________________________________________
🔷 For Business Quarys🔻
💌 beeeworks.official@gmail.com 😊
___________________________________________________

Пікірлер: 344
@BEEEWorks
@BEEEWorks 4 жыл бұрын
Earthing for home. beeehacks.blogspot.com/2021/02/earthing.html
@tarunjaiswal260
@tarunjaiswal260 3 жыл бұрын
You have not used water to settle fown everything
@tarunjaiswal260
@tarunjaiswal260 3 жыл бұрын
in between the procedure
@naturetruth5218
@naturetruth5218 2 жыл бұрын
Shouldn't mislead others into getting electrocuted with half baked sharing and bare hand testing live wire. Because using low wattage bulb of 15~30W testing, the current flowing is very low below 0.15A. Per my own past experience and some research, a proper earthing require minimum (those who know better pls correct my mistake if any): 1) Nailed a solid earth rod of min 1.5cm diameter & 2m length (min depth of 1.8m inside earth). If you can drill a 2m hole, then using big hollow rod does give a better surface area. 2) Thick copper wire of 6mm standard and 3 copper threads type (the one in video look 1.5mm and is multi fine threads, easily oxidized over time). The thicker is better for safety say 6mm if to connect from earth rod to main earth point for entire home (internal earth wire laying can be 1.5~2.5mm). 3) Salts and charcoals are meaned to absorb water moisture to improve earth conductivity surface with the soil, esp if its sandy & not good clays. Adding sands is increase porous for water flowing only, as sands are not good in conductivity. So you need to locate the earth rod around constant moisture area such as water drainage, or need to wet the area regularly in dry summer to ensure the earth rod function well. 4) Using 3pts earth measuring meter to ensure the earth resistance is below 5 ohms, preferably 2ohms. If you can't get below that, add extra same earth rod (min 1.8m away to avoid overlapping earth zone). This will reduce resistance by approximately half. Add until you get below 5ohms. 5) If you have no access to proper earth measuring meter that cost $100~300, use a 100watts light bulb to test(current flow of 2.2A). It should light up brightly with one end connect to 110/220V live wire, the other to the earth wire. Using 15w bulb testing is useless since current flow is below 0.1A). Ideally the earth wire must able to divert away 10~20A current, so I used a 2KW kettle to test boiling water and measure the current flow using a clipper ammeter clip on wire. If the power supply voltage is 220V, current is 9A, then the earthing is quite ok. If you don't have clipper ammeter, use P=VI, Current I = 2000W /220V=approx 9A if the kettle boil like normal (if very slow means earthing is weak, current may be only 1~5A) showing not ok. Or you can measure Vk, the voltage drop between kettle two wire ends, I=Vk/R=Vk/25. Using P=VI, R=V/I, you can estimate the resistance of earth by: Rt=R1 + R2, where Rt is total resistance seen from current input, R1 is kettle heating coil resistance (R1=V/I=V²/P=220²/2000=24.2, ~25ohm), R2 is earth resistance. Rt= V/I. V= voltage drop between power supply (220V) and the earth. Vt=V1 + V2, where Vt=Total voltage=220V, V1=voltage drop between kettle two wire ends, V1=IxR=25I. So V2=220 - V1(assume your power supply is stable, usually it will drop for poor country to even 120~180V). That say we get 8A flowing through the kettle, V1=200v, R2=V2/I=(220-200)/8=2.5ohms. That's acceptable close to ideal below 2ohms. If I=5A, R2=(220-5x25)/5=19ohms. Need to add another few earth rods connect in parallel to reduce it to below 5ohms. 1/Rt=1/R1 + 1/R2 + …1/Rn. Usually bad earth will give I=2A that can still light up 60W bulb well, R2=(220-2x25)/2= 85 ohms. The one in the video is likely to be around 50~300 ohms. Usually those need to make own earth point live in rural area with poor power supply. So Vt will be a fluctuating variable under loading requiring meter measuring for accuracy. Hence engaging a qualified electrician is better if you have no capability than to regret later.
@newtonkdl
@newtonkdl 9 ай бұрын
@@naturetruth5218😮
@mallikabhandary3234
@mallikabhandary3234 3 жыл бұрын
অনেক কিছু জানা গেলো।ধন্যবাদ।
@sangamitraiashok2850
@sangamitraiashok2850 11 ай бұрын
Every information is useful. When you are making a video you must be careful. The bolt nut used are very old. It should be new, because we are not going to service it in the near future. But your service is good. Thank you
@yank3656
@yank3656 3 жыл бұрын
thanks for sharing BEEE Works
@lutherkalmel463
@lutherkalmel463 3 жыл бұрын
Supper first time I Saw understood about this thank you so much
@KalaloIsmael
@KalaloIsmael Жыл бұрын
Masha Allah tabarak Allah it's amazing 😍
@AyeshaVillamor-n3t
@AyeshaVillamor-n3t Жыл бұрын
Can it take big load like AC and Ref?
@BEEEWorks
@BEEEWorks Жыл бұрын
Yes
@atananggodwinetim
@atananggodwinetim 11 ай бұрын
Thanks for making the he video. Gave me a clue on how to go about mine.
@NXP-n2r
@NXP-n2r Ай бұрын
Very good thats science ❤
@prasadarao2826
@prasadarao2826 2 жыл бұрын
Very nice video brother
@TerrycoolAdams
@TerrycoolAdams Жыл бұрын
That is very good of you Sir
@naturetruth5218
@naturetruth5218 2 жыл бұрын
Shouldn't mislead others into getting electrocuted with half baked sharing and bare hand testing live wire. Because using low wattage bulb of 15~30W testing, the current flowing is very low below 0.15A. Per my own past experience and some research, a proper earthing require minimum (those who know better pls correct my mistake if any): 1) Nailed a solid earth rod of min 1.5cm diameter & 2m length (min depth of 1.8m inside earth). If you can drill a 2m hole, then using big hollow rod does give a better surface area. 2) Thick copper wire of 6mm and 3 copper threads type (the one in video look 1.5mm and is multi fine threads, easily oxidized over time). The thicker is better for safety say 6mm if to connect from earth rod to main earth point for entire home (internal earth wire laying can be ~2.5mm). 3) Salts and charcoals are meaned to absorb water moisture to improve earth conductivity surface with the soil, esp if its sandy & not good clays. Adding sands is increase porous for water flowing only, as sands are not good in conductivity. So you need to locate the earth rod around constant moisture area such as water drainage, or need to wet the area regularly in dry summer to ensure the earth rod function well. 4) Using 3pts earth measuring meter to ensure the earth resistance is below 5 ohms, preferably 2ohms. If you can't get below that, add extra same earth rod (min 1.8m away to avoid overlapping earth zone). This will reduce resistance by approximately half. Add until you get below 5ohms. 5) If you have no access to proper earth measuring meter that cost $100~300, use a 100watts light bulb to test(current flow of 2.2A). It should light up brightly with one end connect to 110/220V live wire, the other to the earth wire. Using 15w bulb testing is useless since current flow is below 0.1A). Ideally the earth wire must able to divert away 10~20A current, so I used a 2KW kettle to test boiling water and measure the current flow using a clipper ammeter clip on wire. If the power supply voltage is 220V, current is 9A, then the earthing is quite ok. If you don't have clipper ammeter, use P=VI, Current I = 2000W /220V=approx 9A if the kettle boil like normal (if very slow means earthing is weak, current may be only 1~5A) showing not ok. Or you can measure Vk, the voltage drop between kettle two wire ends, I=Vk/R=Vk/25. Using P=VI, R=V/I, you can estimate the resistance of earth by: Rt=R1 + R2, where Rt is total resistance seen from current input, R1 is kettle heating coil resistance (R1=V/I=V²/P=220²/2000=24.2, ~25ohm), R2 is earth resistance. Rt= V/I. V= voltage drop between power supply (220V) and the earth. Vt=V1 + V2, where Vt=Total voltage=220V, V1=voltage drop between kettle two wire ends, V1=IxR=25I. So V2=220 - V1(assume your power supply is stable, usually it will drop for poor country to even 120~180V). That say we get 8A flowing through the kettle, V1=200v, R2=V2/I=(220-200)/8=2.5ohms. That's acceptable close to ideal below 2ohms. If I=5A, R2=(220-5x25)/5=19ohms. Need to add another few earth rods connect in parallel to reduce it to below 5ohms. 1/Rt=1/R1 + 1/R2 + …1/Rn. Usually bad earth will give I=2A that can still light up 60W bulb well, R2=(220-2x25)/2= 85 ohms. The one in the video is likely to be around 50~300 ohms. Usually those need to make own earth point live in rural area with poor power supply. So Vt will be a fluctuating variable under loading requiring meter measuring for accuracy. Hence engaging a qualified electrician is better if you have no capability than to regret later.
@graceify2908
@graceify2908 Жыл бұрын
Please what are the disadvantages?
@sopanpalake1668
@sopanpalake1668 3 жыл бұрын
Good 👍
@Rajesh_108
@Rajesh_108 3 жыл бұрын
Thanks friend ❤👍
@mukeshmajhi7061
@mukeshmajhi7061 3 жыл бұрын
Awesome video
@sayandatta1974
@sayandatta1974 3 жыл бұрын
Nice👍👍👍👍👍
@poonambhatt292
@poonambhatt292 3 жыл бұрын
Sir this is amazing video
@ravitupe8921
@ravitupe8921 3 жыл бұрын
Nice video
@vivekroy4u
@vivekroy4u 3 жыл бұрын
Nice video 👍
@andrewm8831
@andrewm8831 2 жыл бұрын
Interesting video, I didn't realise you had to apply so much water at the moment I,am going through a grounding phase,🤣in my home, this includes my sky dish, hi fi rack,amplifier outer body,refrigerator etc yes I know some of these items are already earthed but it's only when you apply extra grounding you realise how minimal earthing is on some appliances
@qaziqalander
@qaziqalander 3 жыл бұрын
Dear Sir, Very simple practical explanation, Sorry I couldn't see all utilized items details& their quantities. Plz review if the background music is substituted with narration in English! It will be a good idea if earthing arrangement's capacity is told. Additionally it's for AC or DC use! Thanks in advance
@viswanathancr2801
@viswanathancr2801 3 жыл бұрын
good video
@gohilraj9017
@gohilraj9017 3 жыл бұрын
Best vdo thanks to save my money
@aap99alalawy
@aap99alalawy Жыл бұрын
Coal or charcoal?
@BEEEWorks
@BEEEWorks Жыл бұрын
Charcoal
@NaseemKhan-tv7un
@NaseemKhan-tv7un 7 ай бұрын
Very nise❤🎉f Khan karachi pakistan🎉🎉🎉
@saurabhshete3441
@saurabhshete3441 2 жыл бұрын
Thanks bhaiyya
@ruatarengsicolneyrengsi8924
@ruatarengsicolneyrengsi8924 2 жыл бұрын
Very clear presentation. Many thanks.
@prasannaanurasiri2548
@prasannaanurasiri2548 2 жыл бұрын
salt increases both pipe and earth conductivity but my problem is salt is a very corrosive material then one-day malfunctioning earthing system. so we have to change this system regularly.
@BEEEWorks
@BEEEWorks 2 жыл бұрын
Good
@dumbuyaelbowmusa4104
@dumbuyaelbowmusa4104 Жыл бұрын
Thank you for sharing this knowledge with us
@varahiviews4385
@varahiviews4385 Ай бұрын
We should use single stand copper wire atleast 2 mm thickness
@gauravchauhan8205
@gauravchauhan8205 3 жыл бұрын
Good
@GauriTiwari-zc2so
@GauriTiwari-zc2so 3 сағат бұрын
Is anyone from class 10th 😁😁
@rajumgiger09
@rajumgiger09 5 ай бұрын
Nice
@Goodlifeleave
@Goodlifeleave 3 жыл бұрын
Video achha hai Par music ke alava aap kuch bolte to achha lagta 😊
@aswinisamantray
@aswinisamantray 3 жыл бұрын
Yes very easy process...thanks.
@BEEEWorks
@BEEEWorks 3 жыл бұрын
👍👍👍
@kishoreKumar-wt4vi
@kishoreKumar-wt4vi 3 жыл бұрын
Good post sir. When doing time explain is good I think sir.
@kaliannanperiannan4747
@kaliannanperiannan4747 2 жыл бұрын
இந்த முறையில் நல்ல Earthing கிடைக்காது!!! காப்பர் பிளேட்+ காப்பர் பட்டை + GI பைப் கொண்டு எர்த்திங் செய்வதே சிறந்தது. உரிய விளக்கம் தேவை!!! நன்றி வணக்கம் வாழ்த்துக்கள்.
@nagarjunareddymorgadi4787
@nagarjunareddymorgadi4787 3 жыл бұрын
Super
@krishnabilthare3059
@krishnabilthare3059 2 жыл бұрын
Y no aapne sand dala hai y kya cheez hai ji please jarur bataye apka y earthing banane ka tareeka bahut hi achha hai
@hawbashjabar2005
@hawbashjabar2005 5 ай бұрын
nice
@michaelandew8266
@michaelandew8266 2 жыл бұрын
Salt and charcoal increase the conductivity of the soil in the earth pit. But we should not directly use salt inside the pipe as it will make rust and damage the pipe. As a result the longibity and life of the pipe will reduce.
@BEEEWorks
@BEEEWorks 2 жыл бұрын
Pipe is not stable, besides copper will stable
@peterchanda303
@peterchanda303 Жыл бұрын
You are very right
@venom-kc7ri
@venom-kc7ri 11 ай бұрын
use pvc pipe, copper board and copper wire 5mm
@ganesharer6887
@ganesharer6887 7 ай бұрын
Law amount items it's good 👍👍👍👍👍👍👍👍
@yahcobyisrael3000
@yahcobyisrael3000 Жыл бұрын
That’s dope 💯
@TolenyabiIstifanus
@TolenyabiIstifanus Жыл бұрын
Nice work
@sujeetpremikumar1411
@sujeetpremikumar1411 3 жыл бұрын
Super Bhai
@commandernoodles2367
@commandernoodles2367 Жыл бұрын
I still need to understand what you are doing? I would appreciate it better if you gave explanations. Good video.
@akshaysantra2764
@akshaysantra2764 3 жыл бұрын
Thank you 🙏🙏🙏👌👌
@Gopothik
@Gopothik Ай бұрын
Copper use is good
@rogeriobastosbastos5942
@rogeriobastosbastos5942 2 жыл бұрын
Good. With a low power equipment it works. " More if you put a power in ( W ). Greater can cause the loss of equipment... Att,,
@bhaskardeka1601
@bhaskardeka1601 4 жыл бұрын
Thanks sir 👍👍👍👍
@KESAVANAs-xu6yb
@KESAVANAs-xu6yb 4 жыл бұрын
Good jop !!!.....
@aswinisamantray
@aswinisamantray 3 жыл бұрын
Today I have done my earthing as per your direction. One 4mm 2 meter cupper wire rape on the 5feet GI pipe of 40mm dia cost.350 with bolt and nuts on top and bottom/. 2 tin charcoal cost..100/ salt.13kg..cost.100 rupees Sand one ciment bag cost..20/ labour cost.250/ ..so total . cost.. approximately 850/ . checked earth come within 5 minutes. Many many thanks..
@BEEEWorks
@BEEEWorks 3 жыл бұрын
Thanks for ur feedback sir.
@sudalaimadan6261
@sudalaimadan6261 3 жыл бұрын
super
@K1LLA_KING_KONG
@K1LLA_KING_KONG Жыл бұрын
im not sure everyone does it this way, most just hammer a copper rod in. However adding the salt would be benificial by adding electrlytes to imrove conductivity
@sushilkamble3124
@sushilkamble3124 4 ай бұрын
👌💐🙏👍
@richardsaunders2464
@richardsaunders2464 Жыл бұрын
Nice video, what type of coal and rock salt did you use?
@BEEEWorks
@BEEEWorks Жыл бұрын
Charcoal and large size cooking salt
@LEROi-kq5ty
@LEROi-kq5ty 3 жыл бұрын
Il faut tester la différence de potentiel entre la phase et cette fil de terre par un voltmètre et si la tension est 220v donc l installation électrique est sécurisée
@fachushabi
@fachushabi 3 жыл бұрын
Wrong. atleast use 14swg coopper.pipe length 2meter. Clear nut bolt.
@rajputsingh9465
@rajputsingh9465 Жыл бұрын
Plz dont use lamp testing time led bulb
@igh1785
@igh1785 3 жыл бұрын
I'm like can I have the recipe please. Oh, it's already on the video! 🤣 nice cook, man!
@munnalalgupta1803
@munnalalgupta1803 2 жыл бұрын
कम खर्चे में बनी अर्थिंग 😊😊😊😊😊😊😊😊
@raviyadav8743
@raviyadav8743 3 жыл бұрын
अच्छा होता अगर आप 100w बल्ब जलाते तो पता चलता की तेज जल रहा है या कम LED में बराबर पता नही चलेगा ,अर्थिंग मजबूत है या नही।
@BEEEWorks
@BEEEWorks 3 жыл бұрын
U means led bulb was low power consumption hence it should glow. Of course 60 watts bulb also glow but glow with low voltage due to earthing is not act as pure neutral wire so it will supply low voltage between line and neutral Hence the 60watts bulb glow with low of light (dim)
@raviyadav8743
@raviyadav8743 3 жыл бұрын
@@BEEEWorks I mean to say if you use earthing for neutral purpose , so how we check with bulb ( how much Watt) for proper neutral
@BEEEWorks
@BEEEWorks 3 жыл бұрын
60w or 100watts GLS bulb is best one to check proper Earthing. Thanks for clear your doubt 😍
@raviyadav8743
@raviyadav8743 3 жыл бұрын
@@BEEEWorks so,in proper nutral bulb should be glow bright or dim Just make is clear bro.
@BEEEWorks
@BEEEWorks 3 жыл бұрын
Dim
@a.p.sarkar3967
@a.p.sarkar3967 10 ай бұрын
Instead of using rusted iron bolt & nut . use copper nut -bolt
@BEEEWorks
@BEEEWorks 9 ай бұрын
Sure
@RRR76515
@RRR76515 Жыл бұрын
Will it work properly..... Please tell me...... I have done it for boiler...... Now..... Is it safe.... Then i will start
@CB.Shine_rider
@CB.Shine_rider 3 жыл бұрын
I like it bro thank you❤🌹
@maeteves1393
@maeteves1393 3 жыл бұрын
There’s no conduction, bolt is very rustl
@aiqkhan3283
@aiqkhan3283 2 жыл бұрын
Kanjoos hy loru
@skt3510
@skt3510 2 жыл бұрын
Yes
@urandurparthu1526
@urandurparthu1526 2 жыл бұрын
Bulb is glowing thought
@kartikeyagupta7938
@kartikeyagupta7938 2 жыл бұрын
@@urandurparthu1526 this is led bulb if you connect halogen bulb it will glow but dim
@BEEEWorks
@BEEEWorks 2 жыл бұрын
Yes, because low voltage
@mickvibes7607
@mickvibes7607 3 жыл бұрын
Its good to test with 100watt bulb....to know the resistance of earthing
@BEEEWorks
@BEEEWorks 3 жыл бұрын
Yes
@kandasamyathanursengottuve6849
@kandasamyathanursengottuve6849 3 жыл бұрын
earth electrode resistance of an earth pit in a house has to be below 5 ohm . by measuring with an earth megger it should be below 5 ohms at any time and then only it shall be claimed a good earthing . kindly go through the author's text book titled electricity- theory and practice for more and detailed earthing published by AMITY UNIVERSITY PRESS NEW DELHI
@mamoonahmed-k5s
@mamoonahmed-k5s 5 ай бұрын
sir g tamaq na kra doyo kate🪔
@Ytl-x8d
@Ytl-x8d 4 ай бұрын
Can we use aluminium cable & aluminium rod for earthing?
@brendonshane7904
@brendonshane7904 Жыл бұрын
u must use cooper pole instead of steel..because steel much easier to rust
@BEEEWorks
@BEEEWorks Жыл бұрын
Yes, ur correct
@marioarteta6863
@marioarteta6863 Жыл бұрын
Where did the other red wire came from
@BEEEWorks
@BEEEWorks Жыл бұрын
From socket
@madhavmohite4158
@madhavmohite4158 2 жыл бұрын
🔥
@bungakotibabu5368
@bungakotibabu5368 Жыл бұрын
Without copper plate, no problem
@secrets873
@secrets873 2 жыл бұрын
২ ঘোড়া মোটর চালানোর জন্য বিদ্যুতের খুঁটি থেকে আর্থিং লাইন নাইনে নিজে কিভাবে আর্থিং লাইন বানাতে পারবো❓❓
@abdulkhayum961
@abdulkhayum961 Жыл бұрын
Bogu Shasta mix I Tay amitade
@nituchangmai6538
@nituchangmai6538 Жыл бұрын
It should not use Salt because the iron pipe and salt make a chemical reaction and as a result the rust produced and the pipe will be damaged within a few months..The salt could be use only hilly place where water level is very low,the wire size is too much thin which use by you for proper work
@ramuelectricalknowledge8589
@ramuelectricalknowledge8589 4 жыл бұрын
200w bulb petti chek cheyandi appudu pakka unnattu earth
@sidiubari745
@sidiubari745 Жыл бұрын
Earthing se pc,ups nahi calta hai???❤️❤️❤️❤️❤️
@rajibbasumatary1280
@rajibbasumatary1280 3 жыл бұрын
I don't think you have installed it in right way. You used corroded bolt which will provide bad conductivity. Secondly the insulator of wire came in between pipe and washer, so there is not good contact between pipe and the wire.
@kuthalaravi3433
@kuthalaravi3433 2 жыл бұрын
-7.2.1 What is Earthing weak insulation, element breakage and the like. The device consists of a copper or GI wire that comes out Earthing is a very important safety device that is used to prevent shocks caused by leakages arising from of an electrode. Earthing is placed 2.5 to 3 meters underground. The potential of earth is always assumed to be zero. Electrical equipment is said to be earthed when it is added to the wire. 🖤
@damodarsingaram
@damodarsingaram 3 жыл бұрын
this is Old model, Now chemical available Copper rod is the best.
@Daksh_Kahar_gaming
@Daksh_Kahar_gaming 2 жыл бұрын
Wire me Pani dalne se current to nahi aata 🤔?
@kamauwakimani4493
@kamauwakimani4493 Жыл бұрын
Does it has to hang on the ground surface like that?
@pruthvirajkoli1900
@pruthvirajkoli1900 Жыл бұрын
It is working for single phase water pump..?
@BEEEWorks
@BEEEWorks Жыл бұрын
Yes
@AtoPangwai-nj8oh
@AtoPangwai-nj8oh Жыл бұрын
How many feet long pipe we used for earthing?
@sarkarpaban_official655
@sarkarpaban_official655 3 жыл бұрын
Jala hua koyla ya bina jala hua
@deomugisha941
@deomugisha941 Ай бұрын
But you didn't tell amount you use
@JourneywithIndianRailway
@JourneywithIndianRailway Жыл бұрын
Which coal do u use wood coal or stone
@riyanc-musicentertainments8367
@riyanc-musicentertainments8367 3 жыл бұрын
Is good this method for house wiring Earth????? is there not danger because Neutral path coming from earth??????? Reply pls sir!
@BEEEWorks
@BEEEWorks 3 жыл бұрын
Yeah, it's good earthing. There is no dengerous.
@directattachmentwithland6961
@directattachmentwithland6961 6 ай бұрын
This could be workable for equipment earthing but not enough robust for lightning arrester .
@franckherrmannsen7903
@franckherrmannsen7903 2 жыл бұрын
you might want to make a three point resistance measurement through dry earth with lower resistance than 3 Ohms to not get electrocuted, i estimate the the length of 1" pipe at least 5m depending on quality of your soil, then you take two earthnails around 30cm length in a distance of about 5 and 10m, if above 3 Ohm add another 2 m on top, or put another 5m next to the first and connect them until you´re good
@BEEEWorks
@BEEEWorks 2 жыл бұрын
Great information
@bibekshrestha4740
@bibekshrestha4740 Жыл бұрын
Earthing kitna area tak safe hota hai
@sarkarpaban_official655
@sarkarpaban_official655 3 жыл бұрын
Yeh coyla konsa hai jala hua ya bina jala hua
@partymanau
@partymanau Жыл бұрын
Could u find a rustier bolt?
@ceylonreports
@ceylonreports 3 жыл бұрын
👍👍👍
@GanshuDravid
@GanshuDravid 4 ай бұрын
Sir how much deep required to earthing as you mentioned 2 meter is it fine.. Advice please 🙏
@punitmehrol2024
@punitmehrol2024 3 жыл бұрын
Bhai copper ke nutbolt lete hai aapne to rusted liye hai
@ajaysharma9939
@ajaysharma9939 3 жыл бұрын
Hi, can I make the pipe earthing near my plastic water tank ? Will it be safe? Please reply
@naulalzustyn5425
@naulalzustyn5425 2 жыл бұрын
Ok
@sitangshupayra1954
@sitangshupayra1954 2 жыл бұрын
Use steel bolt for longlife
@BEEEWorks
@BEEEWorks 2 жыл бұрын
Sure,
Stages of home grounding installation to avoid electrocution
5:22
Benbaslec12
Рет қаралды 1,4 МЛН
To Brawl AND BEYOND!
00:51
Brawl Stars
Рет қаралды 17 МЛН
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 31 МЛН
Quando A Diferença De Altura É Muito Grande 😲😂
00:12
Mari Maria
Рет қаралды 45 МЛН
What is Ground? Earth Ground/Earthing
9:27
RimstarOrg
Рет қаралды 3,2 МЛН
I turn Water into a Free Lifetime Cooking Gas, Free Gas
15:31
I Turn it
Рет қаралды 808 М.
Helpful 6 electronics projects you can make at home.
8:04
Inventor AW
Рет қаралды 526 М.
The World's Maximum Security Prison: CECOT (The most evil are kept here)
20:52
How To Install An Electrical Earthing (Easy Way)
18:25
TOPHEIGHTS ELECTRICIANS, PLC
Рет қаралды 61 М.