Best Dental Compressor | How to Solve a Dental Air Compressor Problem | Silent Air Dental Compressor

  Рет қаралды 15,424

Krishna Kumar Shrestha

Krishna Kumar Shrestha

Күн бұрын

Пікірлер: 36
@dr.mahendrapalsain5418
@dr.mahendrapalsain5418 11 ай бұрын
Start hone meproblem ho .kya mistake ho skti h. Kya condenser cell change k jarurat hogi?
@erkrishnakumarshrestha
@erkrishnakumarshrestha 11 ай бұрын
Please do the following: 1. AC voltage ( should be: 210-230volt). if the voltage range is ok, then 2. Change the condensor / capacitor of 25uf /400volt 3. If the step 2. does not work, then Please contact to the motorwinding mechanic.
@rewashrivastav9607
@rewashrivastav9607 2 күн бұрын
Sir chair ma jaane indicator ful red ma garsakyl tara compressor ma air pugeko xaina vhane kei prob xaina ni?
@erkrishnakumarshrestha
@erkrishnakumarshrestha 4 сағат бұрын
Please follow the following steps: There are two Pressure gauze in the Compressor. 1. pressure Gauze ( Large) : it measures the Air Inside / inner / compressor tank Air Pressure. Cut out pressure ( Auto Stop point : 8 bar and Cut In ( Aut Start point): 4 bar. Please check this phenomenon first. 2. Sometimes the compressor stops running before 4 or 5 bars. At that time please check the Electricity Power supply voltage. 3. If the above two methods/points are ok, But Tanky pressure is not increasing above 5 bar, Head motor is continuously running. Then Change the Compressor motor head. 4. If the compressor motor stops when Tank pressure Gauze needle is reached to 5 or less than it. Then adjust the Auto cut system ( Small black box ) to increase the tank pressure. There is another Pressure Gauze ( Small) with Moisture Trapper: 1. Maximum Pressure we can deliver to chair is 6 bar. The Dental chair pipe pressure capacity can hold this pressure. We can adjust from its adjuster given to the top. Thank you.
@rewashrivastav9607
@rewashrivastav9607 2 күн бұрын
Arko indicator ko k kaam ho
@Dentist-ne7bo
@Dentist-ne7bo 11 сағат бұрын
How to reduce the noise? Please help
@erkrishnakumarshrestha
@erkrishnakumarshrestha 4 сағат бұрын
Sir, there are few methods to reduce the noise. 1. Air Intake Filter: Please check this filter. If the air filter is ok then 2. Head ( Motor ) : Please change the compressor Head ( Motor ). If your Compressor has been running for the last 3 years then I recommend changing the motor head. Or 3. Install the compressor Away from the procedure room. or outside of the Dental chair room. Connect the air by Piping. Thank you so much sir for your inquiry.
@hellangel230
@hellangel230 11 ай бұрын
Compressor ma dental unit ko delivery pipe kasari fit garne ani washer bigryo bhane paucha ??
@hellangel230
@hellangel230 11 ай бұрын
REgulator bata hawa jane pressure kati hunu parcha hajur?
@erkrishnakumarshrestha
@erkrishnakumarshrestha 11 ай бұрын
6 baar pressure when the compressor is full. Pressure will decrease while working on the chair. When Pressure decreases to 4 baar, the compressor will automatically start. And stops when it reaches 8 baar.
@hellangel230
@hellangel230 11 ай бұрын
@@erkrishnakumarshrestha 13.26 tyo regulator niskyo bhane how do we fix back? it seems that my regular cap has come off !
@reyazahmed1780
@reyazahmed1780 Жыл бұрын
How to connect tube to compressor, kindly help
@erkrishnakumarshrestha
@erkrishnakumarshrestha Жыл бұрын
Thank you sir. To connect the tube or Air Pipe, you need a plier to do so. I will post another video regarding this issue also.
@ku.bhavanisinghrathorerath6546
@ku.bhavanisinghrathorerath6546 2 жыл бұрын
Mera compresure awaj bhut kr ta h jor se bjta h kese thik kru
@erkrishnakumarshrestha
@erkrishnakumarshrestha 2 жыл бұрын
Please replace the Compressor Piston set or Compressor Head.
@aliawan021
@aliawan021 Жыл бұрын
how to control noise
@erkrishnakumarshrestha
@erkrishnakumarshrestha Жыл бұрын
Sir, noise comes from the Dental air compressor if the Motor is very old like 2 or 3 years later. Another reason is, the air input filter also helps to reduce the noise.
@aliawan021
@aliawan021 Жыл бұрын
@@erkrishnakumarshrestha thanks one video plz
@sunilkarki5738
@sunilkarki5738 2 жыл бұрын
thank you very much for your precious information sharing ,it means a lot to us :)
@erkrishnakumarshrestha
@erkrishnakumarshrestha 2 жыл бұрын
Welcome.
@ambikadhakal1639
@ambikadhakal1639 Жыл бұрын
Impressive !!
@altimadentalcentre7880
@altimadentalcentre7880 2 жыл бұрын
Dental chair 5-6 mae off ho ja rahi hae...
@erkrishnakumarshrestha
@erkrishnakumarshrestha 2 жыл бұрын
There might be a problem on electric power supply. Power supply voltage might be low. Second reason can be of the Cut-off system.
@altimadentalcentre7880
@altimadentalcentre7880 2 жыл бұрын
Ok rhankyou
@md.litonahmedmd.litonahmed8246
@md.litonahmedmd.litonahmed8246 Жыл бұрын
Price
@dr.kaustavpramanik9396
@dr.kaustavpramanik9396 8 ай бұрын
please make it in Hindi.
@erkrishnakumarshrestha
@erkrishnakumarshrestha 8 ай бұрын
Ok
@MJFurniture-vg4zo
@MJFurniture-vg4zo Жыл бұрын
मेरो मा पनि यस्तै compreesor छ तर हावा धेरै kam दिदैछ kea6 यसको उपाय
@erkrishnakumarshrestha
@erkrishnakumarshrestha Жыл бұрын
Thank you sir for the comment first. I think, there are two options: Please check the first thing is: 1. ) Air Filter: It may be filled with lots of Dust. Please clean it first. After that please re-install in the same place. Does it work? If air fill up time is very short then its alright. 2.) The second and last option is: Needs to replace the Compressor motor head.
@macadv736
@macadv736 6 ай бұрын
I wish this was english
@erkrishnakumarshrestha
@erkrishnakumarshrestha 6 ай бұрын
Ok sure. I will upload in English in the coming days.
@Smileawhile_23
@Smileawhile_23 Жыл бұрын
Compressor bata achanak thulo aawaj ma hawa gayo. Sabai hawa nasakinjel awaaj thulai aayera hawa gayo ahile compressor chaleko xaina k vayeko hola kasari samadhan garna sakinxa?
@erkrishnakumarshrestha
@erkrishnakumarshrestha Жыл бұрын
Please find out the location from where the air leakage is. Possible air leakage area : - Solenoid valve - The drain gate valve at the bottom of the compressor might be open. If it is open, close it please by moving 90° right clockwise. - If not solved, please do whatsapp / viber / video call at : +977- 9851142296
@msknsng9476
@msknsng9476 Жыл бұрын
Sampark kaise kare mobile no
@erkrishnakumarshrestha
@erkrishnakumarshrestha Жыл бұрын
+977-9851142296 Nepal
Sigma Kid Mistake #funny #sigma
00:17
CRAZY GREAPA
Рет қаралды 30 МЛН
How Strong Is Tape?
00:24
Stokes Twins
Рет қаралды 96 МЛН
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 158 МЛН
HOW TO REPLACED AIR FILTER REGULATOR!!!!
12:15
J.B Dental chair Repair Vlogs
Рет қаралды 718
تعلم صيانه الكمبروسور للمهندس حسام الدين
11:06
Applied Medical Science Bio-Medical Engineers
Рет қаралды 9 М.
Finally! I Found the Perfect Budget Knife!
20:59
Project Farm
Рет қаралды 517 М.
Una compresora que carga a 150 psi peligrosa ?
13:43
Día a día con Ulises Constantino
Рет қаралды 17 М.
Amazing Hydraulic Press!! Powerful DIY Hydraulic Press!!
15:51
KEVGEN MASTER
Рет қаралды 33 М.
Centralized Suction System
2:32
sachin shetty
Рет қаралды 95 М.
Sigma Kid Mistake #funny #sigma
00:17
CRAZY GREAPA
Рет қаралды 30 МЛН