Your explanation awesome showing the Live Mistakes are True
@rahuldatta98626 жыл бұрын
Sir very nice. This type of vedio at construction site is very helpfull. Thank u.
@Er-NileshGaikwad6 жыл бұрын
Corrections and information :- 1) at a junction, spacing of stirrups should be less and each stirrup should start from the face of the column 2) Tension zone should have more steel than compression zone (Singly reinforced) 3) hooks of the stirrups should be at 45 degree inside the stirrup. 4) plane brick work layer should below plinth beam and should have cover 30 mm at bottom & other sides too. 5)for simply supported beam (seen in video) should be their bars bend as L in Columns . 6) bottom bars should be heavier than top bars in simply and continuous beams and vice versa for Cantilever beams with reference to steel design. 7) stirrups should be perpendicular to the beam bars..And should tie it fix. 8) Extra over support at L/4 should be there at a junction. 9) Always use or refer Steel design and consult a good structural Engineer. 🤗🤗👍👍
@subhasbabu20076 жыл бұрын
There is no rule that it should be more steel in Tenson zone first to check confirm whether it is under reinforced or over reinforced best example sunshade reinforcement is over reinforced element, any structure should be designed as under reinforced only over reinforced designs are very danger. and that subject belongs to Over confidence
@Er-NileshGaikwad6 жыл бұрын
Esikala Venkata subhasbabu @@ read twice what I commented... Same as u studied 👍
@manjusreedas67126 жыл бұрын
10. Always takes expert or professional's Opinion. Otherwise it will be your Big Mistake.
@Er-NileshGaikwad6 жыл бұрын
Manju Sree Das @ good 👍
@laxmigovind73686 жыл бұрын
Did u work in Adani bijpur,Karnataka
@asianengineeringacademy78144 жыл бұрын
Informative Video.Keep it up
@bradleyhouse31806 жыл бұрын
A lot of people here just to bust on your english... I understood every word you said my man.
@dipakphapale1876 жыл бұрын
Its very important information for become a successful civil engineer ...... Thank you
@pawan.iampowerofmodi55806 жыл бұрын
you are best engineer aand completely so love sir........ aand other people is say engineering is not good...... .......... !!!!!who's people's is not good is right
@k2dimack1716 жыл бұрын
Thk you once again I enjoy n learn lots from ur on site videos keep making them plz
@clebsonsantiago6 жыл бұрын
Brazillian here. God job.
@phyohtetkoko9295 жыл бұрын
Noted. Thank you for sharing video 👌
@ART_INDIA6 жыл бұрын
Absolutely right........and good knowledge.....in INDIA it's anything possible.........👍
@kamalakrsna6 жыл бұрын
Bharat mey ... sab chaltaa hey
@divinewinklekwakuepokor29232 жыл бұрын
Perfectly right, most steel guys do such mistakes
@cskhousemodels97914 жыл бұрын
Nicely explained sir
@abdullahikram2965 жыл бұрын
RESPECT & WELL Wishes FROM STATE OF QATAR
@hardhatlife5 жыл бұрын
Very Cool! 💪 👷🏻
@binumathew94256 жыл бұрын
Substandard work.
@MasterCivilEngineering4 жыл бұрын
Right
@gn47206 жыл бұрын
Always refer to structural drawings . Always follow the details on the plans . Any questions call the engineer .
@angrynerd7925 жыл бұрын
Exactly
@MasterCivilEngineering4 жыл бұрын
Right watch more here
@MasterCivilEngineering4 жыл бұрын
Expertise civil engineering knowledge here!
@mohamedabdhakir96334 жыл бұрын
Am from Tamil Nadu i like your video any job inform
@Vishesh_Sharma9995 жыл бұрын
Nyc video sir......
@PADE20006 жыл бұрын
I hope the corrections are made before the concrete is poured. This is a simple correction just measure and mark at the correct intervals. Great inspection comments that could help to avoid major structural failure.
@mario63ist6 жыл бұрын
For those who are confused about why the tension bars are placed at the top of the beam, it is simply because the compression zone is located on the bottom of the beam instead of the top due to the force exerted from the ground on the beam from below. Thats why the upperpart of the beam is being stretched and the bottom part compressed.
@megabuilds30076 жыл бұрын
Okay sir, But can you explain, why upward force from the ground here??
@SuperSetright6 жыл бұрын
@@megabuilds3007 , the weight of the columns at the beam edges will cause the centre of the beam to deflect upwards. (When beam is laying on the ground)
@subhasbabu20076 жыл бұрын
deflection of beam offcourse due to Torison or load coming on....
@issegarawan57166 жыл бұрын
What is compression sir
@stevenbuckley14166 жыл бұрын
What Country is this filmed in ? I’m from the uk
@Jangeersahilofficial6 жыл бұрын
Nice lecture
@kisanmitrahindi6 жыл бұрын
sir I have to setup 500 square feet holding how much depth Kollam in earth required please tell me I am confused
@omargul40836 жыл бұрын
mashalla brother, very nicely explained
@aqeelahmed41606 жыл бұрын
Sir you awesome nice explain
@khondokerazizulhaque3573 жыл бұрын
Nice one
@djstalwartthebossgambia54525 жыл бұрын
You are right sir it should not be more than 6 inches which is 15cm
@khanimtiaz80594 жыл бұрын
good job.very impressive. bro
@eduardomoncao88775 жыл бұрын
Show, parabéns pelo trabalho. BH - MG. Brasil.
@iqbalshaikh5104 жыл бұрын
Always follow steel designer however would u say how much structure depends upon plinth beam
@thecivilsite18443 жыл бұрын
Its so good work
@Guiding1005 жыл бұрын
What about two storey building will it be okay?
@blipco56 жыл бұрын
These mistakes you point out, are they corrected before the pour?
@blipco56 жыл бұрын
Do they fix it? Thank you.
@engcabdiqanifaarax94585 жыл бұрын
I was constructing G+2 and i placed stair cover beam wrong position so could it damage my structure?
@muhammadsaeed61715 жыл бұрын
Nice job
@venkateshbabu56236 жыл бұрын
This kind of instructions should be provided because usually most people are not engineer when it comes to construction and it is difficult to find experts in the field where advice is not provided for construction workers though they are capable of work schedule. And it is a good way to provide some kind of instruction building ideas and support required.
@venkateshbabu56236 жыл бұрын
Whether it is cars or other things people work on only sales and marketing and description of the product and features.
@subhasbabu20076 жыл бұрын
The majority of Labours are Masons and Helpers working in construction field 90% in addition The Vaastu pandits are involving &leading the role of Civil Engineer. Because he creates the fear to the owner and taking in to custody by telling vaastu regarding Bed room toilet North and East . Innocent Owners obey the complete instructions of Masons (Local) and Vaastu pandits.. But No Owner believe the Civil Engineer, who gives the sincere advice
@Tehcarp6 жыл бұрын
He mentioned that he thought it was a problem of nobody marking them out.
@wasimshaukat88475 жыл бұрын
Hi sir, i am confused to see the distribution of main bars. Top bars are less at negative moment junction (near supports) and bottom bars are less at max positive moment zone(middle). Please clear my confusion.
@pathopan66025 жыл бұрын
Good job
@kmrao066 жыл бұрын
I am sorry to say whatever you are saying without referring to approved drawing given by the designer is completrly wrong.
@arafatismael20636 жыл бұрын
designer make mistake. thats why some buildings collapse.
@civilenggtech6 жыл бұрын
Designer not mistake but saving steel 😂😂😂
@MastercraftKARIGAR6 жыл бұрын
He is saying should be done using measuring tape. As per the drawings ofcourse .
@pinedastaglio65006 жыл бұрын
the stress and compression design of the bent bars was inverted according to ICI building code.
@tibs70956 жыл бұрын
He seems to refer to a standard that requires stirrups be placed at most 6 inches apart for that type of building, in which case the actual drawing is not necessary for seeing the mistake.
@kamalbhandari86326 жыл бұрын
In this video show the crank bars up to down is it correct
@MasterCivilEngineering4 жыл бұрын
Know here
@abhishekpatel33565 жыл бұрын
Question: (high rise structures) on my site a beam size is 600mm * 230mm is in a sher wall, the steel in beam is 32 dia and the development length is 42 d. When I placed this beam the top steel ld is more than the length of the length and no space in the sher wall to adjust the ld. in this situation i think the top steel bars ld is keep in the upward vertical direction without compromise the development length. it is right or worng plz explain in detail.
@jarlvisyemoh71385 жыл бұрын
Can I weld reinforcement rebars in beams
@stephenwatson55326 жыл бұрын
I see a cold joint between footing ( with no steel) n stem wall how they gonna form walls later?
@MasterCivilEngineering4 жыл бұрын
Good see here more
@sujit3506 жыл бұрын
Sir wht is lapping?
@obedtari83905 жыл бұрын
Yeah This is also can be as useful information. Please also provide reference document to justify your reasons. In our Case for example Stirrups Spacing should not exceed 300mm (Australian Standard). In that way we will be very confident. Thanks
@sheikhsamy26136 жыл бұрын
Pcc is must to provide before plinth beam
@samadhanghorpade48036 жыл бұрын
No.......not compulsory
@phonecontacts57476 жыл бұрын
@@samadhanghorpade4803 no you are wrong. 2" thick pcc is must.
@subhasbabu20076 жыл бұрын
if not provide PCC is it failure occured for Plinth Beam?
@Buddhi2176 жыл бұрын
PCC is not a must. We provide PCC to level the ground and stop absorbing water in the fresh concrete of structural elements.
@terryjoseph33476 жыл бұрын
You have to make sure that they doing right things at right time to avoid rework instead of last moment inspection.before after during inspection is more better
This is how I feel when I call Amazon customer service
@ekontungoe49556 жыл бұрын
RIP English 🤣
@Butterflylo3286 жыл бұрын
D Garcia lol!!
@pinnturoy71735 жыл бұрын
dbo
@thiyagarajahyogeswaranyoge35174 жыл бұрын
RIB
@MasterCivilEngineering4 жыл бұрын
See here more
@JUNAID_KHAN7086 жыл бұрын
Spacing should be as per IS CODE NA?
@JM-zl8bi5 жыл бұрын
Sir , new constructed house ko pehlibar color kab karna chahiye? Taki popdi na bane wall pe.
@fakruanjal33946 жыл бұрын
Good for ur thinking and all thnk u
@Buddhi2176 жыл бұрын
Maximum distance between shear links depends on the effective depth of the beams. It should be less than 0.75d
@vishwaradhyaaradhya93656 жыл бұрын
In support steel is maximum and at compression zone and in mid span u given more steel on tension zone is it correct?
@RJMDesigns6 жыл бұрын
is that specs based on drawing design or reinforce concrete code, ibc code? from ACI 2? from reinforce concrete ICC..?
@namaste_draftsman6 жыл бұрын
Gd sir ....
@quangtran72294 жыл бұрын
Lean concrete should be casted before setting rebar for plinth beam.
@meghanadhmajeti18526 жыл бұрын
Sir can I know what is the relationship between no:of storeys and Stirrups spacing in beams.?
@paraschauhan83894 жыл бұрын
Bro, there is no relationship between them. It always depends on design of building
@khalidkhursheed82936 жыл бұрын
Spacing depends upon the area of cross section of total reinforcement provided in tension and compression zone, not by visualisation..
@thiyagarajahyogeswaranyoge35174 жыл бұрын
Rebar bindings end should keep inner is the best.
@greggilmour76716 жыл бұрын
Sir, you are making a lot of fuss over what are probably minor issues. I agree with you that the tie-wire should be neatly snipped but it's not the end of the world. As to the fitment spacing, without reference to the drawings everything was said has no context. as long as the maximum spacing is not exceeded it's acceptable.
@sivasankarr68235 жыл бұрын
Sir, thank you so much for sharing of your knowledge with us but I have a doubt regarding spacing between one to another Stirups, problem they definitely but what kind of problem they come if spacing is more between one to another Stirups and what is the lime if the same is constructed.
@MasterCivilEngineering4 жыл бұрын
Watch more here
@abdirizakspeedy66996 жыл бұрын
I think stirrups are alocatad to support shear stress and the ones in the corner must be close to each other because in beam shear stresses are more in corners but the stirrups in the the center can be done in any suitable spacing
@kedici25836 жыл бұрын
You definitely right. In an earthquake beams break up first near to the columns. To prevent it number of stirrups must be increased and placed as close as possible at beam-column connections.
@SIMON-ps6lq5 жыл бұрын
Sir how much beam for 1 storage
@bruceg.62824 жыл бұрын
p.s. When I was working Quality Control, we would have someone spray paint (usually a bright color like orange) a dot at every point where a stirrup should go. Save time and you get it right.
@chandrashekarshekar81525 жыл бұрын
Payment less. Unskilled labour. Work load heavy for supervisor site engineer. Low salary. No value for skilled labour and engineers at the site.
@MasterCivilEngineering4 жыл бұрын
Right dear
@keffiyeh55685 жыл бұрын
Why we cut the bending wire?
@anuragagrawal34985 жыл бұрын
i think in floor beam design it is only depends on load on that floor and some secondary moment which is transferred from column so no 5 story or 8 story matters , every floor beam only transfer load to column and column transfer load to foundation
@fahadnabeel27386 жыл бұрын
Why bentup bars are provided on compression side of all beams????.....plz ans
@ramasamyv76976 жыл бұрын
Same doubt. In this video all beams have more reinforcement have on their compresion zone
@federicobacuzzi25506 жыл бұрын
It is a revers beam foundation The pressure is not downward but upward by the reaction of the ground
@fahadnabeel27386 жыл бұрын
Ty sir
@subhasbabu20076 жыл бұрын
bent up bars used as shear reinforcement as the SF has greater value at the ends of supports and nominal at centre of beam where maxiumum bending moment SF will change hence bent into 45 degrees and extended upto support edge That bent start at 1/4th of span either end
@1.1235 жыл бұрын
a j the load directing to earth center is only punctual at every end of the beam (see the pillars there). but the beam is laying with whole length on the ground. when the load is applied, the ground presses upwards to the beam. it is like a beam with two supportings and a line load - but upside down. that means, that in the middle of the beam the tension side is on the top.
@dannycbe9496 жыл бұрын
Strange. Two observations: 1. What has 5 storey or any number of floors got to do with stirrups in a framed structure beam, that too a plinth beam 2. Why is the crank inverted, with more steel in to layer than bottom layer...is this being designed for upheaval ??. In short a STRANGE vedio !!!
@christianpablo83846 жыл бұрын
I'm actually confused with no. 2 there as well. I can't remember if tie beams are designed against uplift rather than weight imposed above
@tjlibrada84326 жыл бұрын
haaahha.. the designer might actually think that wen equakes comes land shifts are all upward.. designer shud do stand up comedy as well..lol
@quentinstorey19506 жыл бұрын
1 Storey here.
@zt87106 жыл бұрын
That is because this is foundation beam, it is not normal beam like 1st story or 2nd story beam...the columns are pressing down and the soil is pushing up, so near the columns the bottom side of the beam is compresion and top side is in tension, and in the middle of the span the bottom side is in compression and top side is in tension...
@subhasbabu20076 жыл бұрын
improper structural designs material used for concrete are may be inferior quality
@mrsniper2476 жыл бұрын
Spray paint or chalk to mark before prefab
@bruceg.62826 жыл бұрын
I doubt that the beam will fail. I vaguely remember learning in college that a 200 to 300% safety factor is engineered into concrete structures.
@MrPancake7775 жыл бұрын
Probably not. But doesn’t mean it’s okay.
@muhammadyaseen77065 жыл бұрын
Yes, but actually no..... Where I am from, the ACI codes etc are to construction works like Bible is to church.
@MasterCivilEngineering4 жыл бұрын
See here more
@chandangautam2934 жыл бұрын
@@muhammadyaseen7706 He is more than a preacher in church reading his bible.
@danielevb4 жыл бұрын
Agreed. And also, the bin stands on the floor
@AceHardy6 жыл бұрын
👑
@manibm91846 жыл бұрын
Not only stirrups are wrong but more you must protect your concrete against soil and keep a standard concrete section. It needs a carpenter works.
@nayanjyotinath3586 жыл бұрын
When there is any lap splice then spacing between the stirrups shoul be less also which didn't mention in your video
@abdurraquib3876 жыл бұрын
Where is this wrong construction? Country's name?
@rovenytv49516 жыл бұрын
Are you engineer? Do you have a building plan? Even in the 50 stories building have a space more than 20cm between 2 stiraps base on the plan .
@buliding_basics5 жыл бұрын
As per 13920-2016, spacing of stirrups for supported ends should not be more than 100mm, doesn't matter who the designer is. What is your opinion?
@satheeshkumar-wr4ul6 жыл бұрын
Stirrups are just one of your problem. Top reinforcements is lapped near supports which might be a bigger problem
@Officialsunilbhaskar5 жыл бұрын
One of the biggest mistake is, ring stiruff hook is not providing as 135 angle degree...
@arafatismael20636 жыл бұрын
we start measurement of distance of rebars 1 inches 3 times, 2 inches 2 times, 4 inches 4 times then 6 inches until the end of the bar this is the standard we use in Philippines.
@jeremybenedicto37016 жыл бұрын
depends upon the data of beam. not standard here in philippines, that's only "your" standard
@OutdoorAdventuresFun6 жыл бұрын
Different regions requires different standards. What's appropriate in Florida (USA), NYC (USA), California (USA), Philippines, Denmark, Canada, etc. ect. ect. Is completely different. Not one size fits all kinds of standard.
@sangamtamang65246 жыл бұрын
Everything has failed in this video spacing, the hooks, PCC, laps and most importantly English
@ronishpra5 жыл бұрын
hahahahahha
@pratiksarve5 жыл бұрын
Important mistake - The bent-up bars are wrong (upside down)
@philleach62716 жыл бұрын
That stirrups themselves are wrong . The ends should be bent inward at 45 degrees, this whole cage would fall apart in a shake
@MasterCivilEngineering4 жыл бұрын
See here more
@premgdas84476 жыл бұрын
Why the extra reinforcement provided at the middle portion? There it is supposed to have sagging, right?
@subhasbabu20076 жыл бұрын
All extra reinforcements are treated as Shear Reinforcements
@InformativeVideoChannel5 жыл бұрын
First you should check the excavation. You haven't put Lean concrete, and farm work to control the lose material and keep the concrete at required breath
@rupendrasingh88795 жыл бұрын
Good evening sir 24 fit colume space le ght beam ki design bataye sir
@chukhrukidzeee6 жыл бұрын
Hello. I'm watching your videos from Kazakhstan. And it difficult to understand you when you saying inches. Can you make video in mm or cm
@waqarahmed83615 жыл бұрын
Bro 1 Inches = 25.4mm . you can convert it easily, and there are many apps that can help you in conversion.
@jarexmat62286 жыл бұрын
*Looks like the orientation of the girder bent bars are wrong. The supports should more bars at the top, the same as the midspan bottom bars. The rule is put more rebars at areas of the beam that are in tension. *
@aftabhussain43896 жыл бұрын
Good
@extremkais17106 жыл бұрын
sir, i think 45° crank is also wrong. if it is right, please explain...
@subhasbabu20076 жыл бұрын
After observations of the Learned Engineers during Earth Quakes they decided this angle
@rabiugarba84306 жыл бұрын
Engineer saved lives
@mdrakibul94175 жыл бұрын
we know concrete is too much weak of tension. but reinforcement is high tensile... So we should should use reinforcement of tension jone more then compression jon.that's why, w use crank bar. But cranks position absolutely wrong of here..... there cranks position is reverse..... That's why, this beam will fail of tension jone..
@Voice_of_Nature375 жыл бұрын
Yes boss I agree with you. But the video creator didn't tell it. Why?
@haupu50065 жыл бұрын
Is crank bar upside down
@shivkumarverma34635 жыл бұрын
in plinth beam it's ok but shouldn't be in main beam
@muhammadyaseen77065 жыл бұрын
It's foundation, the load is considered the other way around (designed for reaction, NOT action)
@abdurrahim36053 жыл бұрын
Thanks
@stephenbernsen1696 жыл бұрын
I wish I could have understood anything that you said, sounded good tho. Are you speaking english?
@raimohandolin63684 жыл бұрын
Those beam rebars are wrong way round the bottom should be at top! Middle of beams the most bars should be at bottom and on the sides at top . That's the biggest mistake. Near the columns there could be additional bars to lessen the cutting force from other bars on the columns.