मोटर Earth Fault में Trip हो रहा है तो कैसे Troubleshoot करें ? Motor Earth Fault Troubleshooting |

  Рет қаралды 3,869

BOL BULBUL Industrial Electrical

BOL BULBUL Industrial Electrical

Күн бұрын

Пікірлер: 21
@arjunthakur4762
@arjunthakur4762 Жыл бұрын
Bhuthi badhya information step by step sikhaya aapne nice 👌🙏thanks
@BOLBULBULIndustrialElectrical
@BOLBULBULIndustrialElectrical Жыл бұрын
Thank you
@vijaysharma-xh2jy
@vijaysharma-xh2jy Жыл бұрын
Abhi tak ka sabse best channel he jo page pe na samjhkar original equipment me saari jankari dete he aur aapka bataya hua samajh me bhi aata he
@BOLBULBULIndustrialElectrical
@BOLBULBULIndustrialElectrical Жыл бұрын
Thank you Vijay ji
@praveentiwari8490
@praveentiwari8490 Жыл бұрын
Very informative video sir
@BOLBULBULIndustrialElectrical
@BOLBULBULIndustrialElectrical Жыл бұрын
Thank you
@brajeshlalyadav4646
@brajeshlalyadav4646 Жыл бұрын
Very good video
@BOLBULBULIndustrialElectrical
@BOLBULBULIndustrialElectrical Жыл бұрын
Thank you Brajesh
@prosanjitchakraborty2119
@prosanjitchakraborty2119 11 ай бұрын
@BOLBULBULIndustrialElectrical
@BOLBULBULIndustrialElectrical 11 ай бұрын
Thank you
@alamofficial9995
@alamofficial9995 Жыл бұрын
sir place make one video how to check control panel short circuit
@BOLBULBULIndustrialElectrical
@BOLBULBULIndustrialElectrical Жыл бұрын
Thik hai
@vishalthakur7852
@vishalthakur7852 Жыл бұрын
Sir aapse ek cheej janni thi ki jo ACS ki VFD 355 hai vo DCS mai -ve frequency show kar rha hai Esa kyun ho rha smjh nahi aa rha 3 se 4 VFD mai esa ho rha hai ki vo -ve frequency show karta hai DCS mai
@BOLBULBULIndustrialElectrical
@BOLBULBULIndustrialElectrical Жыл бұрын
Feedback wire ka connection change kar do.
@vishalthakur7852
@vishalthakur7852 Жыл бұрын
@@BOLBULBULIndustrialElectrical AO ka wire interchange kar du to ho jaayega na sir Ok ek baar try krunga
@BOLBULBULIndustrialElectrical
@BOLBULBULIndustrialElectrical Жыл бұрын
Agar feedback Frequency -ve dikha raha hai to AI wiring ko change karo. Reference Frequency -ve dikha raha hai to AO wiring ko change karo. Agar phir bhi nahi ho raha to DCS setting check karo. Value 0 - 50 dalo.
@vishalthakur7852
@vishalthakur7852 Жыл бұрын
@@BOLBULBULIndustrialElectrical ok sir
@SunilYadav-ed9xt
@SunilYadav-ed9xt Жыл бұрын
Sir DC shunt compound motor 400 kW ka Power and control wiring per full details me video banayiye
@BOLBULBULIndustrialElectrical
@BOLBULBULIndustrialElectrical Жыл бұрын
Thik hai.
🔴How Ground Fault is Detected?
10:26
A For Automation
Рет қаралды 3,7 М.
So Cute 🥰 who is better?
00:15
dednahype
Рет қаралды 19 МЛН
Chain Game Strong ⛓️
00:21
Anwar Jibawi
Рет қаралды 41 МЛН
Гениальное изобретение из обычного стаканчика!
00:31
Лютая физика | Олимпиадная физика
Рет қаралды 4,8 МЛН
Pull up Pull down Resistor Working in PCB | How to check pull up and pull down resistor in AC PCB
23:59
Multitech Institute Of Advance Technologies
Рет қаралды 43 М.
How to select the ELR rating for a motor/Load?
30:24
Electrical Concept
Рет қаралды 3,7 М.
What is Earth Fault | Electrical Earthing | Electrical Protection |
6:06
Electrical With Abhishek Joshi
Рет қаралды 70 М.
How to troubleshoot motor run feedback problem ? Electrical Troubleshooting Procedure in Hindi |
13:34
IR and WR test क्यू किया जाता हे?
12:14
Gyaan ELECTRICAL
Рет қаралды 55 М.
So Cute 🥰 who is better?
00:15
dednahype
Рет қаралды 19 МЛН