2024 NFPA 70E Major Changes - Jim Phillips, P.E.

  Рет қаралды 7,040

Brainfiller Arc Flash Training

Brainfiller Arc Flash Training

Жыл бұрын

Retraining in safety-related work practices and applicable changes to NFPA 70E shall be performed at intervals not to exceed 3 years. This time frame is so employees can keep up to date with the triennial revision cycle of this important electrical safety standard.
Jim Phillips, P.E. helps you complete this NFPA 70E requirement by walking you through the major changes to the 2024 Edition of NFPA 70E as well as providing a refresher about electrical safety and this important standard.
Some of the changes and additions include:
Relocated Definitions
Deleting the word "leather" from leather protectors
Update Structure for Searchable Format
Adding a Scope to many articles
Global Changes such as adding “Electric” to Shock
Normal Operation 7th condition added - Equipment rated for available fault current
Emergency Response Plan added to Job Safety Planning
120.5 (B)(2) Clarification regarding “Block or relive stored non-electrical energy devices”
120.6 “Test each phase conductor at each point of work” added to ESWC
Harmonize Restricted Approach Boundaries with OSHA’s minimum approach distances
130.5 (B) Clarification that doors do not provide enough protection from an arc flash (unless arc resistant)
130.5(G) Informational Note provides examples of changes that could affect incident energy
130.5(G) New text: labels shall be sufficient durability for environment
Table 130.7(C)(15) (b) DC PPE Category Table significantly revised
320.3(A)(1) New thermal threshold added for battery safety
NEW Informative Annex S - Assessing the Condition of Maintenance

Пікірлер: 18
@j81851
@j81851 3 ай бұрын
Jim, I deeply admire and enjoy your lectures and think you are a stable resource that does not bend to the wind of trends. I recommend you as the "Arc Flash Expert" in all my ESWP classes. You are a lighthouse in the storm of misinformation out there.
@Brainfiller
@Brainfiller 3 ай бұрын
Thank you for your kind words and support! Best Wishes!
@user-yo9ny9lx4e
@user-yo9ny9lx4e 7 ай бұрын
Thank you
@educationpower1823
@educationpower1823 11 ай бұрын
At speed of light
@plchacker
@plchacker 10 ай бұрын
Is there any chance that there will be higher categories of PPE added since we have more capable PPE? I honestly expected this update for 2024.
@Brainfiller
@Brainfiller 10 ай бұрын
Nothing that I have seen is on the radar screen regarding higher catagories for NFPA 70E. Many lean towards calculated incident energy.
@j81851
@j81851 3 ай бұрын
Why? Hierarchy of controls suggests Eliminate the hazard. Have we all not looked at Doughty and Neal in the 90's and IEEE/NFPA collaboration of the early 2000's? 5-12 calorie arc flash 140 db SPL consistently. You guys can wear all the 100 cal stuff you want. My students are trained to reduce or eliminate the hazard. Their leaders need to be trained that convenience and prevention of financial loss still does not justify the risk. LOOK AT THE controls pyramid.. PPE IS THE TIP OF THE SPEAR!! I do NOT care about improvements in PPE, PPE at best is marginal to keep you from being dead. Sound is sound. 141 DB SPL is around 2160 psi pressure to the body. Why are we so adamant to make it electrically safe when in doing so we expose people to huge electrical explosion risk glibly "oh the PPE has improved!!" Really? The Psychics of the arc flash is the same as it was 40 years ago when Ralph Lee published "Arc Flash the the other Electrical Hazard". Yeah I hear you all this is some old guy. Yeah following the rules is why I am still standing at 72. Think about it. Oh, and remember all the whiz bang relaying and fiber loops you do still reduce the hazard but 5-12 calories (rather low values) still generate the maximum OSHA allowable exposure. Again think about it.
@Brainfiller
@Brainfiller 3 ай бұрын
@@j81851 I was part of the steering committee of the final incarnation of the IEEE/NFPA collaboration and on the 70 Committee. There is quite a bit of inertia so veering from the existing categories in the near term is unlikely.
@educationpower1823
@educationpower1823 11 ай бұрын
Jim. I teach that shock is tramua forced on the body..like car accident, baseball bat upside head. etc. Electri shock is electrical trauma forced on body at spoed of light..Robert from Omaha
@Brainfiller
@Brainfiller 11 ай бұрын
Serious shock needs medical attention even if the person seems to be OK. Sometimes effects aren't noticed until sometime later.
@bobcocampo
@bobcocampo 11 ай бұрын
What are the arc flash ratings of metal enclosure covers of panelboards and switchgears
@Brainfiller
@Brainfiller 11 ай бұрын
Metal enclosure covers, panelboards and switch gear do not have arc ratings like PPE. However, some equipment like switchgear can be designed based on standards such as C37. 20.7. This equipment, known as arc resistant, is designed to contain the energy during an arc flash if it is properly closed.
@bobcocampo
@bobcocampo 11 ай бұрын
@@Brainfiller Right now it has no rating. However, if cover will have rating it will assure that the person in front of the switchgear. This may allow person in front of the switchgear just monitoring to be safe without a PPE. If PPE can have a test on Cal per m2 then enclosure covers should have this test too.
@Brainfiller
@Brainfiller 11 ай бұрын
@@bobcocampo Equipment can go thought testing to be arc rated. This is not an arc rating. It is the ability of the equipment to contain the energy. PASS/FAIL not a specific arc rating like PPE. Two different things.
@educationpower1823
@educationpower1823 11 ай бұрын
Also, I have discovered an alarming number of people who do not read the instructions from manufacturer on how to properly use a noncontact test instrument..for example the need to be properly grounded to avoid false readings etc. Thoughts of untrained people relying on this method?
@Brainfiller
@Brainfiller 11 ай бұрын
It's like so many other things. Training is the key and without it, things can go terribly wrong.
@plchacker
@plchacker 10 ай бұрын
130.12? Is there any way to change this word salad? I understand the intent, but it looks like a team of HR/Safety, Lawyers and ISO freaks wrote this. It could simply say, "Before any work is done to electrical equipment/conductors, care must be taken to insure all possible electrical sources have been put into an electrically safe condition." It is suppose to address the possibility of multiple sources or back feeding on a circuit that is being worked on. Every qualified worker would be well aware of this hazard and will take precautionary steps.
@Brainfiller
@Brainfiller 10 ай бұрын
The best way to initiate a change is to submit Public Input (proposal) for the 2027 edition a NFPA.org. The closing date is June 4, 2024. Thanks for your comment.
Arc Flash Studies and Electric Utility Company Short Circuit Data
13:39
Brainfiller Arc Flash Training
Рет қаралды 9 М.
Changes to NFPA 70E 2024 edition
1:05:54
Ryan Jackson
Рет қаралды 6 М.
Вечный ДВИГАТЕЛЬ!⚙️ #shorts
00:27
Гараж 54
Рет қаралды 14 МЛН
Can You Draw A PERFECTLY Dotted Circle?
00:55
Stokes Twins
Рет қаралды 44 МЛН
2024 NFPA 70E Major Changes
1:00:18
ECmagdotcom
Рет қаралды 479
2024 NFPA 70E Simplified: A Condensed Crash Course for Safety Leaders
59:02
Herzig Engineering
Рет қаралды 3,2 М.
2021 NFPA 70E Changes & Updates - Jim Phillips Free Class
1:00:06
Brainfiller Arc Flash Training
Рет қаралды 21 М.
EC&M Tech Talk Video - Changes to the 2024 NFPA 70E
25:50
Coordination, Overcurrent Protective Devices
14:23
MikeHoltNEC
Рет қаралды 8 М.
TRAINING: Arc Flash Safety for Electrical Panels with Gene Reed
19:45
CED Central Industrial Division
Рет қаралды 52 М.
The Most Confusing Part of the Power Grid
22:07
Practical Engineering
Рет қаралды 1,3 МЛН
Arc Flash NFPA 70E
38:25
Willmar Electric
Рет қаралды 13 М.