Thank you for the closeup of the grill installation. Shouldn't be that tough to install, but it was. Your video helped me understand how to finally get it in. Nothing in the instructions indicated how to do it or what it should end up looking like. Thank you again!!
@kenlacey8446 Жыл бұрын
I've been fighting with the springs and cannot get tgem to engage. Even in this video, at 10:16, the springs are arced out and at 10:3 they are arced in. Something doesn't make sense. And for a person with large hands, getting the second one in without the first removing itself has proven impossible for me
@evelynwightman777311 ай бұрын
I got it! The key for me was: first, mark the edges of the clips on the ceiling so I can see where they line up without having to see the clips themselves. Next, on the far side of the fan from me (the side I can see what I'm doing on) flip the springs over and install them so they look like at 10:15. That holds the far side up pretty well. Next, squeeze the spring on the close side and somehow get it hooked onto the hooks like shown at 10:13. It sucks but can be done. Then you can push the whole thing up and it stays like it should. Huzzah!
@conenose110 ай бұрын
Unfortunately I am one of those with big hands and the struggle to put these springs in place is unreasonable to say the least.
@OlivierCaron10 ай бұрын
I spent 15 minutes on this, for a fan 3 times as expensive as the budget one from the same brand I am replacing, the older one was a lot easier to do and felt more secure. Definitely not an improvement for this. I ended up having to bend the spring otherwise it would come out when I pushed it up.
@FloridaRailfanKid803 Жыл бұрын
Great Video
@lessmore90457 ай бұрын
So the housing is fastened on the joist on one side. Will this allow too much vibration?
@benvernon63298 ай бұрын
What do I do if I have no ground wire
@johng29138 ай бұрын
Is it a metal sheathed cable? If it is a metal cable, the cable jacket is the ground (wire). An approved cable connector must be installed on the cable and must be properly tighten to the fan wiring plate. If it is old NM (nonmetallic) cable without a ground wire, the fan should be protected by a GFCI.
@greenworld80 Жыл бұрын
Hi, What is the size of the cable connector?
@johng2913 Жыл бұрын
1/2".
@reynoldsje2 ай бұрын
Why does ours leak?
@dianetrimpey665610 ай бұрын
Doesn't show bathroom or where ventilation is ported to.
@donaldbunnell7003 Жыл бұрын
OK, so I'm nit picking, but he had electrical wires draped over the metal box making contact. Nothing would ever happen, but it is against code to have wires touching any metal.. good video, thank yo for that...
@johng2913 Жыл бұрын
???... I don't know what you see, but believe me everything is fine with NEC 2020 and has been checked by the inspector.