BRX Do-More Simple Modbus Serial Communication

  Рет қаралды 2,066

ACC Automation

ACC Automation

Күн бұрын

Пікірлер: 8
@ACCautomation
@ACCautomation 2 жыл бұрын
More information can be obtained on our website. This includes all of the links mentioned in this video. accautomation.ca/brx-do-more-simple-modbus-serial-communication/ The entire BRX Series PLC can be found at the following location: accautomation.ca/series/brx-do-more-plc/ There are several reasons why we are using the BRX Series Controller. Here are just a few. - Standalone PLC with built-in I/O - Built-in Data Logging - Communication ability - Ethernet Port, RS232, RS485, USB - support for protocols such as Modbus RTU, Modbus TCP, ASCII, K-sequence (DirectLOGIC users), Custom Protocols (ASCII over serial, TCP or UDP over Ethernet) - Built-in Analog input and output - Integrated motion control - High-speed counters - Powerful instruction set (Video of Instructions in software) - Ability to expand the system with a variety of modules - Part of the Do-More series of PLCs which use the same free software. (Do-More Designer) - Integrated simulator in the software capable of external communications for testing The BRX series of programmable logic controllers consist of four different units. They differ depending on the Inputs and Outputs built into the unit and if it has an ethernet port. No I/O Micro PLC unit - (BX ME) 10 Point Micro PLC unit - (BX 10/10E) 18 Point Micro PLC unit - (BX 18/18E) 36 Point Micro PLC unit - (BX 36/36E) These CPUs (Central Processing Units) are also known as MPU (Multi-Processing Units) because of their communication capabilities. Regards, Garry ACC Automation www.accautomation.ca
@AdamLucas-nj9go
@AdamLucas-nj9go 2 жыл бұрын
In this video, you reconfigured the BRX to Modbus master. Are you able to still use a HMI while in this configuration? If not, is there any ladder logic instructions that would allow you to read from and write to the device?
@ACCautomation
@ACCautomation 2 жыл бұрын
Hi Adam, The Modbus serial communication will allow just one master, so you could not put an HMI on the same network unless it is the only master. If the HMI is the master then you would have to communicate to both devices and update the information for each. The C-More EA9 HMI could easily do this communication. I hope this helps you out. Regards, Garry
@KyleOHern
@KyleOHern Жыл бұрын
Hello Gary, I was wondering if you have ever tried to connect a BRX PLC to a LabVIEW DSC Modbus server VIA ethernet or maybe some over Modbus server running on a computer? I am having some trouble where the two are not communicating to each other.
@ACCautomation
@ACCautomation Жыл бұрын
Hi Kyle, I have not used the LabVIEW DSC Mobus server. However, this would mean that the BRX would be the Modbus Client. When sending the Modbus commands from the BRX PLC, are you getting any error messages back? Regards, Garry
@How2Dude
@How2Dude 5 ай бұрын
Hi thanks for the video, When I am following this I get no communication between the controller and the plc. Although if I use the instruction modbus network read or write like your other solo brx video. It works fine. Any ideas? It’s like the scanner is not running
@How2Dude
@How2Dude 5 ай бұрын
I tried this on another PLC and it worked great. Talking with tech support they are replacing the PLC this did not work on.
@ACCautomation
@ACCautomation 5 ай бұрын
Thanks for the update. Garry
BRX Do-More PLC Using Modbus IO Scanner Profile
16:27
ACC Automation
Рет қаралды 895
BRX Do-More PLC AdvancedHMI - Modbus TCP
18:07
ACC Automation
Рет қаралды 7 М.
Какой я клей? | CLEX #shorts
0:59
CLEX
Рет қаралды 1,9 МЛН
Air Sigma Girl #sigma
0:32
Jin and Hattie
Рет қаралды 45 МЛН
Explaining The Basics Of RS-232 Serial Communications
5:59
Unist Inc.
Рет қаралды 459 М.
What is Modbus and How does it Work?
8:58
RealPars
Рет қаралды 1,7 МЛН
Master Click PLC Communication: Ignite your Modbus RS485 passion!
30:00
BRX Do-More PLC Numbering Systems and Addressing
9:27
ACC Automation
Рет қаралды 2,9 М.
BRX Do-More PLC to Stride Modbus TCP Remote IO
23:38
ACC Automation
Рет қаралды 1,2 М.
Understanding Modbus Serial and TCP/IP
12:07
ProSoft Technology
Рет қаралды 1,3 МЛН
Understanding Modbus Serial and TCP IP
12:07
VUI HOC
Рет қаралды 145 М.
Can DeepSeek R1 Actually Write Good Code?
37:28
Garage Tinkering
Рет қаралды 138 М.