I’ve created an Amazon shopping list for everything you’ll need to build this dim bulb current limiter. You can order the parts from my Amazon affiliate page: www.amazon.com/shop/fluxcondenservintageaudioelectronics?tag=onamzfluxcond-20&linkCode=ic7
@teekay_13 жыл бұрын
The parts list is missing. Perhaps something changed?
@fredashay2 жыл бұрын
Can you give me some advice? I've been looking for a true power isolation device for years -- not just a transformer and surge combination. Something more like a 120VAC motor connected to a 120VAC alternator with an insulated axle so the output voltage is truly isolated electrically from the mains. Does something like this even exist? I haven't been able to find anything like it despite countless searches.
@SDsailor711 ай бұрын
Why is it necessary to remove the break off tab from the switch? and what if the switch does not have a break off tab on it? then what do i do? Thank you, very interesting video and also informative👍
@montygibbon19058 ай бұрын
@FluxCondenser Would you consider building & uplosding a bucking transformer? (For the purpose of knocking down AU & UK voltages from 250v to a China friendly 220v and/or from 120v to 110v.)
@richferraro44222 жыл бұрын
IMHO this is the best (and slickest) current limiter I’ve seen. So nice and compact. My voltage meter doesn’t kick in until 34V is reached which is probably normal and not a problem. Thank You for posting this professionally done video!
@1pilotsteve Жыл бұрын
I just built mine.... exactly how you said... Ultra Mint and works great... Thanks for all your videos.. I wish I had a teacher like you in School.
@weschilton2 жыл бұрын
I just built this current limiter yesterday. I can't thank you enough for this really well-presented video. My switched outlet was completely different than the way your was set up (yay standards!) but it was pretty easy to confirm the connections with my multimeter and, with the final testing to confirm the circuit, the build came together in a leisurely hour... including testing it with my variac. My friend handed me a valuable vintage amp to repair, and now I feel confident turning it on without blowing it up!
@FluxCondenser2 жыл бұрын
Glad to hear! Well done.
@junolanding558 Жыл бұрын
Good set up. The best of the 4 I've seen so far. Thanks
@donaldpingitore90002 жыл бұрын
Completed mine today. Happy that I have added it to my bench.
@IrwinCespedes3 жыл бұрын
My father used to make these as tools in a more empyrical way when he owned a sound system for parties and small concerts. He used to use this tool to check when amplifiers didn't work. Nice memories! Excellent video, you should let viewers send you pics of it already done!
@FluxCondenser3 жыл бұрын
Thanks Irwin, and thanks for sharing those memories. Great idea! If anyone wants to send a pic of their build let me know and I’ll be sure to publish it.
@kevinanderson76132 жыл бұрын
I love this design. I viewed quite a few videos and online guides and this was the best I found. I built one based on your plans, it looks great! I appreciate the quality of your videos!
@FluxCondenser2 жыл бұрын
Glad to hear!
@randallbarnett40483 жыл бұрын
I made a dim bulb current limiter by buying and following your instructions. Thank you for this informative video.
@FluxCondenser3 жыл бұрын
Fantastic, Randall! Gald to hear that. My pleasure.
@btinsen Жыл бұрын
Nice clean simple but effective design. I ordered everything through your link. Works great! Thanks!
@Johns-lp9en3 жыл бұрын
Thank you do much for providing this video! I built it, used it, and it worked perfectly.
@FluxCondenser3 жыл бұрын
Fantastic! Well done.
@PrimeHiFi3 жыл бұрын
Fantastic video. I will follow this for when I make my own. It’s one of the last tools my bench is missing
@FluxCondenser3 жыл бұрын
Thanks, Connor. Good luck with the build. It’s a fun, simple and rewarding little project.
@PrimeHiFi3 жыл бұрын
@@FluxCondenser just finished the dim bulb tester today and it worked like a charm! I’ll be sure to purchase the volt meter through your Amazon store tomorrow. Thanks for the hours of entertainment and helpful videos. It really helps beginners like me out! Much appreciated :)
@FluxCondenser3 жыл бұрын
@@PrimeHiFi Thanks for the support and kind words, Connor. Glad the dim bulb tester came out well. Take care!
@triplefoam Жыл бұрын
A great video, if not one of the best for a DIY dim bulb tester. In the 70's my dad and I used a hanging switched mechanics shop light reconfigured with a plug for the device in his TV and Stereo repair shop.
@sjlBoise543 жыл бұрын
Best dim bulb video - only requires one outlet/fixture box. The plug-in bulb socket is brilliant and simple (most use a separate junction box and a surface fixture), as is the voltmeter.
@FluxCondenser3 жыл бұрын
Thanks, Stephen.
@MartinFahsel6 ай бұрын
@@FluxCondenser I completely agree! I just bought the parts to build and, since I have ample three-prong power cords, came in below your cost. Thank you and I have subscribed to your feed.
@crimsonghost64543 жыл бұрын
Thank you again for another great video. This is an important subject and tool. The way you demonstrated it and explained it was perfect. Love your videos.
@FluxCondenser3 жыл бұрын
Thanks, Crimson!
@niaceri12 жыл бұрын
Thank you so much for doing this. The instructions were extremely clear, and the parts list (and numbers) very helpful. I completed my build this morning. All works well!! Now if I could just find a way to stop my KT88 SE amplifier's Power Transformer from buzzing! 🙂
@Movieman19656 ай бұрын
I saw on another video post that the transformer laminated plates could be loose. Look for the video on YT.
@andydelle45093 жыл бұрын
I built mine a bit differently. I used a split duplex outlet (break the tab on the brass screws) and a double pole switch (HD & Lowes have these too). The lightbulb (or 6amp Edison base fuse) plugs into one outlet side, the device under test into the other, both interchangeable, wired in series. The double pole switch ensures both sides of the AC line are disconnected when off. I know the neutral is grounded at the service but just a little extra safety. I also put in a 1/2in neon "power on" indicator. Since those "plugin" bulb sockets are cheap, I have a few with 40, 100, 200 watt bulbs already installed. I do like your plastic box. The less grounded metal on the bench, the better.
@FluxCondenser3 жыл бұрын
Thanks for sharing your build, Andy. There are a lot of ways to go about it depending on what the user is looking for.
@JoeJ-82823 жыл бұрын
If you build one that way using only one duplex outlet, then you also have to break the tab on the other side of the outlet also and then use a jumper wire from the neutral terminal of the first outlet to the hot terminal of the second outlet before finally going back to neutral from the second outlet, otherwise you end up with reversed polarity on the second outlet, which is of course a dangerous shock hazard when testing certain equipment that has the neutral connected to the chassis, because with reversed polarity on the DUT outlet then you end up with hot being sent to the chassis of some older equipment!
@andydelle45093 жыл бұрын
@@JoeJ-8282 True, but you shouldn't be working in hot chassis equipment without an isolation transformer. I do have one and put it in front of the dim bulb tester if working on hot chassis gear. That would include modern switching power supplies. And safety issues aside, even with the chassis on the neutral you still have a problem with the neutral wire impedance back to the main panel where it ties to the service ground. This is more than enough to cause significant measurement errors with grounded test gear..
@JoeJ-82823 жыл бұрын
@@andydelle4509 I don't think you understand what I mean when I refer to "hot" going to the chassis of the equipment. There is NO piece of manufacturer built equipment that deliberately wires the hot lead to the chassis, (that would be just plain stupid and a major safety and even fire hazard!), but when I said you may eventually get shocked by having the hot on the chassis, due to the NEUTRAL lead of the power cord of some older equipment being connected to the chassis in certain circuit designs, and then your outlet box of your dim bulb tester, (with the way you have it wired), sending hot onto the neutral lead of the equipment being tested, because it backfeeds THROUGH the bulb itself on the bulb's neutral side, and then, (unless you have BOTH metal connecting tabs on your duplex test outlet broken off AND you wire it as I mentioned earlier, above), then you have the neutral side of the bulb outlet, (which essentially has the hot lead of incoming power on it because it feeds through the bulb first), you have that then going directly to the neutral side of the equipment to be tested outlet, which is not good, because then the hot can get back onto the chassis of the equipment under test on the neutral side of the equipment's power cord! That is why it is essential for best safety to wire the test box duplex outlet as I said in my first comment to prevent the polarity reversal on the second, (DUT), outlet... Now an isolation transformer will help with the danger of that and you getting majorly shocked as a result of having the test outlet wired backwards, but it won't be as safe as it could and would be if your test outlet was wired properly in the first place. In order for any electrical power sources to be totally connected in series, you must wire hot to first device, (bulb), then neutral of that to the HOT of the 2nd device, (DUT outlet), and then the neutral of the 2nd device/outlet back to the power source neutral, but that is ONLY possible, (i.e. with the correct polarity on BOTH outlets), IF BOTH metal connecting tabs on both sides of the duplex outlet of your test box are broken off/separated, and then you wire the neutral screw of the 1st outlet to the hot screw of the 2nd outlet with a jumper wire instead... Think of it kind of like a flashlight with 2 batteries in it. In order for a proper series connection to happen you must have the 2 batteries connected + to - in the middle, otherwise the circuit won't work. (Maybe that's not the best analogy, but hopefully you can see the resemblance, even though the voltages are totally different, along with it being DC in batteries, and AC with this tester we're talking about), but even AC has a polarity to it in relation to ground, as you prob. already know, and the hot side can be quite dangerous to touch in most cases. In the case of you always using an isolation transformer, that alone has saved you from getting majorly shocked with your test device as it is wired, but you wouldn't even NEED an isolation transformer in the first place to be safe if your test outlet box was wired as I suggested in the first comment. Anyway, I hope you can understand WHY I'm suggesting that you should change the wiring around on your tester's second outlet, because the way you have it now is ultimately not totally safe to use, and if you or anyone else was to ever use it as it is without the isolation transformer then you could potentially get injured, but if you fix the wiring to be like I described in my first comment then it wouldn't really matter if you used an isolation transformer or not, because it would then be safe either way, at least provided that the device you're testing also has a polarized plug, which most do. Of course you still CAN use an isolation transformer in either case, for the ultimate in safety and isolation, but if the wiring in your test box was properly fixed then it wouldn't be absolutely necessary for prevention of shocks, it would just then be more for the equipment's sake. I'm not trying to diss on your overall design at all, I'm only trying to help you make it a safer design for your sake!
@andydelle45093 жыл бұрын
@@JoeJ-8282 I am an EE of 40 years. I fully understand what you are proposing and may even do it. It's a simple fix. My career has also involved work on broadcast transmitters and large UPS systems. I am fully versed on deadly voltages and current. But no audio gear above an old table radio uses a hot chassis any more. "Hot chassis" is an industry term for tying one side of AC line to the chassis or signal ground. It does not necessarily mean to tie the hot side to the chassis. Some pre-1980s TVs still used hot chassis as they needed a cheap source of over 100 volts anyway for some of the circuits. But in any transformer or switch mode power supply fed device, the chassis ground is isolated from BOTH sides of the AC line. But once inside any gear, you should use an isolation transformer. Especially today in that many switch mode power supplies are build on the same PC board as the rest of the electronics to keep costs down. You have many exposed internal components that may be direct to the AC line, both sides. You also can't assume the wall outlet is wired properly. It's quite common to find them reversed as well. Most videos here show dim bulb testers with open terminal pony sockets mounted on plywood. Talk about safety hazards!
@ETG1682 жыл бұрын
Important: Do NOT solder wires that are going to be clamped down in some manner. The solder will cold-form over time, causing a bad connection and possibly a fire hazard. Instead, twist the wire together well, and if using a screw terminal like on an outlet, bend it in the same direction as the screw will turn when fastening, usually clockwise. This way, instead of pushing the wire out when you tighten the screw, it will instead be clamped down. Even better, if available, you can use a crimpable fork terminal for an even more secure connection.
@FluxCondenser2 жыл бұрын
Huh? No soldering was shown or advised in this video.
@LelleKidd2 жыл бұрын
@@FluxCondenser 4:00
@TheCheesyRice Жыл бұрын
@@FluxCondenser I think he means where you tinned the leads
@greebo785722 күн бұрын
Had a house fire from exactly that. "Hard" joints heat up, harden more, heat up... rinse and repeat.
@SD-nj1cyАй бұрын
@FluxCondenser - I built one and it worked perfectly. I no longer need it to work as a limiter. How do i change the wiring so i can use it a switched 3 outlet extension cord ? Thanks in advance
@kirkdegler65162 жыл бұрын
Thanks for sharing this. Definitely among the cleaner and safer designs I've seen. Built one following along to your video.
@jamescowan79402 жыл бұрын
I don't see the switched outlet you list on the Amazon parts list as the same in the video. There isn't a gold connection to make the jumper.
@kirchgoens2 күн бұрын
I’m having the same problem. The switched outlet he linked in the parts list is not the one he used. The list switch has no black screws and fewer total screws.
@richardadelberg89613 жыл бұрын
I’m still stuck with parts ordered from your Amazon kit because the switch and outlet don’t have three screws on either side!! So get to 3 rd to I don’t know where to run wire?
@willardthompson6648 Жыл бұрын
Love this design! Built one but had to buy a 1/2" box and 3/8" strain relief. Fit tight enough I didn't have to glue. Press fit. Good luck finding the 150 watt incandescent bulb.
@eddomanowski4566 Жыл бұрын
Thank you very much for the instructions on the dim it's been very helpful although I do have a question about the digital voltmeter mine doesn't seem to match with the multimeter it's coming up 116 in the multimeter says $120 is that a common thing with these dm55
@beanmeup99027 ай бұрын
Brilliant! Bravo Sir!
@JoeJ-82823 жыл бұрын
In case you didn't know about it, there is a special glue-in adapter available at Lowes or Home Depot, (or most other electrical supply stores), that you can use with that PVC box that has a rubber insert in the end that has a hole in it that's the same diameter as the round power cord, along with a threaded ring that tightens down onto it so the cord doesn't pull out. It is specifically designed for cords of this round type, and it is an even neater, more professional looking way to do the cord strain relief, and it works just as well as (or even better than), the black push in cable clamp that was used here in this video, except that with the glue-in one you don't have to modify the box hole at all first, you just glue it in with some conduit or PVC glue. The black cable clamp that was used in this video is made specifically for Romex wires going into a metal enclosure such as a breaker panel box.
@rul1175 Жыл бұрын
What is it called???
@olegg933918 күн бұрын
I have a question, why do you break off the metal switched outlet tab? It will just change on/off swither polarity. I think you could connect hot wire to the white screw at the top right avoiding the jumper cable from top left to the bottom right by using the metal tab connector.
@jimmyjohn74907 ай бұрын
I can't find a switch outlet as you've described in your video. I ordered from your Amazon shop and the outlet I received has two brass screws on one side and a green ground and then it has a brass and silver screw on the other side. None of the screws are next to the switch and there are no black screws
@kirchgoens2 күн бұрын
Same problem here.
@kirchgoensКүн бұрын
I found the same part @fluxcondenser uses. It was at Lowe’s. Eaton part number TR274V-BX-LW “Combination Single Pole Switch and Grounding Receptacle.” It has the same black screws, etc. About $11.
@MicSokol Жыл бұрын
Great project, I was thinking to do the same. I wish you have shown a short circuit.
@uptownphotography2 жыл бұрын
Well done and very well explained...I am in the market for a Variac, (for guitar amplifiers), so I will watch that video next. Thanks. Phil NYC area
@edgancarcik88562 жыл бұрын
Thanks for the great video. I was able to sneak in a filtered IEC power connector on bottom portion of case. Makes for easier storage and I also find that the common mode filtered front end helps keeps AC power noise levels from swamping front AM bands. Dimmer switches are horrible noise sources !!!!!!!!
@jefflapoint21953 жыл бұрын
Great design and video. I made one, works great! I changed the bulb to a miniature 100w spot light to save some space. I love the volt meter addition, I would not have thought about it and its cheap.
@JasonHunley2 жыл бұрын
Thank you for this! I tried making one today. It passed all the tests EXCEPT for the one where there should only be continuity when the switch is in the on position (hot prong of power cord and hot side of dual outlet). I can’t identify where I went wrong. Any ideas?
@FluxCondenser2 жыл бұрын
I’m not certain where things went wrong, but the issue, evidently, is that the switch isn’t acting as a switch (enabling and disabling current. So use this to help your diagnosis. Perhaps do a simple schematic illustrating how the circuit should function and compare that to your wiring. Good luck.
@FluxCondenser2 жыл бұрын
And also, you may want to temporarily disconnect your wiring to do simple continuity tests on your switches and outlets. Put your multimeter in “beep” continuity mode and confirm which terminals open and close continuity (no beep/beep) when you activate the switch.
@JasonHunley2 жыл бұрын
@@FluxCondenser Thank you! I went back and discovered there was a tiny sliver of metal left over from the break-away tab.
@levi2bear3 жыл бұрын
Mr. Condenser you videos are very informative and excellently presented. I wonder if you could be so kind as to recommend an isolation transformer or perhaps the appropriate specifications for one. I will say aging you have the gift of making the complex understandable, Many thanks.
@FluxCondenser3 жыл бұрын
Thanks! The Tripp Lite isolation transformers seem quite good. There are three models available which are similar but have the following different wattage ratings: 250W, 500W, 1000. The higher wattage units are naturally more expensive. For most radios and basic stereo equipment, the 250 watt unit may be fine. If you’re dealing with larger amps, etc., you’ll need to go higher depending on your needs. Figure out the wattage of the most demanding device you’ll have on your bench and go from there. A little extra cushion wouldn’t hurt. Remember that these units don’t isolate the ground, so if you need that, use a simple cheater plug. Tripp Lite isolation transformers are available on Amazon, and you can find more info here: www.tripplite.com/products/isolation-transformers-standard~25-112
@levi2bear3 жыл бұрын
Thank you so much for the prompt and courteous reply. I feel I have learned so much from you good teaching.
@richardadelberg89613 жыл бұрын
Not sure about wiring? I ordered directly from Amazon from your parts list . However my switched outlet doesn’t have black screws or three screws to put white wire to jump from switch to outlet ?
@FluxCondenser3 жыл бұрын
Richard, sorry to hear that. Fundamentally, though, if it’s similar switch it can be wired in the same way I show. It’s just going to be a matter of locating which terminals on your switch are intended for the hot connection, and switch connections. Once that’s established, you should be able to use my guide to make the proper connections. If you’re at all unsure, though, you might want to try to locate a switch that more closely matches the one I show in the video. Good luck.
@richardadelberg89613 жыл бұрын
@@FluxCondenser well it didn’t work so I guess the power coming in to side of double outlet was wrong side of socket. I got zippo out of anything no matter where switch was. Went to home depot and all they had was outlets with 2 screws on each side as well.
@FluxCondenser3 жыл бұрын
@@richardadelberg8961 OK, just use a multimeter to check for continuity while activating the switch. That should help you figure things out.
@richardadelberg89613 жыл бұрын
@@FluxCondenser shouldn’t I run hot wire to switch first then instead of double outlet and then from switch outlet to double outlets?
@daperl22 жыл бұрын
Well, I didn't break off the switched outlet tab and I connected the cable hot to the non-bridged switch screw. I passed all your tests and I passed all my tests (actually shorted one of the dual outlet sockets and the light went on) so I'm not sure why you cut the tab and made the pigtail. Still like to know.
@kirchgoens2 күн бұрын
Others on KZbin also don’t break that bridge. I’m confused.
@groovy1937 Жыл бұрын
I like this dim bulb tester or limiter!!!
@jocool7370 Жыл бұрын
Thanks for the video! I've just replicated this build to great success.
@SwanseaTitanFan3 жыл бұрын
Thanks for this. Groovy music.
@FluxCondenser3 жыл бұрын
My pleasure, Marty.
@sushimaster1003 жыл бұрын
Very nice, well explained, and to the point. Not too difficult to follow. Subscribed.
@FluxCondenser3 жыл бұрын
That’s about the best testimonial I could ever hope for. Thanks so much, Armstrong. And welcome!
@billreith43432 жыл бұрын
If using with isolation power supply would it be best to use polarized cord without ground. Otherwise are we not defeating the isolation?
@FluxCondenser2 жыл бұрын
To be fully isolated, yes a cheater plug can be used to eliminate the ground.
@netlogic1ify3 жыл бұрын
Saw the link to Amazon but the cable connectors there is 3/4" and the hole of the electrical box is 1". Any suggestions? Thanks!
@FluxCondenser3 жыл бұрын
Check to see that the model number on your box is E9802E. That box is designed to be used with what’s called a ¾” connector, but the actual hole in the box is much larger. If your box has a ¾” marking on it, it will work with the ProConnex 44741 NM/SE Plastic Cable Connectors which are 3/4-Inch.
@netlogic1ify3 жыл бұрын
That's what I bought from Amazon and it's the same number with 1" hole. Anyway thank you for video construction and advice.
@jordanrussell345 Жыл бұрын
What wire stripper are you using?
@CurtTomhave Жыл бұрын
When I plug my Sperry Stop Shock tester on the bulb plug it reads open neutral, is this expected? Also, I purchased a bulb plug the has the large and small pigtails indicating polarity, is this important?
@heyyaheyya28103 жыл бұрын
I want to build this but the voltmeter takes 2 weeks to deliver. Can I build it the same way and just add the voltmeter when it comes and use it meanwhile? The other parts are available now.
@FluxCondenser3 жыл бұрын
Absolutely! The voltmeter is completely optional. Useful, but optional. Just make sure you’ve got some means of double-checking the voltage coming out of your Variac/Isolation transformer. I’ve got all the parts to build this listed on my Amazon Affiliate page if you want to start there. Anything you purchase there helps out the channel. Check it out, if interested: www.amazon.com/shop/fluxcondenservintageaudioelectronics
@heyyaheyya28103 жыл бұрын
@@FluxCondenser TY. After reading your reply and giving some thought, apparently the the digital voltmeter outlet can be used as a standard outlet (with the same voltage as applied by the variac to the other outlet). And, AAMOF, the voltmeter could be removed after finding the actual voltage being applied by the circuit and even another receiver being tested could be plugged in? (Not sure why I would want to, but just trying to understand how the circuit is working).
@FluxCondenser3 жыл бұрын
Yes, that’s correct. Both outlets on the dim bulb tester are the same and either one or two can be used. I can’t think of a use where I’d want two components plugged into it at a time, either, but if they were within the limits of the bulb and Variac, yes, that would be possible. I wouldn’t recommend it though, as if there were a short in one component it will put full current into the other. The real intention of the extra outlet is just to make it simple to add an inexpensive, yet reasonably accurate voltmeter.
@flossflink3 жыл бұрын
nice, clean build!
@FluxCondenser3 жыл бұрын
Thanks, Ritchie.
@jjg27533 жыл бұрын
how to do if it is UK plug?
@FluxCondenser3 жыл бұрын
If the winner is from outside the US, I will rewire it. The kit has options for different voltages and the UK will not be an issue.
@jjg27533 жыл бұрын
@@FluxCondenser Understood. Thank you very much.
@1marcelfilms2 жыл бұрын
Bulbs are nice for old radios. especially with everyone getting solar the outlet voltage is almost 240v.
@cdavidhord3 жыл бұрын
I love this channel!
@FluxCondenser3 жыл бұрын
And this channel loves you, man! Thanks again for your continued support, Dave.
@rul1175 Жыл бұрын
What would happen if you unplugged the light bulb socket??? will the circuit be open??? Ex. Left(switch on and nothing connected to the outlet) Right(the radio connected in either outlet.)
@FluxCondenser Жыл бұрын
Yes, if the bulb was removed or the filament blows, the circuit would become open and power would be removed from the device under test.
@nelsondog1002 жыл бұрын
I can’t find incandescent bulbs. Is there an alternative?
@ThePolaroid669 Жыл бұрын
very awesome video! What model radio is that that you used? It's amazing!
@richardcote96633 жыл бұрын
Fun video. Thumbs up. I don't understand why the lower wattage bulb reduces the current more? I was expecting it to be the other way around. I expected the 150 watt bulb to draw more current and cause you to increase the variac. I'm confused. Please explain.
@FluxCondenser3 жыл бұрын
That’s a good question, Richard. In this setup, the bulb serves two roles: 1. Provide a low-resistance pathway of current for a device plugged into the current limiter that is operating normally. 2. Provide a safe place for current to go when a device plugged into the current limiter is drawing too much current due to a short, etc. Under the first scenario (when a non-shorted device is plugged into the current limiter) the bulb never receives enough current for the bulb to draw its maximum wattage (it glows dimly). This is because the circuit to the lightbulb has the resistance of the device plugged into the current limiter reducing the current to the light bulb. It’s like wiring a light bulb normally, but introducing a resistor to the circuit. In the second scenario (when a shorted device is plugged into the current limiter, which is basically what the current limiter is designed to provide protection for), the bulb does receive enough current for it to draw its maximum wattage (it glows brighter). That’s because a shorted device plugged into the current limiter is basically the same as wiring a bulb normally with no resistance. I still haven’t explained why the lower wattage bulb reduces more current in normal operation. That’s simply because a lower wattage bulb has a thinner filament than a higher wattage bulb. The thinner the filament, the more the resistance. The thicker the filament, the less the resistance. So using a lower wattage bulb is like adding a bigger (more resistance) resistor to the circuit. Hope this helps.
@richardcote96633 жыл бұрын
@@FluxCondenser Great! Got it now. Wasn't thinking of it in terms of a resistor. Makes perfect sense. Thanks. Keep the vids coming.
@sjlBoise543 жыл бұрын
So - are the more recent "variac" transformers that look like this one and available on Amazon isolated or not? e.g., Mophorn TDGC2-2KM. Or would you need to buy and disassemble it again?
@FluxCondenser3 жыл бұрын
If it doesn’t state that it’s an isolated unit, it’s not going to be isolated. Most Variacs are not. If you do find one that claims to be isolated, though, it’s a good idea to double check. You won’t really need to disassemble it. A simple continuity check will do the trick. Isolated Variacs are hard to come by and I believe the one I own has been discontinued.
@zoltankecse991 Жыл бұрын
Hi! Great video. Please tell me. Can I use the lamp in series after the isolation transformer (230/230) at the same time in the same circuit? Like this: Main power (230) -> isolation transformer -> series lamp -> and socket (outlet) Is this right? ( I want to test audio amplifiers.)
@wclifton968gameplaystutorials2 жыл бұрын
Here in the UK you can buy 3, 6 and 8 gang sockets and the rear housing for them meaning that you only need to use one set of wires, so one from the plug and connect it to the rear terminals of the socket which means that you don't need such complex wiring arrangements...
@FluxCondenser2 жыл бұрын
?
@wclifton968gameplaystutorials2 жыл бұрын
@@FluxCondenser??? "gang sockets" means "recepticles" or "the holes the plugs go into" and the "gang" means more than one socket in the same housing since many sockets only come with 1 set of holes in Europe, UK, most switched of course since things are safer over here...???
@FluxCondenser2 жыл бұрын
My question is not what the simplistic terms “gang” and “receptacle” mean. But rather, how your comment pertains to this project. If you’re just pointing out some differences in availability of products and codes in the US vs UK, that’s fine. However, some readers might infer from your comment that using such products would negate the need for “such complex wiring” in this project.
@estotts2 жыл бұрын
Is this the same as a dim bulb tester if you dont use the variac?
@FluxCondenser2 жыл бұрын
Yes.
@jdoe4548Ай бұрын
this is some magic
@daperl22 жыл бұрын
Really enjoyed your video and the rest of my parts should be arriving today, but I have a question(s): Why do you need to cut the tab on the switched outlet and add a pigtail? Isn't it the same result if you leave the tab in place and just wire the wall cable's hot lead to the switches top screw? Thanks.
@peternotpeter2 жыл бұрын
I've just built this dim bulb current limiter, just one question, how would you add an ammeter to this? it would be more useful to know how many amps is going out to the DUT
@FluxCondenser2 жыл бұрын
Yes, that would be a useful addition. Simply plug the ammeter between the dim bulb and DUT.
@peternotpeter2 жыл бұрын
@@FluxCondenser I was thinking of a way to add banana plugs on the hot line to measure with probes but then it would leave the line open if the probes are not used or just add an ammeter gauge somehow
@FluxCondenser2 жыл бұрын
I’d consider getting one of those plug-in amp/watt meters. They’re handy to have around the house and good for work on vintage electronics. You can use it with the dim bulb and without.
@daperl22 жыл бұрын
I did my short test without the volt meter since it doesn't arrive till today. Will a short fry the volt meter?
@FluxCondenser2 жыл бұрын
The short test just sees if there’s continuity. By continuity, we mean there’s a closed circuit and electricity can flow through the path under test. Of course nothing should be plugged into the wall. The continuity is tested using the battery in your meter. It simply sends a small voltage out of one probe and checks to see if the voltage is returned at the other probe. If so, there’s continuity and the meter will beep.
@bigfoottoo284115 күн бұрын
NO AMP METER? I spent my career repairing electronics and never once used a dim bulb. I always used a variac and current meter. The first thing is to have a good idea as to how much current the device being powered normally draws. As you turn up the variac, keep a close eye on the current draw. If the current draw is to high, back down the voltage. I always monitored the current and voltage. The current draw could be just a small amount beyond expected which is good information to know before you start troubleshooting. This process worked very well for me.
@jerrybonifacio95742 жыл бұрын
hi - I have Variac Transformer TDGC2M 2000VA, can I used a 2 prong adaptor to isolate the Grounding ?
@FluxCondenser2 жыл бұрын
That will isolate the ground, but your hot and common won’t be isolated that way with a typical variac. It takes more than an adaptor to isolate a Variac.
@philliphanford27922 жыл бұрын
How long do you leave it on to condition capacitors in a guitar amp if: 1.) It is brand new (built it yourself) 2.) The amp has been sitting around for an unknown time.
@FluxCondenser2 жыл бұрын
I don’t recommend conditioning capacitors and a dim bulb current limiter is not the device you would use for that anyway.
@Chris-bg8mk6 ай бұрын
You can use the same cable grip shown here with a small amount of PVC cement to just glue it into the box, no dremel or grinding required. :)
@kunaca3 жыл бұрын
Do you have the link to the variac? Cant find it in your amazon link.
@FluxCondenser3 жыл бұрын
That Variac no longer seems to be available. A company called PHC enterprise once had that isolated Variac on the market and available through Amazon, but their web site and variac seem to be gone. If you want a new setup, I’d recommend getting a typical Variac (non isolated) and also purchasing a Tripp Lite isolation transformer to use with it. You could also take your chance with a used Sencore Powerite variac/isolation transformer on ebay. Those are good units, but you’ll want to verify the safe operating condition of anything you buy from ebay. Good luck!
@ciweld3 жыл бұрын
My question is. If there was a short in the radio, then the bulb would have quickly burned out before damaging the radio?
@FluxCondenser3 жыл бұрын
No, a short won’t blow the bulb, it’ll simply make the bulb glow to it’s maximum wattage. A light switch is nothing more than a short in the wiring. So, a short in the radio is nothing more than a light switch. That said, while a short in the radio won’t blow the bulb in a dim-bulb current limiter, the bulb will absorb a great deal of current which can potentially greatly protect the radio or other device from severe damage. A fuse, on the other hand, IS designed to blow in the event of a short, provided enough current runs through it that goes over its rated amperage.
@mworke3 жыл бұрын
Great video
@FluxCondenser3 жыл бұрын
Thanks!
@kilgoretrout44612 жыл бұрын
I’m stumped. Built nearly identical limiter, when testing continuity, everything tested perfect. But the thing is dead. I don’t get it. Is there a situation where it would test 100% correctly but be completely non-functional? The outlet is hot, the volt meter works when plugged directly to the wall…but I get absolutely nothing when I plug the limiter into the wall. Any ideas about what the hell I’m doing wrong here? Thanks.
@FluxCondenser2 жыл бұрын
If the outlet is hot, then the limiter can provide voltage to the device under test. If you mean by saying, “the thing is dead” that the bulb doesn’t light, remember, whether the bulb illuminates is dependent on how much current is passing through it. In a circumstance where you’re using a high wattage bulb and there’s little resistance at the outlet, you won’t necessarily see the bulb illuminate. And, if there’s no load at the outlet (nothing plugged in or switched on) the bulb would not illuminate at all as there’s nothing to close the circuit.
@kilgoretrout44612 жыл бұрын
@@FluxCondenser thanks for getting back to me. I meant that the volt meter isn’t working when plugged into limiter. It works fine when plugged straight into the wall, but I get nothing when plugged into limiter. I guess I must have wired something incorrectly, but it’s a little surprising to me that every continuity test worked perfectly…yet no outlet on the limiter is getting any juice. That make more sense? Thanks
@CraneofBoulogne2 жыл бұрын
A schematic showing how you wired this up would be helpful. Lowes and Home Depot are thirty odd miles away for me, it is far better to order parts via mail order of one form or another. My part won't be the same as yours and therefore may not have the same terminals in the same places, as you noted in this video.
@FluxCondenser2 жыл бұрын
It’s not a traditional schematic, but I do show a diagram of current flow which amounts to the same thing. Further, if one can’t understand the wiring of such a simple device, I’d have to wonder at not only their need for current limiter, but also their ability to be working with high voltages at all. Truly, if someone has a problem building this thing from the instructions I provide, they have no business building this thing in the first place.
@kirchgoens2 күн бұрын
@@FluxCondenserThat does discourage those of us learning. We need to start somewhere.
@rondeldebbio92193 жыл бұрын
Excellent vid! Really like the the addition of the voltmeter to give true voltage to the test item, since there is a voltage drop across the bulb AND the variac output is not as accurate as the voltmeter.
@FluxCondenser3 жыл бұрын
Thanks, Ron. Glad you liked the video. Yeah, I find that little voltmeter indispensable in this setup.
@mylesmcdonald80622 жыл бұрын
Thank you for the video. I built the DBT and had all the continuity that you showed on the video. The only thing that never worked, was the LED on the switch never lit up. I hooked it up to my Variac and the DUT was an amplifier I am building. The lightbulbs did not glow (60W &^ 100 W), but there was no smoke from my amp. Just not sure if the DBT is working. Thanks Myles
@entoletao Жыл бұрын
wheres the g-o-d damn schematic damn it? ..don't mind the French
@charleswells96823 жыл бұрын
Great video - I will build one. An improvement suggestion: Include a detailed parts list in the video description section especially for those parts that have nontrivial procurement aspects, such as the volt meter, box, cable connectors, bulb socket adapter, etc (yes, everything you gave part numbers for and those things that are less than common).
@FluxCondenser3 жыл бұрын
Thanks, Charles, that’s a good suggestion. I’ll try to put a list together today and will either put it in the description or as a pinned comment.
@JoeJ-82823 жыл бұрын
Also, there is a special glue-in adapter available at Lowes or Home Depot, (or most other electrical supply stores), that you can use with that PVC box that has a rubber insert in the end that has a hole in it that's the same diameter as the round power cord, along with a threaded ring that tightens down onto it so the cord doesn't pull out. It is specifically designed for cords of this round type, and it is an even neater, more professional looking way to do the cord strain relief, and it works just as well as (or even better than), the black push in cable clamp that was used here in this video, except that with the glue-in one you don't have to modify the box hole at all first, you just glue it in with some conduit or PVC glue. The black cable clamp that was used in this video is made specifically for Romex wires going into a metal enclosure such as a breaker panel box.
@edwinatkin52822 жыл бұрын
@@JoeJ-8282 Joe , do you have a model number or picture for this part? I was unable to find it Lowes or Home Depot. Thanks
@jamesdavies6862 жыл бұрын
Nice guide but I cringed at the double ground on the outlet screw, just pigtail it with a lever nut or wire nut.
@FluxCondenser2 жыл бұрын
Absurd comment.
@jamesdavies6862 жыл бұрын
@@FluxCondenser double ground wires on a single outlet screw terminal is against code in just about all 50 states. 4 more inches of spare wire (you had it) and a wire nut and it would have been legal, cleaner, and properly done.
@francescocosoleto2 жыл бұрын
Very nice. What a pity this is a US version only.
@abbywalowen70222 жыл бұрын
Plug on amazon not the same
@ovalwingnut2 жыл бұрын
Is KZbin charging you "by the minute"? Why you felt the need to rush through that explanation is baffling. However, good build.
@iansyme35352 жыл бұрын
Should have used soldered lugs for all switch connections. Just is messy and perhaps not as securely fastened without them. Just my 68yr old tuppenceworth from Scotland ....
@FluxCondenser2 жыл бұрын
Nah.
@iansyme35352 жыл бұрын
@@FluxCondenser Soldered lugs would look neater and give you scope to manouver the positioning to make it look awfully tidy ...
@larrybud23 күн бұрын
Not a fan of this design since the switch is obfuscated by the bulb, but good otherwise.
@LelleKidd2 жыл бұрын
This does not work in Europe. Our contacts are symmetrical, ie neutral and hot can vary.
@FluxCondenser2 жыл бұрын
Uh, obviously.
@darthbubba8663 жыл бұрын
Great vid; but you stole my design from fortyfive years ago. All kidding aside, I'm lazy and have four bulbs already screwed into socket adapters so that I can switch the current limiting quickly. Unfortunately, filament bulbs are starting to get a little scarce.
@FluxCondenser3 жыл бұрын
Ha! You don’t “screw” around!
@andydelle45093 жыл бұрын
Judge: "You are charged with the purchase and use of an incandescent light bulb. How do you plead?" I have noticed though that my Lowe's is now stocking more incandescent bulbs. I guess they got tired of all the returns where the "60watt equivalent" has the light output of a nightlight.
@darthbubba8663 жыл бұрын
@@andydelle4509 Yeah, that "watt equivalent" nomenclature should be banned. Just give the Lumen output - works for incandescent, compact florescent, LED, and the pants-on-fire of the advertisers. The wattage draw is a separate matter, and of interest only to those who pay the electric bill. 😉
@FluxCondenser3 жыл бұрын
Ha! I hear ya. I’m actually all for the transition to more efficient bulbs and with many types in my home I’ve had good luck. But, even now, I’m finding a lot of LEDs just don’t mimic incandescents as claimed. Especially in light output, color and dimming-ability.
@FluxCondenser3 жыл бұрын
Absolutely right, but I think we’ll be stuck with the soon-to-be outdated watt system for quite a while. Getting Americans to change their thinking on that will be like getting them to switch to metric!
@SteveHacker8 ай бұрын
DO NOT use solder on high voltage connections like this!!! NNNOOO!!!
@steverahn49512 жыл бұрын
Talking fast is disturbing and poor example of an instructional video; especially concerning electrical devices!,
@FluxCondenser2 жыл бұрын
Hm. I’ve had no other complaints and many successful builds of the device. Some people need things slowed down quite a bit to process though and you may be among that camp. Consider watching at a reduced speed which KZbin provides an option.
@larrydamuro2393 Жыл бұрын
O
@SteveHacker8 ай бұрын
I will never understand why otherwise great content creators almost always feel the need to use the most obnoxious music possible, thus sending viewers running away, when NO MUSIC would be a much better option… 🤦🏻♂️🤦🏻♂️🤦🏻♂️