The mass hysteria cracks me up. I honestly don't know much of the plumbing codes - that is why I hire a licensed plumber in good standing with the county building department. We have been rounds with the inspectors in the past over small details and everything we do is based on the inspectors interpretation of the code. The inspectors spot check the lines with a level for slope and are generally very happy with this plumbing contractor. Over the years, I've been a part of almost 100 homes that his plumber has helped construct and have had the opportunity to talk with many of the homeowners who have never had any problems. Every State, County, and City is different. We all know that in the end you do what passes inspections, meets budget, and produces a quality product - but that does not look the same on every build. I appreciate all the conversation this has stirred up and hope that overall it is making us all better at what we do. That is the whole point of community collaboration and discussion
@mid-west_man7 жыл бұрын
Daniel Heap , I want to have a bathroom put into my basement, the house is 10 years old, I'm learning listening to people talk that it is not a simple job. I didn't even know there were pumps involved, I guess I will keep taking breaks and going upstairs and using one of the two bathrooms I already have, plus it sounds pretty pricey, great video.
@Iamrichieortiz7 жыл бұрын
Is supostube a 1/8 pitch on 3" and 1/4 on 2" pipe!
@peter58peter7 жыл бұрын
all of the crocks r 'connected'... Not to do job but to rob u of your money.
@stevelovesgod5 жыл бұрын
richard ortiz That's at minimum, you can have a greater pitch, like 3/8" Which is much BETTER
@juliorosenberg99684 жыл бұрын
In my area (Central New York) a home owner can pull out ANY permit on a single family dwelling. No matter how large that residential building may be.
@wonderwilds2 жыл бұрын
most definately helpful. having never seen a real layout, it simplifies it so much vs diagrams.
@Tracyandcrew7 жыл бұрын
Nice video. I was surprised how much you actually knew about the plumbing. I am a Journeyman Plumber and our Jurisdiction code is based on the UPC. Uniform Plumbing Code. I heard that the IRC code has a lot less venting requirements.
@jasonn5530 Жыл бұрын
Excellent thanks for the upload
@Radnally8 жыл бұрын
Thanks. This helps me as I'm adding a bathroom by using an existing room that's on a concrete slab. I know code is a little different everywhere you go. So the basics are what I'm looking for. My local code is 1/8" grade, but 1/4 sounds like a good idea, if I can make it work.
@MrYagga094 жыл бұрын
Thanks for this video it answer an outstanding question I had about my rough ins for a bathroom in my basement. I thought I had to break up the concrete to add a drain for the sink vanity, you explained it at around 2:19. My rough in has the 3 same pipes coming up through the concrete. Thanks.
@astasna7 жыл бұрын
Thank you Daniel, very helpful to make the real things in the field accessible and intelligently explained.
@club-up5 жыл бұрын
I've been in the plumbing/pipefitting business for 43 years. I see 3 corrections there. The 2" should be 3" with a full size clean out. The trap arm for the lavy can only be 3'-6" on 1-1/2" otherwise it has to be 2" at 5'-0". Also the floor drain needs a separate vent. In a basement system you'll need a backwater valve to provent flooding.
@Danfromthenorth842 жыл бұрын
Emergency floor drains don't need a separate vent and you can go 6' on 1 1/2
@club-up2 жыл бұрын
@@Danfromthenorth84 Some codes maybe but not in the UPC. The UPC is the only code I know.
@chillbro22757 жыл бұрын
wow, an objector pit sounds like a good idea! never heard of one before you mentioned it hear Daniel.
@vinnyburdo77104 жыл бұрын
Ejector....
@jamesbeaty48809 жыл бұрын
A couple of comments. Slope on a drain line is very important. 1/4" per foot is ideal when flushing solids. Too little slope and you have sludge building up in your lines. Too much slope and you reduce the drainage capacity of the pipe. This is where your code comes in. If your overall slope exceeds the inside diameter of your pipe, you create a syphon that will suck all the water out of a nearby trap, or make your toilets/sinks gurgle. If you have a 4" ID at 1/4" slope, the max distance you can go without a vent to allow air in is 16'. An 1 1/4" ID is good for 5', a 2" ID is good for 8' etc. I don't have a fancy level like yours, I just tape a 1/2" block of plywood under my 2' level. From the looks of your basement from your main stack to your sump pit, I would say you might be pushing it a bit without an extra vent in that long run.
@matthewkromer92568 жыл бұрын
you do not even know what your talking about not even close
@yazif786 жыл бұрын
James Beaty well you drainage leading towards the municipal system doesn't carry a went the sewer injector already carries a vent , that why on the shower line is wrong
@arnelarsen40733 жыл бұрын
Agree not enough air in your system. Also if you consider from your toilet to sump that is your main drain, any Y connected there needs to have the branch higher then main. So 2” needs to be rotated up so it’s drops into main…Y’s are too flat. You wet vent the shower but toilet has no air.
@jasonn5530 Жыл бұрын
I agree on the slope and vent issues… experience speaks louder than comments on an upload but for sure too much and it sounds like someone is gurgling water… too little and better have the clean out accessible and a snake handy! I tie a vent pipe in all trap areas even if they only vent out of a single stack accept the toilet. Works every time and always aim for 1/4 or just a little more for insurance and haven’t had a problem in 20 yrs
@scottdonahue9193 Жыл бұрын
It's 1/8" per foot by code.. 1/4" per foot on 2" pipe and below
@rayjackson4547 Жыл бұрын
nice job, one question If you have a drain and trap under the water heater in case it fails the p trap is dry. Wont sewer gas come up in to the room?
@DB-dm2xm10 ай бұрын
just fill it up no problem
@TheycallmeDAYZE8610 ай бұрын
Awesome job!
@DirtyDeedsLLC3 жыл бұрын
Nice work. new sub Where is the cleanout
@say_goodnight73426 жыл бұрын
In Kentucky this would be completely wrong, as Kentucky follows it's own plumbing code rather than international code, and is generally considered the strictest state in terms of plumbing code. Here, you have to have an independent vent for each fixture, and no wet vents or flat venting under fixture level rim is allowed at all. Also each fixture had a set trap branch length and fixture unit. (so a shower is considered 1 1/2 fixture unit with a trap size of 1 1/2 minimal, and can only be 3 foot 6 inches of linear pipe between the trap and the vent because a fixture has to hit a vent before it hits a drain.).Also the means of putting pipe underground or under a slab is much stricter (so All the plumbing underground has to be fortified with gravel, so you have to pour gravel all the way around the pipe to stop settling.That doesn't include if you run a pipe under a drive way, in which, it must be concreted around the pipe or it must be cast iron) It's much stricter for plumbers in Kentucky. We have to use much more pipe and fitting than other states, and therefore much more work.
@johnmcook13 жыл бұрын
flowable fill for any pipe conduit included. ;) under road or driveway
@vincentchato5194 жыл бұрын
Ten foot of head pressure on all waste and vent piping. Under ground, release air gaps and us gem caps. Should hold all day but 15 minutes is code in my area.,or until the inspection is done
@Khemrintr4 жыл бұрын
Thanks so much for your video.
@kD_5555_2 жыл бұрын
How come you did not put that 3x3x2 wye so much closer to that 90° off the w.c. you could have saved on so much pipe material?
@brp0u122 жыл бұрын
New home basement rough ins for tube, sink and toilet is venting not needed? I don't have a vent rough in. Is it not needed being these rough ins are last in the system with a low level drain to septic system?
@a_balanced_perspective3 жыл бұрын
How to vent in kitchen waste sink? Independent or together bathroom?
@MisterGreenGuy8 жыл бұрын
Every state is different, but in my area of Texas this would be against code. Water closet too far from vent and water closet would need 4x3 90 with 4 inch stubbed up. Flanged should be installed after concrete pour. But Ive worked in other states where this would be pass no problems and would work no problems. Plumbers who post on youtube videos need to keep in mind that whats going on in a video might be 100 percent up to code in their area.
@joshcowart24465 жыл бұрын
That’s what I was going to say. I would think you’d have to vent the toilet directly out of the toilet line and wet vent it with the lav. Then maybe stack the shower or put it separately in a wall. There’s also no trap primer on the floor drain
@timdouglass64915 жыл бұрын
Where are the vents ?
@DB-dm2xm10 ай бұрын
i didnt notice a clean out either
@khaleefax95533 жыл бұрын
*I am thinking to use a 5 inches schedule 80 for underground plumbing under the basement floor. So that I would, hopefully, never have to dig the basement floor to deal with broken or narrow pipes. Cost doesn't bother me. Are there any other drawbacks to this idea?* *We originally had 3 inches iron pipe under the basement floor and had a nightmare with the kitchen drain that clogged it with grease and all under the basement floor. I don't wanna deal with it again.*
@urielcont77 жыл бұрын
Here in Houston testing pvc with air is a MAJOR NONO!!
@sef22737 жыл бұрын
I’m no pro plumber but what about back filling with pea gravel instead of dirt ?
@stevenking29809 жыл бұрын
In NC all houses used to have a 4" main vent, which is ridiculous. Now we only have to have one 2" vent and the rest of the house can be on studor vents
@ronmexico797 жыл бұрын
Steven King studor vents?? hacks!!
@SylvanTieger6 жыл бұрын
Possibly the plumbing inspectors know about HOARFROST and know 4" vent will not suffer from this condition
@clintdavis95115 жыл бұрын
Steven King Exactly! Back in the 50s in the southeast a one bath house had a 4" cast iron vent on the bathroom. Now you see 2 1/2 bath houses with washer box on a 2" vent.
@nittygrittykitchen5 жыл бұрын
Very helpful, thank you.
@Ajkplumber3 жыл бұрын
My question? If install new fitting ppr water line bathroom ..how much pressuer .do u require to cheak leakge ...???? How much( psi or baar)
@Gacek3gp6 жыл бұрын
Important question why isnt the toilet vented?
@mikerose73754 жыл бұрын
That is a horizontal wet vent system. See it all the time in Oregon. For this system, everything looks ok except for the lav trap arm...sounds too far away. What about a primer valve for the floor drain? Not sure if the floor drain needs a vent and not sure if an ejector pump system needs a back water valve.
@woohunter18 жыл бұрын
Why is there a toilet flange glued on already, would have stubbed up my 4" with a cap and cut it off later after cement.
@timjackson99257 жыл бұрын
woohunter1 state code says you can pull vent to 12 ‘ away from toilet trap
@Montekarlo815 жыл бұрын
woohunter1 he used it as a cap 😂
@clintdavis95115 жыл бұрын
woohunter1 Late to the party but yeah, you stub up and add your flange after the floor is complete.
@Hufdom4 жыл бұрын
Some people know how to read drawings and elevations, when you grow up you'll be able to read them too, and then you can set your flange before the pour.
@woohunter14 жыл бұрын
Kinton K as a 45 year old remodeler, the finished height of the flange depends on the height of the finished floor, there is variances in thickness of tile thin set, etc. I also like to anchor my flanges in the concrete and tile after the tile is set. Why don’t you read up on how to have “friendly” debates.
@stuwinters54758 жыл бұрын
So simple to understand, thanks.
@glennmanchester15688 жыл бұрын
that is a wet vent system although the center line of the 3by 2 wye is a bit far from the toilet here In Fla 5 ft from CL of toilet to CL of wye it's vented. and will work just fine for all 3 fixtures
@raymondallen7168 жыл бұрын
Glenn Manchester i belive it is 6 foot
@ericb56666 жыл бұрын
Its not a wet vent. He said in the video that the vertical 2" pipe is a vent only.
@deaconericb2 жыл бұрын
Vert Nice work
@alyssafaden42233 жыл бұрын
How do you know how deep to dig your trench
@ryanfunk97354 жыл бұрын
How far away is your longest run?? Did you have to measure down from the footer to get how far down the injectore pit has to go down?? In other words if the run is 40 feet, the top of your pipe at the injector pit has to be 10 inches down from footer?. Are you bushing down 2 x 1 1/2 x 1 1/2 tee for your lav and run 1 1/2 vent to tie into your vent going out the house???
@richscountrylife13834 жыл бұрын
No cleanouts?
@TheKing-pp8kz6 жыл бұрын
Can anyone share their professional opinion, is it wise idea to build a basement in a sandy area?
@StephenNu95 жыл бұрын
Nice size bathroom.
@santexfull37387 жыл бұрын
Hi.Good work.And why 2 bars?A little bit of this?We have a sewer pipe not tested.
@chriscary92696 жыл бұрын
this is a horizontal wet vent for a bathroom group which I s legal, one thing I noticed is the 3x2 wye is incorrect, should be 3 inch wye and 3 inch pipe to headed tword the shower and use a 3x2 wye to catch the vent pipe and a 3x2 bushing to catch the shower drain
@ericb56666 жыл бұрын
its not a horizontal wet vent. the vertical 2" is a vent only which makes this all wrong. If a lav was pouring into the vertical 2" it would be better.
@jajagaga89956 жыл бұрын
where is the cleanout? if it is clugged up,
@joevasquez638 жыл бұрын
what is the best easy way to make a house
@minsonzhong98474 жыл бұрын
no Cleanout?
@pdogakron16237 жыл бұрын
use a vibratory compactor, NOT a jumping jack! Unless you want to bust your plumbing connections
@ramazoutieros27817 жыл бұрын
thanks Daniel
@cartoonmark757 жыл бұрын
Great video
@dallenfarmer6 жыл бұрын
Why doesn't the floor drain have a vent?
@erickbecerril125810 жыл бұрын
1. Cleanout required every 40ft if there is more than a 45degree change? 2. Size of vents? 3. Cleanouts at branches over 5ft of main sewer? 4. Long sweeps not hard 45s? 5. Minimum cover? I dig the efforts.
@DanielHeap60Cubits10 жыл бұрын
Erick Becerril I'm honestly not sure on the details about vents and lengths and minimum cover. That is whey I hire a licensed plumber in the area and have the job inspected. this is all flowing to an ejector pit in the basement that pumps to the private septic system.
@hyster25685 жыл бұрын
I thought that every individual fixture has to have its own vent? Another thing, why isn’t that vent rolled on a 45? Again, I’m just asking
@hpman73246 жыл бұрын
Vents need to roll up with 22 1/2 min & no vent on floor drain
@shauntampa6 жыл бұрын
I guess the floor drain doesn’t need a vent? Or the toilet?
@sirbirdtown10303 жыл бұрын
Floor drain needs to vent also
@BigDawgPlumber9123 жыл бұрын
Water closets are trapped but you can either closet 90 or long sweep 90 hope the sewer gas isn’t to bad inside your home
@somaaelsapak63617 жыл бұрын
Very good
@jefflucas721610 жыл бұрын
here in louisiana you can vent a toilet with 2", but when you introduce a shower, lavatory, or floor drain you have to run a 3" vent. the floor drain definitely needs a vent added, as well as a mechanical trap primer. your allowed to make a change of direction with a 45 but your second 45 should have been a wye with a cleanout out the back. we follow a different code than the yankee states. hopefully your plumbing works. its been two years...any problems?
@antoninopezzino5265 жыл бұрын
Why is there no gravel in the basement and no sump and sump pmp. to control the basement water.
@makesumwake8 жыл бұрын
pipes arnt in sand??
@windardarwin59398 жыл бұрын
nice awesome idea
@samuelsaw99077 жыл бұрын
What is a wet vent
@secretsplumbing94567 жыл бұрын
Success in work.
@dimysimplice6 жыл бұрын
Thank you good information may God and Jesus bless you
@bounchofbeaners7 жыл бұрын
its supposed to be an eighth inch of fall for 3 and 4 inch pipe and a quarter inch of fall for 2 inch and 1 and a half pipe..
@Mrwilder20128 жыл бұрын
here in Nevada UPC, I'd wet vent the toilet with the sink, but even then still looks to far.
@henrym027 жыл бұрын
here in canada, that flat vent is not allowed unless is a wet vent, big no, no
@oldhongkong5655 жыл бұрын
It's a huge problem with the shower drain joining the toilet drain horizontally, a portion of toilet waste will overflow into the shower drain. While I'm plumbing my house, I opted to have the shower drain coming into waste drain from above. I don't live in US, so I'm glad not bounding by your country's code
@karenpreston23275 жыл бұрын
That is a good idea
@LS-zx5dc6 жыл бұрын
Pvc test with air? 🤔
@andrewhemans41963 жыл бұрын
It's in the code
@tlgwat10 жыл бұрын
This video is awesome. Thanks for sharing.
@karenpreston23275 жыл бұрын
Toilet is no vented and the vent for the shower need to be put on a 45 degree minimum
@usidesign7 жыл бұрын
thanks
@iceman8462 жыл бұрын
Fail, didn’t roll the wye above center line
@powerwagon37314 жыл бұрын
Flat and wet venting and is not allowed in my area.
@JamesMesidor6 жыл бұрын
Thanks for the info
@shawnfairbanks93397 жыл бұрын
That is a horizontal wet vent system. It's funky as shit and I don't really like it but I've done it on multistory buildings. It. Ugh me every time I see it but we're all just used to conventional plumbing. Technically it's right though. As for traditional plumbing, technically the shower is fine. If your trap arm is twice the size as required then you don't need a vent (which technically I think it needs a 4" arm and trap)🤔. 2% required on all pipe less than 4" though and it's not permitted to test plastic pipe with air.
@shawnfairbanks93397 жыл бұрын
Now that I think about it though that vent is supposed to be larger. And have a clean out on it. So it is wrong. The concept is legal but.
@rorybellamy25339 жыл бұрын
Wash sink drain?
@juliorosenberg99684 жыл бұрын
I am a self employed plumber with 32 years experience. I still HATE doing Slab work!!! Nothing to measure off 😒😒
@ironicalitis10484 жыл бұрын
Your codes are so different then around here
@drewfaulkner32426 жыл бұрын
1. THIS WAY IS ILLEGAL IN NEW MEXICO. 2. THE PIPE WAS NOT LABELLED AS PRESSURE PIPE. MOST PIPE I RUN IS NOT FOR PRESSURE SO YOU CAN NO PUT IT ON AIR TEST. HAS TO BE WATER TESTED.
@jameshudson54618 жыл бұрын
Old video but this is correct plumbing in Michigan. Master plumber myself and I understand codes vary geographically and I've done this 100's of times I'm sure it works 100% I've plumbed in Kentucky and this wouldn't pass inspection. The codes their are insanely overkill!
@MisterGreenGuy8 жыл бұрын
Same in Texas. That would get a redtag (code rejection) here. Water closet too far from vent and water closet would need 4x3 90 with 4 inch stubbed up. Flanged should be installed after concrete pour.
@marqueemark59178 жыл бұрын
In AZ its not even close to a green tag haha
@raymondallen7168 жыл бұрын
James Hudson i live in south Florida we used to be under the south Florida building code but now we are under the national code
@marqueemark59178 жыл бұрын
Raymond Allen UPC or national code book ..all the same . That shitter is not vented correctly .. End of story
@williamdavidson90097 жыл бұрын
Sure am glad I live where there are no inspections of residential plumbing...if it works it is OK
@XX-ld7hw7 жыл бұрын
Good video but I would add that your measurements are "to center", for instance your closet, the 12in should be "to center" not just "12 inches from the finished wall" because some people might take that as the edge closest to the wall should be 12 inches and then you would be off when do your top out. I'm learning to be a plumber also so I don't know everything but I do know that.
@kD_5555_2 жыл бұрын
A handy Andy will think like that.
@getlost77998 жыл бұрын
thank you, nice video.
@JorgeRodriguez-xk6fv8 жыл бұрын
They way the plumbers roughed it out is very wrong and illegal here in Texas. Vent should be 3" and has to be above the plumbing fixtures thats considered a low vent
@seanmulholland75976 жыл бұрын
Cod is 17-19 of wall
@joetheboxer13610 жыл бұрын
no pebbles? the main run might sink
@DanielHeap60Cubits10 жыл бұрын
JoeThe Boxer In many areas in Colorado we do use "squeegie" or pea pebbles for a base but not at this particular site. The earth is very sandy and compacts easily.
@bodyman13110 жыл бұрын
***** anyway that's in the US not in Australia
@joetheboxer13610 жыл бұрын
***** Anyway, yours is different ,but for Australia ,Victoria you need to have 75 mm of pebbles under your pipes and 100 mm of concrete under all 90 degrees bent and every P-traps and your pipes need to be very straight , because the inspectors used mirror to check them.
@DanielHeap60Cubits10 жыл бұрын
That's good to know. I'm going to research this more. I may be changing my requirements for my plumbers going forward based on this. Thanks for the info.
@stevenking29809 жыл бұрын
It'll never sink. In 3o years of plumbing it's never happened to anyone I've ever known.
@stormbytes6 жыл бұрын
Really helpful. Thanks!
@deechicago258 жыл бұрын
Where did he say adding the lav tho?on the vent ?
@karenpreston23275 жыл бұрын
Ye dirt arm call wet vent. Vent has to increase one size which it does so that would be legal 1-1/2 inch drain line to 2" pipe would be legal
@andyz27475 жыл бұрын
That's why people don't hire license plumber anymore because of this type of videos people think it easy and tried to do themselves but when the inspector inspect the job it have to be redone
@karenpreston23275 жыл бұрын
Or the inspector pass it because he or she doesn't know what there talking about ether lol
@harrisonsplumbing85557 жыл бұрын
vent cannot be ran flat or dry, the venting is illegal, and the floor drain must have a vent within 16 feet on 3" which i don't see that either, 3" pipe 1/8" per foot grade is required, anything below 3" is 1/4" per foot anything above 6" is 1/16" per foot
@harrisonsplumbing85557 жыл бұрын
if that were a wet vent tying into a lavatory it would be legal, but you just said vent, but im assuming thats for a vanity
@fottisfortunaadiuvat65003 жыл бұрын
Only 2"Pipe comes whith 1/4 Buble level the 3 inches Pipe hora whit 1/8 Buble level
@joetheboxer13610 жыл бұрын
you have to put concrete under under the p traps and those bent coming up
@hyster25684 жыл бұрын
In Texas you have to roll that vent on a 45 and a sweep for the toilet!! Also, every fixture has to have its own vent!!
@jklsr559 жыл бұрын
See!!? This is exactly what I spoke of. Most of the items mentioned here dance around the UPC. But each municipal contingent has their own idiosyncrasies they feel need updating at further attention. Remember, the code is nothing more than industry MINIMUMS... Some jurisdictions address things further. They are the people you need to make happy. Not these blow hard plumbers prowling KZbin dispensing their worthless knowledge.
@raymondallen7168 жыл бұрын
Jeff Legg a lot of these licensed journeyman plumbers don't know their ass from a hole in the wall
@steviesevieria18683 жыл бұрын
Both of you are correct!
@ewithers898 жыл бұрын
this is typical in NC, minus the floor cleanouts. I would think of at least 2 being required in that long run.
@crystaryl11767 жыл бұрын
nice! thank you.
@TH0MASBR00KS2 жыл бұрын
👍💥👍👍
@chadsimmons63476 жыл бұрын
This ground-work,should be laid on a bed of gravel,and not on the dirt! if the ground gets wet below the concrete-slab it could sink causing the piping to sag and clog up over time,there should be at least 3-inches of gravel below the ground work plumbing
@JCcanU6 жыл бұрын
Missouri my area has no code , I have owned 2 homes , the last home I redid the plumbing 2001 in and out to the septic , no vets the only vent was from the laundry room drain pipe 1-1/2 for the washer, kitchen and bath room, 3 sinks tub shower toilet all off the 1 vent 50 foot away i could smell crap in the laundry room , the septic had 1 lateral 100 foot long . House 2 . has" 2 AAV vents" on the 4 inch main #1 is at the footing on a 2 inch vent pipe with a T off the 4" main only 2 inch long . #2 five foot behind the toilet from kitchen 2 inch line tied into the main with a stack of reducers 2"to 4" , kitchen sink not vented at all not even a aav vent sink vapor locks and they had a dishwasher hooked up , under the sink 2 P traps and between them a pipe cut 3 inch short with a no hub band not even enough to tie the ends in. I had my Journeyman in plumbing 20 years ago in Michigan so I still plum to codes that are from 1987 to 2001 . I have seen garden hose hooked up to hot water tank run to a kitchen 100 foot behind walls . and you all are saying his is bad lmao im redoing this house looking up new codes see how much stuff has changed in 20 years. The Hardware is so far behind the times they still have stuff from 1952 on the shelfs , when you ask for something they have to order it . home depot is 100 miles away . they do not carry any Y at all they only have T to get a 90 you have to tie to 45 together they never seen it done they just use a 90 on 4 inch main ask for a long 90 they look at you like your dumb .
@leopoldomreyes8214 жыл бұрын
Te faltaron muchos repiraderos y mas importanta el del toile
@بساطةامرحاب2 жыл бұрын
👍 👍 👍 👍 👍
@Questchaun6 жыл бұрын
Not sure how I'd feel about pressurized shit pumped through the floor joists.