C-More Micro HMI First Program Create

  Рет қаралды 13,611

ACC Automation

ACC Automation

Күн бұрын

Пікірлер: 10
@philliptwin326
@philliptwin326 4 жыл бұрын
Thanks for your great vidios Gary, I really appreciate your effort...I have one question, well I have an EA7-TC6L HMI and I was attempting to communicate my HMI with the do-more designer simulator and I followed exactly the same steps as your video but at the end I didn't have communication between them, so I would wanna know how can I achieve that, please, I configured the modbus TCP/IP like you and the HMI just displays that "PLC communication time out" and I don't know why, could you help me with this? please, greetings sir.
@ACCautomation
@ACCautomation 4 жыл бұрын
Hi Felipe, I have not used the EA7-TC6L. It says in the specification that it will communicate Modbus TCP via the Ethernet port. Please ensure that you are setting the correct IP address for your computer in the HMI software. cdn.automationdirect.com/static/manuals/eauserm_12_09/eauserm_12_09.html Since this is an older C-More HMI, you must ensure that the ethernet cable is a straight-through if using a switch in between the Computer and HMI. If a direct connection is made then a Crossover cable must be used. See Chapter 8: Troubleshooting - 8-15 to 8-17 I hope this helps you out. Regards, Garry
@marioaguilar6677
@marioaguilar6677 Жыл бұрын
Hi, what can i do to make the HMI return automatically to the main screen after a time of being changed for example to screen#2
@ACCautomation
@ACCautomation Жыл бұрын
Hi @marioaguilar6677 The following post will show you the Panel to PLC and PLC to Panel communications. accautomation.ca/c-more-micro-hmi-first-program-part-2/ This is shown under the heading PLC to Panel / Panel to PLC. There is a location that can be set for the current screen. Create the PLC logic that compares the screen to 1. (Page 1). If it is not, then set a timer. After the timer expires, then set the page to 1. I hope this helps you out. Regards, Garry
@ACCautomation
@ACCautomation 6 жыл бұрын
Version v4.32 of the C-More Micro Programming Software has just been released. Download the latest version: support.automationdirect.com/products/cmoremicro.html Regards, Garry
@woopass100
@woopass100 4 жыл бұрын
can you link the c-more demo version to the Do-more demo version?
@ACCautomation
@ACCautomation 4 жыл бұрын
Hi Robert, Unfortunately, the C-More software's simulator will only allow manual entry. You need the HMI hardware to connect to the Do-More Simulator. Note: The Do-more Simulator will only run for a few hours before returning to program mode. You must then put it back in run mode. If you are looking to try something out, AdvancedHMI can be used to communicate to the Do-More Designer Simulator. accautomation.ca/create-a-plc-with-hmi-training-and-learning-environment-free/ Regards, Garry
C-More First Program - EA9 HMI Series Panel
11:03
ACC Automation
Рет қаралды 25 М.
C-More EA9 HMI Series Panel Common Screen Menu
12:09
ACC Automation
Рет қаралды 3,8 М.
Will A Guitar Boat Hold My Weight?
00:20
MrBeast
Рет қаралды 196 МЛН
How Strong is Tin Foil? 💪
00:26
Preston
Рет қаралды 71 МЛН
Electric Flying Bird with Hanging Wire Automatic for Ceiling Parrot
00:15
C-More Micro HMI Object Buttons and Indicators
27:20
ACC Automation
Рет қаралды 1,6 М.
Productivity 1000 Series PLC First Program
10:41
ACC Automation
Рет қаралды 19 М.
Do More Designer Counters
9:00
Grounded Electrical Solutions
Рет қаралды 2,9 М.
C-More EA9 HMI Series Panel to PLC and PLC to Panel Settings
14:17
ACC Automation
Рет қаралды 18 М.
C-More EA9 HMI Series Panel Communication and Updating Firmware
8:29
ACC Automation
Рет қаралды 10 М.
C-More EA9 HMI Series Panel System Setup Screens
8:51
ACC Automation
Рет қаралды 6 М.
C-More HMI Programming
35:14
ControlsFreak
Рет қаралды 5 М.
Click PLC Send and Receive Serial Communication Instructions
11:01
ACC Automation
Рет қаралды 29 М.
Will A Guitar Boat Hold My Weight?
00:20
MrBeast
Рет қаралды 196 МЛН