C-Rate Heat Generation Per Unit Volume & Heat Flux for CFD Simulation of Lithium Ion Battery ||

  Рет қаралды 2,454

Frontiers In CFD

Frontiers In CFD

Күн бұрын

Пікірлер: 41
@swagatagupta3969
@swagatagupta3969 Ай бұрын
How do you get the convective heat transfer coefficient or just take it as a random value ? I we dont add convection is there any problem ?
@FrontiersInCFD
@FrontiersInCFD Ай бұрын
Need to calculate not a random value..
@emrysdruid143
@emrysdruid143 9 ай бұрын
How to incorporate the condition of charging and discharging in this? Or we need to use some other method or model?
@FrontiersInCFD
@FrontiersInCFD 9 ай бұрын
No just heat generation per unit volume is specified based on c rate
@emrysdruid143
@emrysdruid143 8 ай бұрын
@@FrontiersInCFD which model can we use for charging and discharging simulations??
@FrontiersInCFD
@FrontiersInCFD 8 ай бұрын
@@emrysdruid143i have use c rate
@emrysdruid143
@emrysdruid143 8 ай бұрын
@@FrontiersInCFD Yes sir you have used C rate I know.....but if my query is if we want to simulate charging and discharging, then what do we need to do in that case?
@Sumitkoundalvlogs
@Sumitkoundalvlogs Ай бұрын
Hello sir the values you have taken from the paper doest it gives the same reault like temperature and reynolds no value
@FrontiersInCFD
@FrontiersInCFD Ай бұрын
These are reference values taken for simulation. May have variation
@Sumitkoundalvlogs
@Sumitkoundalvlogs Ай бұрын
How can i contact you i want to asked you about some ansys problem and something
@Sumitkoundalvlogs
@Sumitkoundalvlogs Ай бұрын
​@@FrontiersInCFD in research paper temperature exceed up to 312k how to achieve that what changes should i need to do to get the same exact value from the paper
@FrontiersInCFD
@FrontiersInCFD Ай бұрын
Connect on whats app 9834584778
@rebookspartan
@rebookspartan 9 ай бұрын
If I set up the heat fluxe in this way, can I obtein the maximum temperature of the cells?
@FrontiersInCFD
@FrontiersInCFD 9 ай бұрын
You can get in result section you have to select domain as cell
@rebookspartan
@rebookspartan 9 ай бұрын
sorry, I explained myself poorly, I simulated a cell by setting the heat generation with forced convection, recreating the real conditions, I obtained a surface temperature of the cell higher than in reality: in reality I obtained 35 C° while in the simulation 60 C°, therefore I asked myself is it correct to simulate the cell in this way?
@FrontiersInCFD
@FrontiersInCFD 9 ай бұрын
Checl the time step size you have use
@q.t.v
@q.t.v 9 ай бұрын
pleas can you explain how get the value of heat generation or the the value if heat transfer , h know the P=i.v , BUT SEEM THAT YOU DIDNT USE ONLY THIS EQUATION.
@yahya-youcef
@yahya-youcef 9 ай бұрын
???
@FrontiersInCFD
@FrontiersInCFD 9 ай бұрын
Took heat generatiom per unit volume from reference paper
@q.t.v
@q.t.v 9 ай бұрын
please doctor, can you answer me
@kevintimothy29
@kevintimothy29 8 ай бұрын
you can use bernardi equation for that. you may find this equation in internet and many research paper use this equation
@FrontiersInCFD
@FrontiersInCFD 8 ай бұрын
@@q.t.v took from reference paper
@amansworld212
@amansworld212 10 ай бұрын
Sir you haven't selected the polarity of each cell i mean where is positive/negative terminal?
@FrontiersInCFD
@FrontiersInCFD 10 ай бұрын
I haven't used MSMD model this is just CFD thermal Analysis.
@amansworld212
@amansworld212 10 ай бұрын
@@FrontiersInCFDOhk.. sir please mention your linkdin user name
@FrontiersInCFD
@FrontiersInCFD 10 ай бұрын
www.linkedin.com/in/dr-roshan-bhagat-83b79a146/
@amansworld212
@amansworld212 10 ай бұрын
can i design 4P23S battery pack in Ansys
@FrontiersInCFD
@FrontiersInCFD 10 ай бұрын
Yes it can be done
@amansworld212
@amansworld212 10 ай бұрын
@@FrontiersInCFD ooh nice..for thermal analysis is it required to give the space between each battery?
@FrontiersInCFD
@FrontiersInCFD 10 ай бұрын
For effecrive heat transfer it is required
@amansworld212
@amansworld212 10 ай бұрын
@@FrontiersInCFD If we do not give a gap then the length of the battery pack will be too much. If the width is so wide then how can it be made to work?
@FrontiersInCFD
@FrontiersInCFD 10 ай бұрын
These gaps are in ""mm""
@KundanKumar-rv8gq
@KundanKumar-rv8gq 9 ай бұрын
Sir , you done simulation for smaller time step ,but when I did at 5c, 720 sec , at 600 sec there is spike in temperature, itried to change mesh size and timestep =0.5 , still problem , can you tell me , where I am doing wrong,I have got all the solution till 4c
@FrontiersInCFD
@FrontiersInCFD 9 ай бұрын
Take smaller time step size of 0.005
@MuhammadArslanAslam-yu4fg
@MuhammadArslanAslam-yu4fg 8 ай бұрын
Brother can you solve this tutorial using PCM material. please brother
@FrontiersInCFD
@FrontiersInCFD 8 ай бұрын
Will try
@anfalacademy786
@anfalacademy786 10 ай бұрын
Sir Can u mention research paper
@FrontiersInCFD
@FrontiersInCFD 10 ай бұрын
Received as simulation requirement however this was used as one of the reference paper. Numerical and experimental investigation of thermal performance of lithium ion battery with hybrid cooling system under dryout condition
How a Lithium Ion Battery Actually Works // Photorealistic // 16 Month Project
17:27
24 Часа в БОУЛИНГЕ !
27:03
A4
Рет қаралды 7 МЛН
БОЙКАЛАР| bayGUYS | 27 шығарылым
28:49
bayGUYS
Рет қаралды 1,1 МЛН
Thermal management of lithium ion batteries: the sub-system optimisation trap!
16:59
Electrochemical Science and Engineering
Рет қаралды 2,1 М.
Why Synopsys Bought Ansys (For $35 Billion)
14:07
Asianometry
Рет қаралды 216 М.
Keep Your Cool: Electric Vehicle Battery Cooling Methods
38:40
Munro Live
Рет қаралды 91 М.
How to Make a Real Diamond - (Not Clickbait)
8:51
JerryRigEverything
Рет қаралды 4,9 МЛН
Inside the V3 Nazi Super Gun
19:52
Blue Paw Print
Рет қаралды 2,6 МЛН
24 Часа в БОУЛИНГЕ !
27:03
A4
Рет қаралды 7 МЛН