Thanks for doing this. Only professional video find in KZbin for triaxial test.
@tapashbarman61969 ай бұрын
Nice explanation
@teebamohammad71424 жыл бұрын
Good and nice work
@paulkossik2 жыл бұрын
I didn't see you tighten the compression bolts where the lines enter the top cap. Am I thinking of a different model of top cap?
@paulkossik2 жыл бұрын
I ask because I use older equipment that I repair myself, so leaks during saturation and consolidation are a big pain. It may not happen with new lines and o-rings.
@willliamkitch29672 жыл бұрын
This cell does not use compression fitting for the drainage line in the top cap. The seal is accomplished using only o-rings. Works fine.
@geotechnical3422 Жыл бұрын
sir plz next part
@scientificresearch14004 жыл бұрын
sir ,is this membrane permeable
@geotechnicallabvideos27204 жыл бұрын
It really shouldn't be.
@fred1111582 жыл бұрын
No, it is not
@Ahmed-vx6qc2 жыл бұрын
No, the membrane must be insulating, and accordingly, the water inside the sample will exit through a special channel located at the bottom or top, and possibly the bottom and top together to let the water out in a faster time. The water inside the sample must exit through a special channel (exclusively), to be able to know the change The volumetric, where this water will come out and collect in a graduated cylinder, as well as this special channel is equipped with a gauge to read the pressure of the pore water, and all these achievements can not be obtained if the membrane surrounding the sample is permeable to water.