CARA PEMILIHAN SEBAGAI SUIS UTAMA PADA KOTAK AGIHAN PENGGUNA . V64

  Рет қаралды 16,987

KITA BUAT KITA BIKIN

KITA BUAT KITA BIKIN

Күн бұрын

Пікірлер: 83
@haz-u1x
@haz-u1x 9 күн бұрын
aku suka cara dia bercakap 😊
@xazutarq3052
@xazutarq3052 3 жыл бұрын
Penerangan yang jelas dan meyakinkan.tahniah.
@KITABUATKITABIKIN
@KITABUATKITABIKIN 3 жыл бұрын
TERIMA KASIH SUPPORT CHANNEL KITA BUAT KITA BIKIN 🤝
@KITABUATKITABIKIN
@KITABUATKITABIKIN 3 жыл бұрын
SEMOGA BERMANFAAT 👍
@hasmizahabdul2867
@hasmizahabdul2867 3 жыл бұрын
@@KITABUATKITABIKIN bkn jnis isolator xblh la
@KITABUATKITABIKIN
@KITABUATKITABIKIN 3 жыл бұрын
@@hasmizahabdul2867 Jenis Isolator Tidak Boleh Digunakan Sebagai SUIS UTAMA .
@azmankhamis6012
@azmankhamis6012 2 жыл бұрын
@@KITABUATKITABIKIN ggu ini
@karlmahat4606
@karlmahat4606 Жыл бұрын
Terbaik la . Senang faham
@KITABUATKITABIKIN
@KITABUATKITABIKIN Жыл бұрын
semoga Bermanfaat 👍
@KITABUATKITABIKIN
@KITABUATKITABIKIN Жыл бұрын
TERIMA KASIH SUPPORT CHANNEL KITA BUAT KITA BIKIN 🤝
@MNASIR-pw1rn
@MNASIR-pw1rn 3 жыл бұрын
Terima kasih atas perkongsian ini.
@KITABUATKITABIKIN
@KITABUATKITABIKIN 3 жыл бұрын
Sama2 Encik.
@KITABUATKITABIKIN
@KITABUATKITABIKIN 3 жыл бұрын
TERIMA KASIH SUPPORT CHANNEL KITA BUAT KITA BIKIN 🤝
@KITABUATKITABIKIN
@KITABUATKITABIKIN 3 жыл бұрын
SEMOGA BERMANFAAT 👍
@MNASIR-pw1rn
@MNASIR-pw1rn 3 жыл бұрын
@@KITABUATKITABIKIN sama2
@narma1092
@narma1092 Жыл бұрын
Ngeeeeeeeee... 😁👍😁👍😁👍
@KITABUATKITABIKIN
@KITABUATKITABIKIN Жыл бұрын
TERIMA KASIH SINGGAH DI CHANNEL KITA BUAT KITA BIKIN 🤝
@alphagamers6568
@alphagamers6568 2 жыл бұрын
Terbaik boskuuu
@KITABUATKITABIKIN
@KITABUATKITABIKIN 2 жыл бұрын
TERIMA KASIH SUPPORT CHANNEL KITA BUAT KITA BIKIN 🤝
@KITABUATKITABIKIN
@KITABUATKITABIKIN 2 жыл бұрын
Semoga Bermanfaat 👍
@alphagamers6568
@alphagamers6568 2 жыл бұрын
@@KITABUATKITABIKIN bos nak tanya, mana lagi bagus 6kA atau 4.5kA Dan apa beza kedua ni bos?
@KITABUATKITABIKIN
@KITABUATKITABIKIN 2 жыл бұрын
4.5 kA utk Dosmetik 6kA utk industrial
@KITABUATKITABIKIN
@KITABUATKITABIKIN 2 жыл бұрын
4.5 kA ialah 4500 Ampere dan 6 kA ialah 6000 Ampere .
@azrolburn6307
@azrolburn6307 Жыл бұрын
bang..tanyr cikit..rumah sya ni ada elcb saja..kira ok ke? dan cdg nak tukar elcb tu ke 63a dri 40a sebab nak tambah mcb utk lampu dan plug point..boleh kan?
@KITABUATKITABIKIN
@KITABUATKITABIKIN Жыл бұрын
Saya cadangkan Letak Suis utama ikut peraturan Elektrik .
@KITABUATKITABIKIN
@KITABUATKITABIKIN Жыл бұрын
Jika nak tukar ELCB Dari 40 Amp Ke 63 Amp Pastikan Kabel Utama Saiz 16 mm ( KABEL dari Meter ke DB Board ) .
@KITABUATKITABIKIN
@KITABUATKITABIKIN Жыл бұрын
Semoga Bermanfaat 👍
@KITABUATKITABIKIN
@KITABUATKITABIKIN Жыл бұрын
TERIMA KASIH SUPPORT CHANNEL KITA BUAT KITA BIKIN 🤝
@boyahugahugawekwek2847
@boyahugahugawekwek2847 2 жыл бұрын
Salam...sy nak pasang sub db..main db guna main switch c32..perlu ka sy tukar ke c63 atau perlu ikut rate fius cut out tnb..kalau tnb hanya bagi 32A pada fius, adakah sy xboleh guna C63? 1 lagi..sy ada beli maxguard MCB 2 pole C40, tp pada body hanya tulis 415V dengan code 60898 sahaja...boleh kah digunakan utk ganti main switch c32 pada main db?
@KITABUATKITABIKIN
@KITABUATKITABIKIN 2 жыл бұрын
WALAIKUMUSALAM .
@KITABUATKITABIKIN
@KITABUATKITABIKIN 2 жыл бұрын
Soalan pertama : Nak Buat DB sediakala Jadi Main DB dan Tambah satu DB menjadi SUB DB . Untuk MAIN DB Pastikan MAIN KABEL Dr METER ke MAIN DB Saiz 16 mm Dan MAIN SWITCH Dan RCCB/ELCB SAIZ 63Amp . Dan Pastikan FIUS Pada CUT OUT 63 Amp .
@KITABUATKITABIKIN
@KITABUATKITABIKIN 2 жыл бұрын
Dan Pastikan KABEL Dari Tiang Ke CUT OUT SAIZ 16 mm Jika Rumah Lama Atau Kampung masih Guna KABEL Dr Tiang Ke CUT OUT saiz Kecil itu Tidak Sesuai Utk Rumah yg menggunakan Beban Banyak.
@KITABUATKITABIKIN
@KITABUATKITABIKIN 2 жыл бұрын
Utk soalan ke2 : Boleh Guna MCB 2pole maxguard
@KITABUATKITABIKIN
@KITABUATKITABIKIN 2 жыл бұрын
Semoga Bermanfaat 👍
@zambrishaimi8062
@zambrishaimi8062 Жыл бұрын
Assalamualaikum tuan .mcb 32a 1 pole boleh guna tak utk main switch.?
@KITABUATKITABIKIN
@KITABUATKITABIKIN Жыл бұрын
WALAIKUMUSALAM , Bagi Saya Boleh . Tak ada Masalah
@KITABUATKITABIKIN
@KITABUATKITABIKIN Жыл бұрын
TERIMA KASIH SUPPORT CHANNEL KITA BUAT KITA BIKIN 🤝
@zambrishaimi8062
@zambrishaimi8062 Жыл бұрын
@@KITABUATKITABIKIN t.kasih tuan
@shahrulnasirchannel2203
@shahrulnasirchannel2203 Жыл бұрын
Jadi mcb 2 pole nak pakai berapa A ye. 40 atau 63
@KITABUATKITABIKIN
@KITABUATKITABIKIN Жыл бұрын
Jika kabel utama Dr meter DB saiz 16mm saiz MCB 2pole 63Amp .. saiz kabel utama 10mm MCB 2pole saiz kabel 40Amp
@KITABUATKITABIKIN
@KITABUATKITABIKIN Жыл бұрын
TERIMA KASIH SUPPORT CHANNEL KITA BUAT KITA BIKIN 🤝
@shahrulnasirchannel2203
@shahrulnasirchannel2203 Жыл бұрын
@@KITABUATKITABIKIN terima kasih atas jawapan. 👍
@adikzam1619
@adikzam1619 2 жыл бұрын
Tuan, Saya ingin tambah Sub DB setelah renovate umah dan Main DB saya yg asal pakai ELCB 40A dan Main Switch 32A? Adakah sesuai untuk tambah sub db, Main Switch c40 dan ELCB 40A 100ma? Wireman sebelum ni dia main looping je, smpai kan C10 dia share 10 lampu 2 kipas ceiling dan water heater?
@KITABUATKITABIKIN
@KITABUATKITABIKIN 2 жыл бұрын
Main DB harus guna 63 Amp MAIN SWITCH dan RCCB / ELCB .
@KITABUATKITABIKIN
@KITABUATKITABIKIN 2 жыл бұрын
Main DB harus guna 63 Amp MAIN SWITCH dan RCCB / ELCB . SUB DB guna 40 Amp MAIN SWITCH Dan RCCB / ELCB
@KITABUATKITABIKIN
@KITABUATKITABIKIN 2 жыл бұрын
Saiz KABEL UTAMA Utk METER KE MAIN DB Guna SAIZ 16 mm
@KITABUATKITABIKIN
@KITABUATKITABIKIN 2 жыл бұрын
Saiz KABEL UTAMA Utk METER KE MAIN DB Guna SAIZ 16 mm .. SUB DB Guna SAIZ 10 mm
@KITABUATKITABIKIN
@KITABUATKITABIKIN 2 жыл бұрын
Untuk LITAR yang Guna C10 yang Campur lampu , kipas dan water Heater wajib Asingkan
@banitamim3905
@banitamim3905 Жыл бұрын
buka kelas dak tuan? sy nak belajar
@KITABUATKITABIKIN
@KITABUATKITABIKIN Жыл бұрын
Maaf Saya Tak Buka Kelas
@KITABUATKITABIKIN
@KITABUATKITABIKIN Жыл бұрын
TERIMA KASIH SUPPORT CHANNEL KITA BUAT KITA BIKIN 🤝
@banitamim3905
@banitamim3905 Жыл бұрын
@@KITABUATKITABIKIN Baik tuan . Terima kasih teruskan sebarkan ilmu 👍👍👍
@ahmadrazman228
@ahmadrazman228 7 ай бұрын
yg bercakap ni robot ke?
@tarmizichannel
@tarmizichannel 2 жыл бұрын
bos, cakap macam biasa dah.jgn macam robot..hihi.maaf ye.
@KITABUATKITABIKIN
@KITABUATKITABIKIN 2 жыл бұрын
Ok Baik , TERIMA KASIH SUPPORT CHANNEL KITA BUAT KITA BIKIN 🤝
@ridwanoppa269
@ridwanoppa269 3 жыл бұрын
kenape ckp sangkut2 . biase2 dh la boss..
@KITABUATKITABIKIN
@KITABUATKITABIKIN 3 жыл бұрын
Maaf , sy cuba berbaiki Dr segi audio , Terima kasih atas respon bos.
@ridwanoppa269
@ridwanoppa269 3 жыл бұрын
@@KITABUATKITABIKIN HARAP BOSS TAK TERASE HATI,DARI SEGI DETAIL MEMANG TERBAIK. NY TANYE BOS UNTUK 3HP WATERPUMP 13.86A SAIZ MCB APE YG SESUAI..
@KITABUATKITABIKIN
@KITABUATKITABIKIN 3 жыл бұрын
@@ridwanoppa269 WATER pump 3fasa kan
@ridwanoppa269
@ridwanoppa269 3 жыл бұрын
@@KITABUATKITABIKIN 1phase
@KITABUATKITABIKIN
@KITABUATKITABIKIN 3 жыл бұрын
@@ridwanoppa269 saiz MCB C16 Atau C20 Saiz KABEL 4 mm .
Tutorial asas pemasangan kotak pengagihan elektrik satu fasa
20:05
ABR USAHA ELEKTRIK
Рет қаралды 14 М.
PAPAN SUIS UTAMA (PSU@MSB)
51:07
SOUDIQQIN sod
Рет қаралды 2,3 М.
Арыстанның айқасы, Тәуіржанның шайқасы!
25:51
QosLike / ҚосЛайк / Косылайық
Рет қаралды 700 М.
Сестра обхитрила!
00:17
Victoria Portfolio
Рет қаралды 958 М.
Ilmu Nak Fitting DB Kemas, Selamat Dan Cepat
17:53
Zahran Engineering
Рет қаралды 34 М.
PAPAN SUIS PENGGUNA MENGIKUT GARIS PANDUAN SURUHANJAYA TENAGA | DIDIKTV
11:30
Wiring SUB DB (MALAYSIA)
20:19
mr saiful77
Рет қаралды 106 М.
Ape kesan jika saiz MAIN SWITCH besar & load/beban kecik jer???
14:21
MADIL ENGINEERING
Рет қаралды 36 М.
FUNGSI Dan KEGUNAAN ELCB 100 mA , 30 mA Dan 10 mA Untuk.... . V59
9:57
KITA BUAT KITA BIKIN
Рет қаралды 15 М.
Cara fitting Db Board 26way dengan betul dan kemas
12:50
Zamil channel
Рет қаралды 3,6 М.
Cara Pemasangan Kotak Agihan 1 Fasa KOZUKA
15:44
DIY Asal Boleh
Рет қаралды 16 М.
CARA MENENTUKAN SAIZ MCB UNTUK LITAR PENDAWAIAN DAN BEBAN . V62
10:31
KITA BUAT KITA BIKIN
Рет қаралды 27 М.
Jarang Saya Marah Bila Saya Buat Inspection Wiring Rumah. Tapi Kali Ini Saya Marah.
26:06
IAZ ELEKTRIK POWER ENTERPRISE IAZ ELEKTRIK
Рет қаралды 14 М.