Cavitation in Centrifugal pump, NPSH available, NPSH required, Calculation of NPSH, NPSH3

  Рет қаралды 22,109

Concept Connect (Chintan Modi)

Concept Connect (Chintan Modi)

Жыл бұрын

This video deals with basics concept behind Net positive suction head available & required like Vapour pressure, Bernoulli's principle, Cavitation, NPSH3 concept, NPSHr concept, NPSH available calculation.
#GATE #GATE2023 #CHEMICALENGINEERING #PROCESSENGINEERING #NPSH #JOBINTERVIEWQUESTIONS

Пікірлер: 48
@Eagle_1174
@Eagle_1174 18 күн бұрын
Je baat....
@yashgoel25
@yashgoel25 Жыл бұрын
Quite elaborative and neatly explained Sir. These are some of the most important concepts which are asked in Process Engineering Job Interviews and you made them look so easy!
@chintanconcept
@chintanconcept Жыл бұрын
Thanks Yash !! Good to hear from you 👍🏻👍🏻
@mayukhchakroborty2985
@mayukhchakroborty2985 Ай бұрын
The way you were described it was just awesome.
@chintanconcept
@chintanconcept Ай бұрын
Glad you think so!
@YashPatel-uq3xh
@YashPatel-uq3xh Жыл бұрын
Very Understandable & Informative
@amanjit.8885
@amanjit.8885 6 ай бұрын
Amazing video sir there is no any comparison with other sir in this KZbin market 🎉🎉
@tusharkdalbehera313
@tusharkdalbehera313 7 ай бұрын
watched many videos but this one is one of the clearly explained and easy to understand
@Sqb1998
@Sqb1998 10 ай бұрын
Excellent lecture bro... Pls keep it up
@dibyaranjanojha5757
@dibyaranjanojha5757 4 ай бұрын
Awesome
@samirjariwala3437
@samirjariwala3437 Жыл бұрын
Really connected with concept 🎉
@chintanconcept
@chintanconcept Жыл бұрын
Thanks Sir
@user-qe6xr6me4p
@user-qe6xr6me4p Жыл бұрын
Great Video. 👍🏻👍🏻
@chintanconcept
@chintanconcept Жыл бұрын
Thanks for the visit
@jeetsingh-bg7fz
@jeetsingh-bg7fz 3 ай бұрын
NICE ATTEMPT
@janhavichavhan4131
@janhavichavhan4131 3 ай бұрын
Thank you sir it helps me
@chintanconcept
@chintanconcept 3 ай бұрын
Most welcome
@D_RahulKumar
@D_RahulKumar 9 ай бұрын
Sir NPSH required kaise leta hai manufacturer samjh nhi aya baaki puri video maine baar baar dekha yaad ho gya pura concept 👍
@chintanconcept
@chintanconcept 9 ай бұрын
Thanks !! NPSH r (Calculated by pump manufacturer) They continuously reducing the pressure of the resource tank and calculate NPSH, Once total dynamic head (H = hd -hs) reduces to 3%, That value to be considered as NPSH r
@ravitejapantla8022
@ravitejapantla8022 6 ай бұрын
👍
@vinayaksonawanexyz6555
@vinayaksonawanexyz6555 Жыл бұрын
Thanks sir.👍
@chintanconcept
@chintanconcept Жыл бұрын
Most welcome
@md.naeemulhasannaeem9870
@md.naeemulhasannaeem9870 3 ай бұрын
Thanks ❤
@chintanconcept
@chintanconcept 3 ай бұрын
You're welcome 😊
@imtiyaz95
@imtiyaz95 Жыл бұрын
👍👍👍
@AJ-et3vf
@AJ-et3vf 5 ай бұрын
Great video sir. Thank you!
@chintanconcept
@chintanconcept 5 ай бұрын
Glad it was helpful!
@akshaysinhmagodara8204
@akshaysinhmagodara8204 Жыл бұрын
👏👏
@Yashpatel-iq6hd
@Yashpatel-iq6hd Жыл бұрын
Nicee✨
@chintanconcept
@chintanconcept Жыл бұрын
Thanks 🔥
@the_francis.7
@the_francis.7 9 ай бұрын
Bro the direction of impeller vanes are wrong ...in this case water will churn inside the casing ... centrifugal force act nahi karega...baki explanation were to the point 🙌👌
@fajrulihsan1849
@fajrulihsan1849 8 ай бұрын
Full english please
@asnalishamsho2343
@asnalishamsho2343 10 ай бұрын
Very good explanation Sir. But i have a question, if put a pressure gauge on the suction side of the pump ( near the pump). Is it correct to say NPSHA is equal to pressure reading of the gauge minus vapor pressure of the liquid? Thank you again
@chintanconcept
@chintanconcept 10 ай бұрын
Yes that is NPSH, Exactly.
@asnalishamsho2343
@asnalishamsho2343 10 ай бұрын
@@chintanconcept thank you very much
@deobiloilchil
@deobiloilchil 6 ай бұрын
Do you have full English script? It woud be very beneficial
@chintanconcept
@chintanconcept 6 ай бұрын
not yet
@kartikeyasharma6769
@kartikeyasharma6769 4 ай бұрын
sir, pressure balance mai velocity head ka term kyu nhi aaya
@chintanconcept
@chintanconcept 4 ай бұрын
I really appreciate your question Velocity = flowrate/area Usually in static pressure head calculation & NPSH calculation we ignore the velocity head term which indirectly affects total energy(also constant flowrate) is there. Actually NPSH = (Ps-Pv)/p*g - V2/2g but doesn’t affect on total values.(hardly in 0.0…) Hope it is clear
@vijaykumarbiradar9537
@vijaykumarbiradar9537 Ай бұрын
1:19
@chintanconcept
@chintanconcept 27 күн бұрын
what ??
@pappalasunilkumar4805
@pappalasunilkumar4805 5 ай бұрын
Sir pressure=force/area then how will be pressure decreasing along with area.
@chintanconcept
@chintanconcept 5 ай бұрын
Hi It’s important to clarify that P= F/A represents how pressure is calculated, not how it changes within a fluid system. Here's how increasing pipe size can impact pressure within a fluid system: 1. Velocity: When you increase the size of a pipe while keeping the flow rate constant, the fluid velocity decreases. According to Bernoulli's principle, as the fluid velocity decreases, the pressure increases. So, in a larger pipe, the fluid exerts a higher pressure due to this reduction in velocity. 2. Volume: A larger pipe can hold more fluid volume, which might affect pressure if there are changes in flow rate or demand. However, the pressure exerted by the fluid itself is not directly related to the pipe size but rather to factors like fluid density, velocity, and external forces acting on the fluid.
@vinayakhuracan5182
@vinayakhuracan5182 22 күн бұрын
That is stagnation pressure
@msamirul1
@msamirul1 2 ай бұрын
You are confused between when to prssure increase or decrease w.r.t Area. As per bernaulli principles as area increase pressure will increase and vice versa
@nishantpatel640
@nishantpatel640 2 ай бұрын
kindly recheck 2.48
@chintanconcept
@chintanconcept 2 ай бұрын
Have you checked at 2.48 ???
UNO!
00:18
БРУНО
Рет қаралды 3,3 МЛН
ПРОВЕРИЛ АРБУЗЫ #shorts
00:34
Паша Осадчий
Рет қаралды 7 МЛН
I'm Excited To see If Kelly Can Meet This Challenge!
00:16
Mini Katana
Рет қаралды 30 МЛН
Пранк пошел не по плану…🥲
00:59
Саша Квашеная
Рет қаралды 7 МЛН
NPSH , Cavitation , Centrifugal pump in hindi || Chemical Pedia
13:38
Chemical Pedia
Рет қаралды 248 М.
Pumps - Net Positive Suction Head (NPSH)
25:58
Carl Wassgren
Рет қаралды 14 М.
Net Positive Suction Head NPSH
10:28
MECH 241 - Fluid Mechanics I
Рет қаралды 144 М.
Pump Chart Basics Explained - Pump curve HVACR
13:05
The Engineering Mindset
Рет қаралды 1,8 МЛН
How to Determine Available System NPSHA for a Pump
4:45
PSG, a Dover Company
Рет қаралды 26 М.
What is Pump Head? Application to Pump Design, Selection & Operation
21:30
Chemical Engineering Guy
Рет қаралды 623
pump calculations 3D
20:04
Terry Hagell
Рет қаралды 58 М.
UNO!
00:18
БРУНО
Рет қаралды 3,3 МЛН