सर जी आज तक ये बात युट्युबपर किसिने नहीं समझाई ,थँक्स सर
@nevish444 Жыл бұрын
भाई आपकी विडियो देख के संतुष्टि मिली ।बिल्कुल डिटेल से समझाया है❤
@sonumishra74553 жыл бұрын
Aapne bhut acchi tarh se samjhya esse pale you tube par aisi video nahi thi
@Iyengar54 Жыл бұрын
Excellent and very very useful details given by you. Thanks
@FaheemKhan-hu1se3 жыл бұрын
Acha...smjate hai.....good..bro...
@नरेशतोमर-च9ल3 жыл бұрын
सर डबल फेस मोटर को सिंगल फेस में रिवाइंडिंग करने का फार्मूला बताइए बहुत ही दिक्कत का सामना करना पड़ रहा है कोई बी वेंडर से पूछता हूं तो नहीं बताता है
@PerfectEngineer3 жыл бұрын
Kal
@bhumeshwardamahe32672 жыл бұрын
Sir osm best sir stator dekhke ciling fan Rewinding sikhaye
@tarunshakya83853 жыл бұрын
bahut acha video hai
@rathnamsmalathi6280Ай бұрын
Good Evening I need you suggest and your help. I want to know how to reduce the ceiling fan speed. I tried to use the regulater still the speed not much different. I want 70 Watts fan with low speed . So i need your support and suggestion.
@PerfectEngineerАй бұрын
Change the capacitor
@onestate77348 ай бұрын
Which fan stator is better 12 vs 18
@dholkarindustries58833 жыл бұрын
Nice video sir
@Subham_Love_From_Odisha_ Жыл бұрын
Sir RPM ka full form Revolution per minute he
@ankitnagora5161 Жыл бұрын
Kahan se padhaai ki Hai sir aapane Maine ITI aur diploma donon kiya hai aur RPM ki ful form hamesha round per minut hi padhaayaa gaya hai aapane kuchh naya Bata Diya
@ankitnagora5161 Жыл бұрын
Aur Delhi Pusa ITI aur Pusa diploma se
@shivak28527 ай бұрын
@@ankitnagora5161Rotations per minute is right answer! Revolution per minute it's for engines not for fans.
@govardhankumar7338 Жыл бұрын
RPM increase karne ka formula bhi bataye.....
@avtaarsingh52753 жыл бұрын
Sir 3 phase motor ch double delta or triple delta connection kasa karta na
@rupeshjoshi84402 жыл бұрын
Thank u nice video 👌
@mdsadrealam20863 жыл бұрын
Sir good vedeo
@SansarDehati5 ай бұрын
Nice
@sanjuzaam13573 жыл бұрын
Bahut sundar
@badshahkumar1014 Жыл бұрын
सर जी हाई स्पीड सेलिंग फैन 6+6=18 स्लॉट का डेटा बताइयेगा क्या होगा
@fahimashraf60523 жыл бұрын
Thanks sir
@natwarsharma2162 жыл бұрын
Meraj bhai 34 number elimuniyam wire se Pankha winding karen to kitne turn dalni chahie jisse pankhe ki speed sahi hai aur Garam Bhi Na Ho winding lacchi wali h
@rathnamsmalathi62802 жыл бұрын
Good Evening. Sir Iam very much impressed by your explanation . Pls can u help me ,iam looking for low speed celling fan RPM 230. Regards
@ashimhaldar28942 жыл бұрын
Nice
@biswajitsarkar2823 жыл бұрын
Good formulla bara vai
@vinodmahto88262 жыл бұрын
Thank you
@lokeshdadhich3643 жыл бұрын
Transformer winding Karne Ka Tarika batao na
@PerfectEngineer3 жыл бұрын
Iss par kaafi video bana rakhi hai
@lokeshdadhich3643 жыл бұрын
@@PerfectEngineer Transformer data kaise nikaalte hain
@ItsMeHaider2 жыл бұрын
brother stator material, core size, wire number, number of turns change karnay say bhi rpm par farq paray ga... 18 pole k stator par mein 50, turns ki winding kar dun ... lekin number of poles to 18 hi hein na is condition mein formula kaisay chalay ga...
@wasimakhtar93256 ай бұрын
राहुल पर मिनट आर्यन आरपीएम राउंड पर मिनट
@Mansoorali-vv2gq Жыл бұрын
Motor cut TV hay Uske Rota se RPM Kaise Maloom Karen 960 RPM motor Kitni salate hoti hain 14 40 RPM ka Rotor 28000 game ka Rota Kitni salate hoti hain motor cut TV hone ke bad Uske Rota se RPM Kaise Maloom Karen Rajasthan se Mansoor Ali winder
@keerthankumarplke86703 жыл бұрын
Sir Kannada people benefit🤗
@electronictechnical69163 жыл бұрын
Supar sir
@mohdmujahid84923 жыл бұрын
Sir welding machine coil ka data kaise calculated se nikaalte hai
@ItsMeHaider2 жыл бұрын
keya matlab 12+12 K RPM Sab say zeyada hotay hein .... us par winding bhi 18+18 say kam ho gi magnetic field kam generate ho gi to rpm zeyada kaisay??
@PerfectEngineer2 жыл бұрын
Jab number of pole kam hote hain to RPM jyada or pole jyada ti RPM kam hote hain
@ItsMeHaider2 жыл бұрын
@@PerfectEngineer to brother wohi pooch raha hun aisa q hai ...technical way mein jawab dein...
@PerfectEngineer2 жыл бұрын
Bro bataya to wahi tha but aapko simple bhaasha m samajh nahi aaya to technically samajh lo, RPM nikalne ka formula hota hai, N= F×120/P N= Syncronus Speed F= Frequency 120= Connection ki °( Digree) Yani 360°/3phase=120°ka kond bana P= Motor k Pol Isiliye Formula hai N= F×120/P N= 50×120/12=500 To 12+12 k RPM hue 500 Ye Syncronus Speed hai Ab Load pr RPM bachenge 500-5%=475 475 Motor k Standard RPM ( Speed) hai Bro isse jyada ab m nhi samjha sakta 🙏🙏🙏.
@ItsMeHaider2 жыл бұрын
@@PerfectEngineer ghussa hi kar gaye aap to brother..phir bhi wohi sawaal hai aap ghaur say nahi parh rahay.... aap technical way mein formula samjha rahay hein working nahi... mein yeh poochna chah raha hun k theek hai rpm 14 k sab say zeyada hon gey lekin phir hum 18 ka stator ya 21 ka stator q banatay hein 14 ka hi laga laitay hein winding bhi kam karni paray gi waqt bachay ga... rpm bhi zeyada milein gey... 36 ya 42 slot stator q banatay hein phir hum?
@ItsMeHaider2 жыл бұрын
subscribing..
@primewavez2 жыл бұрын
Dear friend Pole and coil is not same thing Example a motor in 12 coil but it Motor rpm 1440 So please tell me how it com Because it Motor 4 pole Each pole 3 coil set Don't confuse your viewer's
@PerfectEngineer2 жыл бұрын
Iska matlab science ke formule wrong hote hain 12 coil 3 phase ki motor m hote hain 12/3=4 pole Use formula N= F120/P ( N=50x220/4) = 1500 RPM 1500-4/5%= 1440 RPM Kahne ka matalab ye hai ki 12 coil ki 3 phase motor k ek circuit m 4 pole hote hain
@primewavez2 жыл бұрын
@@PerfectEngineer Let's we have an induction motor with p=2 and feed it from 50 Hz grid. Then we re-connect the winding coils to arrange p=4 and feed if grow 100 Hz grid. Are performances of these two motors different or the same? Please note excluding frequency and inter-coil connections all remained the same. It depends on the required speed. n (rpm) = (60 x f) / N where f = frequency and N = number of pole pairs. The 60 is there to convert from revolutions per second to revolutions per minute as the frequency is in cycles per second. Pole pairs is there because that any pole must be constructed in a pairs top and bottom / left right, so with one cycle it will move half the distance. If you are using 50Hz and have a two pole motor 60 x 50 / 1 = 3000 rpm. The induction motor will run at a slight less speed due to "slip" which is what gives the motor its torque. For example 5.5kW, 400v, 2 pole motor will run at approximately 2880 rpm. For a four pole machine, 60 x 50 / 2 = 1500 rpm so the same size motor at 5.5kW, 400v but 4 poles will have a nominal speed of 1500rpm but will run near 1455 rpm. 👉When selecting a three phase motor, the number of poles is chosen to achieve the speed of rotation that you require. Here are two tables, one for a 50 Hz power supply and one for a 60 Hz power supply: The formula is n = 60 x f /p where n = synchronous speed; f = supply frequency & p = pairs of poles per phase. The actual running speed is the synchronous speed minus the slip speed. For a 50 Hz three phase supply: 2 poles or 1 pair of poles = 3,000 RPM (minus the slip speed = about 2,750 RPM or 6 -7% n) 4 poles or 2 pairs of poles = 1,500 RPM 6 poles or 3 pairs of poles = 1,000 RPM 8 poles or 4 pairs of poles = 750 RPM 10 poles or 5 pairs of poles = 600 RPM 12 poles or 6 pairs of poles = 500 RPM 16 poles or 8 pairs of poles = 375 RPM For a 60 Hz three phase supply: 2 poles or 1 pair of poles = 3,600 RPM (minus the slip speed = about 2,750 RPM or 6 -7% n) 4 poles or 2 pairs of poles = 1,800 RPM 6 poles or 3 pairs of poles = 1,200 RPM 8 poles or 4 pairs of poles = 900 RPM 10 poles or 5 pairs of poles = 720 RPM 12 poles or 6 pairs of poles = 600 RPM 16 poles or 8 pairs of poles = 450 RPM To determine the number of poles, you can read the data plate directly or calculate it from the RPM stated on the data plate or you can count the coils and divide by 3 (poles per phase) or by 6 (pairs of poles per phase). Where the power of the induction motor is constant, the torque increases at the rate that the speed decreases 👉 I hope you understand