Might be there's a mistake in flowrate vs power in last point.....with increase in flowrate power decrease as somehow power increases
@ashok2265 Жыл бұрын
BEP(Best Efficiency Point)
@ChemicalMahi6 ай бұрын
Dear already shared video...
@nikhilsankhe38712 жыл бұрын
Good easy to understand👌👌
@chemicalengineer19852 жыл бұрын
Your pumps series is excellent
@ChemicalMahi6 ай бұрын
Dear Thanks...
@jayeshpatil44602 жыл бұрын
hello sir agar pump ke discharge side me nrv nahi rahato kay effects hoge sir
@gauravpatil9643 Жыл бұрын
Nice lecture
@ChemicalMahi Жыл бұрын
Keep watching
@anoopkumarpandey3483 жыл бұрын
Mast
@ChemicalMahi3 жыл бұрын
Dear Anoop Thanks...
@popsjourney71646 ай бұрын
Can you do the Speed vs Torque curve of a centrifugal pump
@ChemicalMahi6 ай бұрын
Dear sure soon....
@RahulPatil-vm8dl Жыл бұрын
Thank you so much
@ChemicalMahi6 ай бұрын
Dear Thanks...
@manjubalan4983 жыл бұрын
Sir can you please explaim pump hydraulics
@ChemicalMahi3 жыл бұрын
Dear Manju sure very soon....
@pranavsinhyadav1501 Жыл бұрын
Efficiency kya hoti he?
@ChemicalMahi Жыл бұрын
Dear Separate lecture is there on same topic...
@jayeshpatil44602 жыл бұрын
sir selection criteria pe bhi 1 lecture kariye sir like viscous liquid clear liquid solid semi solid
@krushnpalgohil29672 жыл бұрын
sir as increase in flow, efficiency also increase that's means perticular flow with good head but after maximum efficiency point we will increase flow there is decreased in head hence decrease in efficiency am i right?
@kunalpanchal23283 жыл бұрын
Hello sir, as explained in the earlier lectures that if the discharge valve is kept closed then there will be back pressure on impeller. So this back pressure will also lead to increase in power.
@ChemicalMahi3 жыл бұрын
Dear Kunal surely....
@kunalpanchal23283 жыл бұрын
@@ChemicalMahi but for flow rate vs power, it is said that initially there will be less power consumption when discharge valve is closed then what about back pressure here? And as soon as the discharge valve is opened the power required to run the impeller will increase. And also in case of throttling chapter it was explained that due to back pressure the power required will be more and in case of closed discharge valve the impeller may get damage also.
@ChemicalMahi3 жыл бұрын
Dear Kunal don't get confuse.Look at characteristic curve of Centrifugal pumps u can easily see that when u increase flow then power consumption increase and is minimum when valve is closed. For your second query Look at the power formula Power depends directly on flow rate and Inversely on Efficiency also by throttling the valve for a particular pump u are decreasing it's efficiency so power consumption increase than the case when it is fully open.
@syedzainAdil2 жыл бұрын
Sir ye baat abb bhi clear nhi hui efficieny ka kia matlb hai yani wo permanent hi kharrab ho jayega? Uski efficiency hi kamm ho jaye gi chahy hum uska discharge valve full open kardain? Sir ye point clear kardain plzz
@syedzainAdil2 жыл бұрын
Or agar hum valve throttle karty hain yani uska hum flowrate kamm karty hain ya hum discharge valve full closed karty hain to us surat main power consumption zyada kion nahi lag rahi jabky back pressure to is main bhi hai
@nikhilmene74424 жыл бұрын
Nice....Can you share lecture on head calculations
@ChemicalMahi4 жыл бұрын
Next to Next lecture will be on the same .........
@ChemicalMahi4 жыл бұрын
Dear,Eighth lecture was on head calculation approach and Ninth will discuss example for the same
@marutishinora38862 жыл бұрын
In lecture 4 you have said that Throttling of Valve will increas power consumption And here you are saying that Throttling of Valve will reduce power consumption as flow decrease by throttling Please reply
@souravkumar25224 жыл бұрын
How to calculate the power requirement (KW/hp) of motor for pump drive ??plz share it
@ChemicalMahi4 жыл бұрын
Dear Sourav Kindly see this lecture attached is link:-kzbin.info/www/bejne/mXWqdGmEpbKJorc
@syedzainAdil2 жыл бұрын
Sir area kamm karny sy pressure kamm hota hai or velocity increase hoti hai to jabb hum pipe ko aagy sy band karty hain garden main pani dety huye yani hum uska area kamm karty hain to kia velocity or pressure dono increase ho jaty hain???
@ChemicalMahi2 жыл бұрын
Dear Adil back pressure in hose increase as u close the outlet . Velocity will incraese.
@anoopmishra19353 жыл бұрын
Pls upload pdf link
@chandrasekharmohanta63343 жыл бұрын
Very confusing video
@ChemicalMahi3 жыл бұрын
What is confusing
@chandrasekharmohanta63343 жыл бұрын
@@ChemicalMahisir please repet this lecture 🙏
@ChemicalMahi3 жыл бұрын
Ok sure very soon. But u can tell me the query....
@chandrasekharmohanta63343 жыл бұрын
@@ChemicalMahi Sir SAIL OCTT trainee chemical posts preparation video please 🙏