Charging Best & Worst Practices

  Рет қаралды 4,143

HVAC School

HVAC School

Күн бұрын

Пікірлер: 7
@solankibharat8963
@solankibharat8963 Ай бұрын
Nice information knowledge hvac technician service time following good knowledge
@vincentgelles3805
@vincentgelles3805 Ай бұрын
I’ve been behind so many techs that have grossly overcharged a heat pump because of a restricted TXV in the cooling mode. If you dump enough gas in the system you can get it to stop freezing but it’s definitely not going to cool very well. Then when it comes time to run the heat the unit keeps going off on high pressure. I once removed over 8 pounds of refrigerant on a system that the factory charge was a little over 6 pounds! Before I ever get my refrigerant off the truck, I’m verifying airflow by checking all filters, the evaporator coil and blower wheel for cleanliness, and most importantly making sure the blower is working and if it’s a variable speed making sure it’s running at the correct speed. The scale always comes off the truck with the refrigerant every time. If I suspect I have an issue with the metering device, I will switch the reversing valve and look at the pressure in the other mode. This can help you determine whether it’s the metering device or possibly low on charge. I work on heat pumps primarily, I’d say about 99 percent of the systems I service and install are heat pumps.
@Respect.The.Grind..
@Respect.The.Grind.. Ай бұрын
It’s insane how many techs neglect to check filters. I was just on a job the other day that had a filter grill and a filter box at the air handler, both filters were still completely plugged up with sheet rock dust from new construction. Air flow was fucked coil was freezing up and they somehow managed to run a 1/4” liquid line instead of a 3/8s. lol wtf 😂
@marconantel7735
@marconantel7735 Ай бұрын
I’d like more information on the oil in the suction line and evaporators in general
@timothy5977
@timothy5977 Ай бұрын
Yeah I run into this all the time.
@marconantel7735
@marconantel7735 Ай бұрын
@ I saw someone saying you can decrease condenser air flow to boost head temperature and that ca help an oil logged evaporator…I was like..i wouldn’t know an oil logged evaporator if I had one…must to learn!
@heatingairservices8708
@heatingairservices8708 21 күн бұрын
we use throttled in or the quick charger adapter attached to suction manifold Gage set that sprays the liquid to gas before it enters suction port yes sir ......
HVAC Troubleshooting Part 1
1:10:37
HVAC School
Рет қаралды 17 М.
Vacuum Best Practices
29:25
HVAC School
Рет қаралды 6 М.
So Cute 🥰 who is better?
00:15
dednahype
Рет қаралды 19 МЛН
Quando A Diferença De Altura É Muito Grande 😲😂
00:12
Mari Maria
Рет қаралды 45 МЛН
HVAC Silver Soldering vs Brazing vs Brazing While Flowing Nitrogen!
18:42
AC Service Tech LLC
Рет қаралды 169 М.
How a Supermarket Refrigeration System Works
8:45
HVACR Career Connect NY
Рет қаралды 68 М.
Are more STAGES on an air conditioner worth it??
10:28
Atlas AC
Рет қаралды 381 М.
IAQ - Humidity and Moisture Control
1:03:03
HVAC School
Рет қаралды 5 М.
HVAC Troubleshooting Part 2
42:59
HVAC School
Рет қаралды 9 М.
Installation Best Practices: Brazing & Leak Checking
1:01:57
HVAC School
Рет қаралды 9 М.
Critical System Diagnosis for Residential HVAC
41:45
HVAC School
Рет қаралды 448 М.
So Cute 🥰 who is better?
00:15
dednahype
Рет қаралды 19 МЛН