Water Pressure Regulator Valve Rebuild

  Рет қаралды 27,220

CHARLES CRANFORD

CHARLES CRANFORD

Күн бұрын

Пікірлер: 43
@susiebernard6413
@susiebernard6413 3 ай бұрын
Thank you, thank you, thank you! My PRV is dripping. You probably just saved me a $350 plumber bill. God bless you, Charles.
@CHARLESCRANFORD
@CHARLESCRANFORD 3 ай бұрын
Thank you for your thanks.
@brandonniemi
@brandonniemi 6 ай бұрын
Nicely done, simple and straight forward!
@CHARLESCRANFORD
@CHARLESCRANFORD 6 ай бұрын
Thank you.
@rwillson11
@rwillson11 Жыл бұрын
You did a nice job on the video. Exactly what I needed to see. Thank you.
@CHARLESCRANFORD
@CHARLESCRANFORD Жыл бұрын
Thank you for your comment.
@ArcadeLightGrid
@ArcadeLightGrid 7 ай бұрын
Nice video, I replaced this valve and it was super easy thanks to all the info here.
@redhotgio
@redhotgio Жыл бұрын
Thanks for the video man . I really thought it was gonna cost me an arm and a leg but you save me some money.
@CHARLESCRANFORD
@CHARLESCRANFORD Жыл бұрын
Thank you for your comment. One of the reasons I fix stuff myself, is the cost savings. I am glad I could pass some knowledge on to you.
@kenstrike8699
@kenstrike8699 11 ай бұрын
Excellent video. Concise and clear. Thanks
@charlesfelix9955
@charlesfelix9955 7 ай бұрын
Nice how they run that power line right in your way
@CHARLESCRANFORD
@CHARLESCRANFORD 7 ай бұрын
Water right next to electricity. What could go wrong?
@tedhodgeske4nbb591
@tedhodgeske4nbb591 Жыл бұрын
Thanks for the video. I'm going to attempt the same repair today. I did notice an electrical line right next to your plumbing. I would suggest that circuit be switched off before doing any plumbing in that area.
@CHARLESCRANFORD
@CHARLESCRANFORD Жыл бұрын
Thank you for the safety tip. I would like to say that I did isolate that circuit ... but I did not. Lucky for me, the insulation on that wire was good. Good luck on your repair.
@vincemajestyk9497
@vincemajestyk9497 5 ай бұрын
Typical domestic water pressure is 45-50 PSI. You can set it to whatever you want but higher pressure just wastes water and puts more stress on your pipes and appliances. Maximum permitted by code is 75 and most municipalities will easily exceed that in off hours during idle periods in the early morning. If you're having a volume problem and everything else is fine that would point to the pipe size being inadequate. A lot of new homes are being built with 1" main supply piping. Typically, with a 20 psi falloff (when you open a faucet) you won't notice a difference between 55 psi and 75 psi. It's very small.
@thomascollins2966
@thomascollins2966 7 ай бұрын
A pressure reducing valve (PRV) is a variable friction loss device. To have friction loss the fluid needs flow. Unless the valve seats perfectly the downstream pressure is going to equalize to the upstream pressure. Once the downstream pressure is relieved (opening a valve) the PRV will open allowing the upstream pressure to compensate for the loss of downstream pressure to the spring set setpoint. The point is: to check the PRV setpoint a small flow is needed in the downstream. In most cases there is likely a dripping faucet or some other flow that will overcome the seat leakage but to be safe, crack a faucet open downstream to be sure the system is not hydraulically locked. Good video . Helped me prepare to do mine.
@CrazyFireTriangle
@CrazyFireTriangle 3 ай бұрын
Woooooo, I did It! Thanks Man
@CHARLESCRANFORD
@CHARLESCRANFORD 3 ай бұрын
Thank you for the thanks and congratulations on replacing yours yourself.
@rickjames6948
@rickjames6948 Жыл бұрын
PSI should be 30-60. WOW, you cross threaded the right inlet union on the PRV.
@srt4cuz
@srt4cuz Жыл бұрын
That's a big ass spider @ 1:25 😂 scared me
@CHARLESCRANFORD
@CHARLESCRANFORD Жыл бұрын
He was more scared of me than I was of him. You should check out the one that got in my canoe at about 3:28 on this video: kzbin.info/www/bejne/gGSZgKR3o6meeNU and spoiler alert: a fish almost ate him.
@jjfu2777
@jjfu2777 Жыл бұрын
Great video! but where to buy that rebuild kit?
@CHARLESCRANFORD
@CHARLESCRANFORD Жыл бұрын
Thank you for your comment. I should have mentioned that I got mine from an online company called zoro.com. I had bought something from them before, and they were the lowest cost of all the other companies that came up after searching, on the internet, for the same model that I had. Your pressure regulator valve should have some identifying markings on it that you could search and be able to find the kit for.
@DK-pr9ny
@DK-pr9ny 2 ай бұрын
@@CHARLESCRANFORDpart number?
@CHARLESCRANFORD
@CHARLESCRANFORD 2 ай бұрын
@@DK-pr9ny I didn't want to post a part number because there are so many different pressure regulators. I would suggest finding the number on your regulator and searching the internet to find the exact one to replace it with. Thank you for the question.
@ferra1702
@ferra1702 Жыл бұрын
thanks for making this video 👍
@CHARLESCRANFORD
@CHARLESCRANFORD Жыл бұрын
You are welcome. Thank you for your thanks.
@Big_Island_Boi
@Big_Island_Boi 4 ай бұрын
Couple of things. 1) Your water pressure doesn't need to be 75 psi. 60-ish is perfectly fine. 50-ish should suffice in most houses. And 2) You don't squeeze a bunch silicone all over the cartridge like that. That just makes a hot mess inside the valve that is going to get clogged with debris. The o-rings just have to to be coated with silicone... so, just a drop or so on them, rubbed all around, is just fine. Oh, and 3) that "special wrench" that would have made the job easier is just a Crescent wrench... nothing fancy or unique.
@ImListeningToReason
@ImListeningToReason 4 ай бұрын
Spot on 100%. PSI 55 fine for cold, and that SILICONE lubricant is to be used very sparingly. Sheesh. I would say this is a good video to see how to and not to do the work. Call it a first pass look as to what to expect on rebuild.
@majahanson311
@majahanson311 Жыл бұрын
Several months on, how has the repair held up? I just cleaned a bunch of that dirt/silt out of my PRV and while it did help at first, the problem seems to be creeping back. I wonder if it’s just an exercise I’ll need to repeat because either I didn’t flush enough out, or the source of the contamination is unresolved
@CHARLESCRANFORD
@CHARLESCRANFORD Жыл бұрын
My repair is holding up as good as new. I think a bunch of mud and grit got in the pipe when I replaced a leaking section of the main water supply line. I tried to keep everything clean, but it was in a muddy hole. I don't have any filter on my supply line, so that may be something that could help. I think the mineral content of your water could be a problem as well. My sister has well water and she gets a bunch of mineral build up in her hot water heater. So your "contamination" may just be natural occurring contents of the water. Good luck.
@Jason_Wheeler
@Jason_Wheeler 10 ай бұрын
pretty cool thanks I need to do a 1.25" rebuild or replace. I think ill rebuild looks easy.
@CHARLESCRANFORD
@CHARLESCRANFORD 10 ай бұрын
Thank you for your comment. It is easy.
@wtalber
@wtalber 9 күн бұрын
That is a horrible installation location! Almost would have been easier to remove the PRV. Mine is 30 years old, and reducing water flow. Thanks for the video!
@CHARLESCRANFORD
@CHARLESCRANFORD 9 күн бұрын
Thank you for your comment. At least mine was in a tall part of the crawlspace. I have messed with one before while laying on my back in the mud. Good luck getting your regulator valve fixed.
@wtalber
@wtalber 9 күн бұрын
@ Thanks! At least my crawlspace is dry, and the PRV is in the garage.
@davelosonczy1537
@davelosonczy1537 Жыл бұрын
👌👌
@ImListeningToReason
@ImListeningToReason 4 ай бұрын
Back it down to 45-50 psi. Do not set 'yours' that high. And a small application of the SILCONE lubricant is all that is needed. So this is a only good visual of what you can expect to do.
@gstrader73
@gstrader73 10 ай бұрын
In my experiences, it's easier just to replace the whole valve
@CHARLESCRANFORD
@CHARLESCRANFORD 10 ай бұрын
It could be easy, but rebuilding it was easy rebuilding it. Thank you for your comment.
@thomaswilliams1924
@thomaswilliams1924 7 ай бұрын
And way more expensive
@vincemajestyk9497
@vincemajestyk9497 5 ай бұрын
In the case of some of those cheap valves that may be so. In many cases like with the Conbraco/Apollo valves it's damn near impossible to get a kit. Almost like they WANT you to buy a new one. And their valves are $200-$300 depending on size for the 'cheapened' ones with the plastic top bell cap. For 3/4" and under you can get a replacement Watts or Zurn for under $100. The problem is breaking the connections to install it. If they're sweat joints or Propress'd PVC it's beyond most DIY'ers scope.
@rickjames6948
@rickjames6948 Жыл бұрын
Hope you and your family DON'T drink that water. OMG man.....
Replace a PRESSURE REDUCING VALVE That Sounds TERRIBLE
8:24
Handyman Hertz
Рет қаралды 41 М.
She wanted to set me up #shorts by Tsuriki Show
0:56
Tsuriki Show
Рет қаралды 8 МЛН
Жездуха 41-серия
36:26
Million Show
Рет қаралды 5 МЛН
Sigma girl VS Sigma Error girl 2  #shorts #sigma
0:27
Jin and Hattie
Рет қаралды 124 МЛН
Symptoms of a Leaky Pressure Reducing Valve & How to Replace it
17:08
Goetze Pressure reducing valve 681 | installation, function & maintenance
3:37
DMA Water Tech w/ Todd - Watts LF25AUB PRV
16:41
Disney-McLane & Associates
Рет қаралды 6 М.
Water Pressure Regulator Adjust or Replace | High Water Pressure In House
17:14
Home Inspection Authority
Рет қаралды 23 М.
Troubleshoot a Water Pressure Regulator
3:30
Know How Now
Рет қаралды 196 М.
How to replace a Water Pressure Regulator Valve
12:25
Fish OnReview
Рет қаралды 173 М.
30 Minute Secret Makes Your Water Heater Last Decades
13:03
LRN2DIY
Рет қаралды 2,4 МЛН
PLUMBERS HATE me for sharing their SECRET
5:34
seejanedrill
Рет қаралды 1,5 МЛН
She wanted to set me up #shorts by Tsuriki Show
0:56
Tsuriki Show