chiller കളിൽ Transducerന്റെ Working എങ്ങനെയാണ് | what is the Transducer | Function of Transducer

  Рет қаралды 7,232

HVAC Malayalam

HVAC Malayalam

Күн бұрын

In this video i am trying to explaining about different types of pressure Transducers using in HVAC systems. A pressure transducer is a device which converts an applied pressure into a electrical signal. mostly there are three transducers using in chillers 1) suction pressure transducer 2) discharge pressure transducer 3) oil pressure transducers . some of the chiller using economizer transducer also.
Dear Friends
I am Sreejith ,Welcome To HVAC Malayalam , I Have Been Working as a HVAC Technician Since 2005. In My Long carrier I Worked With Different Kind Of HVAC Systems. In This You Tube Channel I Would Like To Share or Explore My Experience and Thoughts.
This Channel Covers Both HVAC and Electrical Works To Help You Learn HVAC Service Engineering. I wish It Will Be More Useful and Experience To All. So Please Stay Tuned and Follow HVAC Malayalam For New Updates . Thank you
subscribe here👇
/ @hvacmalayalam
• എന്താണ് Liquid inject... what is the liquid injection
• എന്താണ് Economizer | E... Economizer function
• എന്താണ് Chiller | zami... All about air cooled screw chiller
• Part winding power con... part winding power connection
• Honey well thermostat ... Honeywell Thermostat wiring .setting. Testing
• എന്താണ് Ice skating ചി... ice skating chiller
• primary chilled water ... primary chilled water system
• Chiller Technician ആകണ... How to commissioning chiller
• Chiller Technician ആകണ... Chiller control wiring
• How To Use Clamp Meter... How To Use Clamp Meter
#transducer #hvac
#transducermalayalam
#pressuretransducer

Пікірлер: 54
@beanhabeeb506
@beanhabeeb506 2 жыл бұрын
thank you dear good information
@mansoorc171
@mansoorc171 3 жыл бұрын
വളരെ ഉപകാരപ്രദമായ വീഡിയോസ് 👍👍
@bijukumar12345
@bijukumar12345 7 ай бұрын
Chillar plant... temperature എങ്ങനെ set ചെയ്യുന്നത്, അതിൻ്റ ഒരു വീഡിയോ ചെയ്യാമോ ബ്രോ.very useful. .you got a long
@mphaneefakvr
@mphaneefakvr 3 жыл бұрын
വളരെ നല്ല പോസ്റ്റ് നന്ദി
@shibumohan3726
@shibumohan3726 3 жыл бұрын
Good video, and informative Expecting more videos..
@shibumohan3726
@shibumohan3726 3 жыл бұрын
May i get the WhatsApp number?
@renjuprakash9589
@renjuprakash9589 2 жыл бұрын
Sir, please make a detailed video about, types of compressors used in chiller.
@sajiths823
@sajiths823 2 жыл бұрын
Good information ....
@alexazhagar6222
@alexazhagar6222 2 ай бұрын
Super 👍👍👍
@arunnairappukuttan9735
@arunnairappukuttan9735 3 жыл бұрын
Very nice
@nejeebmullappalli7039
@nejeebmullappalli7039 2 жыл бұрын
very useful
@ajeeshperumpathayil3272
@ajeeshperumpathayil3272 3 жыл бұрын
Hats off you bro
@periyanayagammahadevan8586
@periyanayagammahadevan8586 2 жыл бұрын
Pls chiller control wiring for compressor terminal
@robinjacob8004
@robinjacob8004 3 жыл бұрын
Well explained 🙏🏼
@rageshcv4352
@rageshcv4352 2 жыл бұрын
Thanks
@sreekumarthampipillai4249
@sreekumarthampipillai4249 3 жыл бұрын
അപ്പോ hp lp switch nte function ithu ചെയ്യും അല്ലേ
@shabeeralfuttaim7665
@shabeeralfuttaim7665 3 жыл бұрын
Chillers candrool Wairing cheyamoo
@sadhana.j2701
@sadhana.j2701 3 жыл бұрын
Hello friends chiller chiller 30gt low cooler flow what's the reason think sensors so any more information please
@bibinpzy5873
@bibinpzy5873 2 жыл бұрын
ആശാനേ ഒരു chiller technician job uae ൽ enth salary പ്രതീക്ഷിക്കാം ഞാൻ ഒരു technician aan നിലവിൽ dubai ൽ job അന്നേഷിക്കുന്നൂ 6 years experience ഉണ്ട് HVAC field ൽ
@binuk5760
@binuk5760 2 жыл бұрын
Any jobs vacancies undel.. Onnu ariyikanme.. Bro..
@shajuahammu6988
@shajuahammu6988 3 жыл бұрын
Transducer enganeyanu check cheyinathu
@mohammedhaneefa6058
@mohammedhaneefa6058 3 жыл бұрын
Good
@shajuahammu6988
@shajuahammu6988 3 жыл бұрын
Transducer Enganayanu check cheyunathu
@manojkumarkarunkottath9838
@manojkumarkarunkottath9838 3 жыл бұрын
👍👍👍
@sureshkumar-fp8bl
@sureshkumar-fp8bl 3 жыл бұрын
MCS Magnum display യുടെ എല്ലാ Setting എങ്ങനെയാണ് ചെയ്യുന്നത് എന്ന് ഒരു വിഡിയോ ഇട്ടാൽ കൊള്ളമായിരുന്ന് . Password എങ്ങനെ open ചെയ്യാം .
@HVACMalayalam
@HVACMalayalam 3 жыл бұрын
Send me your Number
@sureshkumar-fp8bl
@sureshkumar-fp8bl 3 жыл бұрын
@@HVACMalayalam 00966550139518
@AboobackerKp-cn1tc
@AboobackerKp-cn1tc 3 ай бұрын
Can you help me
@tauheedraza9106
@tauheedraza9106 3 жыл бұрын
Sir compressor starting time there is liquid slugging in oil sight glass but after sometime it's normal oil showing so it's normal ??? Load is normal 30% load EEV 26% SP=32 DP=192 DT=180
@HVACMalayalam
@HVACMalayalam 3 жыл бұрын
Please check oil heater and liquid line solenoid valve. Oil heater must be on while compressor off position. And make sure while cut of the compressor must be pump down and off the compressor
@tauheedraza9106
@tauheedraza9106 3 жыл бұрын
@@HVACMalayalam liquid line is not normal hot but hot and all rest is normal
@tauheedraza9106
@tauheedraza9106 3 жыл бұрын
When compressor is running with 60% load that time liquid line is normal hot
@john-db8vq
@john-db8vq 3 жыл бұрын
👍
@niyavlogs9198
@niyavlogs9198 3 жыл бұрын
carrier chiller alarm T114. i changed suction tranducer, and suction temperature sensor,but same complaint happen. what is the problem.i checked error code book.complaint is low suction super heat. what is the solution .please give reply
@HVACMalayalam
@HVACMalayalam 3 жыл бұрын
What is the actual superheat? . check manually . Maybe expansion valve malfunctioning,refrigerant over charge, chilled water flow problem These Things you have to check .
@niyavlogs9198
@niyavlogs9198 3 жыл бұрын
cir A Cir A1 Cir B Cir B2 tandem scroll compressor.cir B B2 condition ok. problem is Cir A and A1.10 minutes running after alarm displaying T 114. Refrigerant R 410. suction 120 discharge 450. electronic expansion valve. I check the book let. T.114 means low suction super heat. i change suction tranducer and suction temperature sensor. but after 10 to 20 minutes same alaram .please give reply.
@HVACMalayalam
@HVACMalayalam 3 жыл бұрын
Bro Low superheat reason is suction temperature sensor, suction transducer, refrigerant overcharge, expansion valve open stuck , low evaporator water flow .check these basic Things .Then again problem let me know. Please send me chiller full model number also.
@niyavlogs9198
@niyavlogs9198 3 жыл бұрын
ok bro. tomorrow i will change electronic expansion valve. thanks bro for your information.
@niyavlogs9198
@niyavlogs9198 3 жыл бұрын
hello bro. carrier aqua snap chiller T114 alaram.yesterday i discussed with this matter.I changed suction tranducer, suction temperature thermister, expansion valve board, but same complaint is happen. circuit B compressor working ok. Problem is circuit A . when unit starting superheat is 50, then slowly going down and become zero, then trip the unit. some time superheat going to 80 to 90 then tripping the A1 circuit. i dont know what is the complaint. please help
@thestudio4583
@thestudio4583 2 жыл бұрын
not transuser it's TRANSDUCER
@jimonantony2535
@jimonantony2535 3 жыл бұрын
Sreejith sir contact number plss
@sreekumarthampipillai4249
@sreekumarthampipillai4249 3 жыл бұрын
thanks
@binsonbabu2676
@binsonbabu2676 3 жыл бұрын
👍👍
Зу-зу Күлпаш 2. Бригадир.
43:03
ASTANATV Movie
Рет қаралды 708 М.
Стойкость Фёдора поразила всех!
00:58
МИНУС БАЛЛ
Рет қаралды 7 МЛН
Superheat & Subcooling | HVAC|Tamil |Lohisya media| Ravishankar
13:00
Зу-зу Күлпаш 2. Бригадир.
43:03
ASTANATV Movie
Рет қаралды 708 М.