Why when I use negative starting station like chanaige - 2+883.8, property validation error appear and saying enter a positove value
@JeewC3D3 жыл бұрын
Your aligmnent should have negative stations to do that. If your aligment begins at 0+000 you cant do that.
@francispadriga28553 жыл бұрын
Yes sir@@JeewC3D my alignement start at negative chainage - 2+888 up to 20+500, the problem is not working when i use chainage - 2+883 as my starting station and - 2+803 as my end station. What do you think sir point by measure alignment is not applicable for negative chainage/station? How to add different interval,
@JeewC3D3 жыл бұрын
This issue is version related. It works with 2022. But has problems with 2020. What version you are using.
@francispadriga28553 жыл бұрын
@@JeewC3D ahh okay sir, Im using 2019 and 2020 version, is there any technique how to put points on my alignment from different distances sir
@JeewC3D3 жыл бұрын
2020.6 update works fine. I posted this issue in Civil 3D forum. This is the answer I got. But 2020 has problems however.
@md-mohammed84553 жыл бұрын
Sir , how I can draw point on surface at pre define offset , both side of alignment . Pre deinfed offset is : 0,-5,-10,-15,-20 and 5,10,15,20 etc. Please explain After that I want export that point in Excel with station offset elevation format. Please explain Thanks
@JeewC3D3 жыл бұрын
Do as in the video with having values 5,10 etc for offset intead 0. Use none for elevation option. After create point select the points then right click elevation from surface.
@JeewC3D3 жыл бұрын
Then use this video to export points. kzbin.info/www/bejne/Z6O7enR6m8qSpLM.