Bending Moment in Footing | Footing Design | Design of footing | Maximum bending moment in footing

  Рет қаралды 21,587

Civil Engineering Mastery

Civil Engineering Mastery

Күн бұрын

Пікірлер: 41
@CivilEngineeringMastery
@CivilEngineeringMastery Жыл бұрын
The size of the footing is 2.56 x 2.56m and qu is 343.32 kN/m2. Kindly ignore the calculation error.
@RevathiSureshKumar-p8t
@RevathiSureshKumar-p8t Ай бұрын
Nice explanation
@HeenaDabasia
@HeenaDabasia Жыл бұрын
Very Well explained Madam 👏 However I have a question on the Bending moment, A column passes down the axial load on to the foundation from which we calculate the Bending moment on the foundation which in your example it comes to 585 KNm, If the column had an axial load together with a Bending Moment say 'M' do we add this bending moment to 585 KNm and then design the Pad foundation with 585 KNm + 'M' to get the total bending moment on the footing? Or should we ignore the M?
@rahmanrahmani2896
@rahmanrahmani2896 4 жыл бұрын
Excellent work as always. Could you write all the formulas that you are using for the calcs. You need min reinforcement at the top in both directions as well. Could please do one combined footings with eccentric loadings. Thank you
@brianmugabi7516
@brianmugabi7516 4 жыл бұрын
Minimum reinforcement may not be necessary especially if the ultimate moment is greater than the design moment. Otherwise, it is necessary.
@rajendrajhoorawat95
@rajendrajhoorawat95 4 жыл бұрын
Excellent mam
@shunmugaraja.k.beatsofhear6775
@shunmugaraja.k.beatsofhear6775 4 жыл бұрын
Thanks for giving your Knowledge. Please post raft footing for reduce the steel alternative to mat footing.
@brianmugabi7516
@brianmugabi7516 4 жыл бұрын
Well explained especially how the bending moment comes about and why reinforcement steel is provided at the bottom.
@CivilEngineeringMastery
@CivilEngineeringMastery 4 жыл бұрын
Thank you!
@sachinmankal4545
@sachinmankal4545 4 жыл бұрын
Please make video on DESIGN OF DOUBLE ECCENTRIC OR CORNER FOOTING
@KishoreKumar-nr3vv
@KishoreKumar-nr3vv 4 жыл бұрын
Very nicely explained, Thank you very much once again. Regards
@KishoreKumar-nr3vv
@KishoreKumar-nr3vv 4 жыл бұрын
You're the best Mam
@BG-tp1xo
@BG-tp1xo 4 жыл бұрын
Thanks for sharing valuable knoweledge
@CivilEngineeringMastery
@CivilEngineeringMastery 4 жыл бұрын
Glad it was helpful!
@dennythomasmulavana8694
@dennythomasmulavana8694 4 жыл бұрын
Great
@ghiovanidayanan2716
@ghiovanidayanan2716 2 жыл бұрын
Hello, I would like to ask how do you prepare your presentation, just like that hand writing. How did you do that? thanks
@frsaj7396
@frsaj7396 4 жыл бұрын
please make video about shear wall design
@praveenkumar-tz3in
@praveenkumar-tz3in 4 жыл бұрын
Nic👍
@narasimhamurthy2800
@narasimhamurthy2800 4 жыл бұрын
Mam also post how to find the depth of a footing and depth of beam
@narendrarbhagyaa1012
@narendrarbhagyaa1012 3 жыл бұрын
Mam well explained thank you
@INDIAmeansBHARAT1950
@INDIAmeansBHARAT1950 Жыл бұрын
Can we find bearing capacity of soil
@ajinleo614
@ajinleo614 3 жыл бұрын
Tk u
@hanumanthprabhu8120
@hanumanthprabhu8120 3 жыл бұрын
Mam where to provide double mat in footing and why? Please explain.thank you.
@solaimanhossain2097
@solaimanhossain2097 3 жыл бұрын
Hi madam i like your lecture
@CivilEngineeringMastery
@CivilEngineeringMastery 3 жыл бұрын
Thank you! 🙂
@sudarshannikam5243
@sudarshannikam5243 Жыл бұрын
Mam u have calculated Ast for whole section 2650 x 667 mm, But u calculated bar spacing for 1000 mm strip. So at 9:42, There should have 2650mm instead of 1000mm. Actual spacing will be 297 mm for 20 mm dia bar.
@rakeshtanwar7283
@rakeshtanwar7283 9 ай бұрын
When you are calculate the size of flooting Area = 6.6 m^2 , side = squre root 6.6 = 2.56 by you can take 2.6 Bymistake you take 2.65 instead of 2.56
@CivilEngineeringMastery
@CivilEngineeringMastery 9 ай бұрын
Thank you for the notification. The size of the footing is 2.56 x 2.56m and qu is 343.32 kN/m2. Kindly ignore the calculation error. This information was pinned in the comment box.
@hs.markandeyahonnalisiddap5534
@hs.markandeyahonnalisiddap5534 Жыл бұрын
No of barsequals totalastdividedbysmallast
@jawaharbharani1866
@jawaharbharani1866 4 жыл бұрын
How the net soil pressure can be greater than SBC?
@CivilEngineeringMastery
@CivilEngineeringMastery 4 жыл бұрын
Net soil pressure is calculated at ultimate load. Factor of safety - 1.5
@jawaharbharani1866
@jawaharbharani1866 4 жыл бұрын
Can the soil resist more pressure than SBC,how?pls explain.
@CivilEngineeringMastery
@CivilEngineeringMastery 4 жыл бұрын
No need to compare Net soil pressure at ultimate load with SBC. Actual soil pressure should not exceed SBC. Actual soil pressure q = (load/area)+Self weight of footing + Self weight of soil. Please refer the below link for more clarification kzbin.info/www/bejne/nJzOZ62dbcaDhbc kzbin.info/www/bejne/kGfJf6COnLx0rdU
@kapishsharma1018
@kapishsharma1018 4 жыл бұрын
@ 5:10 in area of footing calculation why you have multiply 1500 with 1.1 and from where it came
@CivilEngineeringMastery
@CivilEngineeringMastery 4 жыл бұрын
1.1 is 10% of back fill load. (1500X1.1) is the total load or 1500+((1500X10)/100).
@narasimhamurthy2800
@narasimhamurthy2800 4 жыл бұрын
Mam I think the area of footing will be 2.56*2.56 then the area will be nearly 6.6m2 please check once.
@CivilEngineeringMastery
@CivilEngineeringMastery 4 жыл бұрын
Yes, you are correct.There was a error.Thank you for the notification.
@rajeshkumarlohana
@rajeshkumarlohana Жыл бұрын
Bending moment is not calculated properly,
@MKapitan
@MKapitan Жыл бұрын
Double check the calculations tho Just two major errors within a few seconds Footing sides = SQRT(6.6) is NOT 2.65 qu is not 320.4 I think she fell on the calculator or something....
@CivilEngineeringMastery
@CivilEngineeringMastery Жыл бұрын
Kindly ignore the calculation error. look into the concept.
Design of Isolated Square Footing | ACI 318
16:06
Engineeringly
Рет қаралды 8 М.
Perfect Pitch Challenge? Easy! 🎤😎| Free Fire Official
00:13
Garena Free Fire Global
Рет қаралды 72 МЛН
The IMPOSSIBLE Puzzle..
00:55
Stokes Twins
Рет қаралды 68 МЛН
Mia Boyka х Карен Акопян | ЧТО БЫЛО ДАЛЬШЕ?
1:21:14
Что было дальше?
Рет қаралды 11 МЛН
Pad Foundation Design Part 1.
6:33
Structural Engineer Calcs
Рет қаралды 42 М.
Design of column footing
13:44
Civil Engineers
Рет қаралды 834 М.
How to Design Pad Footings under Eccentric Loading (N and M)? Design of reinforced concrete footings
22:12
The Efficient Civil Engineer (by Dr. S. El-Gamal)
Рет қаралды 40 М.
ECCENTRIC FOOTING DESIGN (COLUMN IS AT EDGE OF THE FOOTING)
8:27
Perfect Pitch Challenge? Easy! 🎤😎| Free Fire Official
00:13
Garena Free Fire Global
Рет қаралды 72 МЛН