The size of the footing is 2.56 x 2.56m and qu is 343.32 kN/m2. Kindly ignore the calculation error.
@RevathiSureshKumar-p8tАй бұрын
Nice explanation
@HeenaDabasia Жыл бұрын
Very Well explained Madam 👏 However I have a question on the Bending moment, A column passes down the axial load on to the foundation from which we calculate the Bending moment on the foundation which in your example it comes to 585 KNm, If the column had an axial load together with a Bending Moment say 'M' do we add this bending moment to 585 KNm and then design the Pad foundation with 585 KNm + 'M' to get the total bending moment on the footing? Or should we ignore the M?
@rahmanrahmani28964 жыл бұрын
Excellent work as always. Could you write all the formulas that you are using for the calcs. You need min reinforcement at the top in both directions as well. Could please do one combined footings with eccentric loadings. Thank you
@brianmugabi75164 жыл бұрын
Minimum reinforcement may not be necessary especially if the ultimate moment is greater than the design moment. Otherwise, it is necessary.
@rajendrajhoorawat954 жыл бұрын
Excellent mam
@shunmugaraja.k.beatsofhear67754 жыл бұрын
Thanks for giving your Knowledge. Please post raft footing for reduce the steel alternative to mat footing.
@brianmugabi75164 жыл бұрын
Well explained especially how the bending moment comes about and why reinforcement steel is provided at the bottom.
@CivilEngineeringMastery4 жыл бұрын
Thank you!
@sachinmankal45454 жыл бұрын
Please make video on DESIGN OF DOUBLE ECCENTRIC OR CORNER FOOTING
@KishoreKumar-nr3vv4 жыл бұрын
Very nicely explained, Thank you very much once again. Regards
@KishoreKumar-nr3vv4 жыл бұрын
You're the best Mam
@BG-tp1xo4 жыл бұрын
Thanks for sharing valuable knoweledge
@CivilEngineeringMastery4 жыл бұрын
Glad it was helpful!
@dennythomasmulavana86944 жыл бұрын
Great
@ghiovanidayanan27162 жыл бұрын
Hello, I would like to ask how do you prepare your presentation, just like that hand writing. How did you do that? thanks
@frsaj73964 жыл бұрын
please make video about shear wall design
@praveenkumar-tz3in4 жыл бұрын
Nic👍
@narasimhamurthy28004 жыл бұрын
Mam also post how to find the depth of a footing and depth of beam
@narendrarbhagyaa10123 жыл бұрын
Mam well explained thank you
@INDIAmeansBHARAT1950 Жыл бұрын
Can we find bearing capacity of soil
@ajinleo6143 жыл бұрын
Tk u
@hanumanthprabhu81203 жыл бұрын
Mam where to provide double mat in footing and why? Please explain.thank you.
@solaimanhossain20973 жыл бұрын
Hi madam i like your lecture
@CivilEngineeringMastery3 жыл бұрын
Thank you! 🙂
@sudarshannikam5243 Жыл бұрын
Mam u have calculated Ast for whole section 2650 x 667 mm, But u calculated bar spacing for 1000 mm strip. So at 9:42, There should have 2650mm instead of 1000mm. Actual spacing will be 297 mm for 20 mm dia bar.
@rakeshtanwar72839 ай бұрын
When you are calculate the size of flooting Area = 6.6 m^2 , side = squre root 6.6 = 2.56 by you can take 2.6 Bymistake you take 2.65 instead of 2.56
@CivilEngineeringMastery9 ай бұрын
Thank you for the notification. The size of the footing is 2.56 x 2.56m and qu is 343.32 kN/m2. Kindly ignore the calculation error. This information was pinned in the comment box.
@hs.markandeyahonnalisiddap5534 Жыл бұрын
No of barsequals totalastdividedbysmallast
@jawaharbharani18664 жыл бұрын
How the net soil pressure can be greater than SBC?
@CivilEngineeringMastery4 жыл бұрын
Net soil pressure is calculated at ultimate load. Factor of safety - 1.5
@jawaharbharani18664 жыл бұрын
Can the soil resist more pressure than SBC,how?pls explain.
@CivilEngineeringMastery4 жыл бұрын
No need to compare Net soil pressure at ultimate load with SBC. Actual soil pressure should not exceed SBC. Actual soil pressure q = (load/area)+Self weight of footing + Self weight of soil. Please refer the below link for more clarification kzbin.info/www/bejne/nJzOZ62dbcaDhbc kzbin.info/www/bejne/kGfJf6COnLx0rdU
@kapishsharma10184 жыл бұрын
@ 5:10 in area of footing calculation why you have multiply 1500 with 1.1 and from where it came
@CivilEngineeringMastery4 жыл бұрын
1.1 is 10% of back fill load. (1500X1.1) is the total load or 1500+((1500X10)/100).
@narasimhamurthy28004 жыл бұрын
Mam I think the area of footing will be 2.56*2.56 then the area will be nearly 6.6m2 please check once.
@CivilEngineeringMastery4 жыл бұрын
Yes, you are correct.There was a error.Thank you for the notification.
@rajeshkumarlohana Жыл бұрын
Bending moment is not calculated properly,
@MKapitan Жыл бұрын
Double check the calculations tho Just two major errors within a few seconds Footing sides = SQRT(6.6) is NOT 2.65 qu is not 320.4 I think she fell on the calculator or something....
@CivilEngineeringMastery Жыл бұрын
Kindly ignore the calculation error. look into the concept.