Box-Girder Construction Full video kzbin.info/www/bejne/eYSre36nabNphLc
@chandrashekhar39292 жыл бұрын
Explained very nicely. Slump test is done to test water cement ratio which has direct impact on the design strength of concrete. The reduction in height after the cone is removed depends on the type of concrete vis a vis design strength. For example concrete of M20, M25, M30 etc have different reductions in height after the cone is removed.
@Whistleblowerz Жыл бұрын
Amazing video sir, most knowledgeable I can guarantee. Thank you so much. Keep providing us such valuable content. Thank you sir.
@QualityEngineer8193 жыл бұрын
Very nice sir prectical video dekh kr bhut kuch sekhne ko mila Again Thank you so much🙏
@AmoghC3 жыл бұрын
For slump test, number of layers is 3 and for each layer the tamping should be 25 times. Care should be taken that while tamping 2nd layer it must not penetrate 1st layer and same for 3rd layer, this test should be completed within 2 min, Ref: IS 1199(part-2):2018 (but your video is informative, keeping growing good luck)
@chandramohanpai20823 жыл бұрын
Test taken to make a video l don't think in india any bulider will waste time in such tests concrete comes pour it work done go home that is regular practise time pass video
@muqeemkhan88603 жыл бұрын
Now the standard has been change. You must penetrate the previous layer by 1 inch. The way he test the slump is bulshit. Slump must be fill in 3 layer. 1st layer 7 cm. 2nd layer 16 cm. 3rd layer 30 cm. Tamping in each layer must be 25 time.
@rashidhussain6182 Жыл бұрын
I agree with you
@shakirraza32553 жыл бұрын
Tremendous job you are doing sir .... Keep it sir
@vijaybhojane84602 жыл бұрын
MASS Scientific Sales Mr. Mahipat is very good work
@ayushjain42493 жыл бұрын
As per IS code 1199 2018.......We fill the slump cone in 3 layer of 25 time stroke each...The hole procedure should be done within the 3 min time frame
@princetomar63633 жыл бұрын
Right
@atoullshukkla56253 жыл бұрын
I also noticed same he said 4 layer 25-28 tamping Totally wrong. And again said 35 tamping in cube filling, he doesn't know any thing
@princetomar63633 жыл бұрын
@@atoullshukkla5625 25 time is right
@princetomar63633 жыл бұрын
I can proof
@errishavsingh37672 жыл бұрын
At 21:32 jo 22.5 hai wo metre me hona chahiye kyuki 150mm*150mm=22500mm ata hai aur isko metre me convert karne pe ye 22.5metre ho jata hai.....aur 600kilo N hai ya only Newtown? Bhai mujhe kuch jagah calculation explaining me error laga hai...
@rupeshgavand4449 Жыл бұрын
If you want to know Top 3 equipment to start Concrete Testing Lab click here kzbin.info/www/bejne/Z6q1naNmbamMnKM
@krunalbrahmbhatt67753 жыл бұрын
Thank you brothet for giving practical information👍🏻🤝🏻🙂
@sagarprakashkudekar68523 жыл бұрын
Apka jo KN/Nmm2 ka volume ata hai usko grade of concrete se divided karo usse pata chalega ki kitna % hai
@sanjaykamble85372 жыл бұрын
........
@karansahni68432 жыл бұрын
adhoora gyan nhi please, KN/mm² ka volume? ye kya cheez hoti hai yrrr
@karansahni68432 жыл бұрын
value likho typing error mtt kro boht freshers isi me confuse ho jayenge
@girishkumarpradhanpradhan79193 жыл бұрын
best valuable civil engg site technical knowledge
@IndianHeart072 жыл бұрын
22:25 Actually 7 days me 67% strength and 14 days days मे 87% strength achieved होनी चाहिए according with IS code 🙏
@udaisingh25492 жыл бұрын
Which IS code
@udaisingh25492 жыл бұрын
Apne konse IS code me dekha
@bikashsahoo9993 жыл бұрын
Jaldi se jaldi 1 million hoga
@AmitThakur-nk8zz3 жыл бұрын
Very nice u r sharing greatful knowledge
@BQCCB233 жыл бұрын
Practical dekh kar confidence bad gya sir
@khansirfunnyvideo36173 жыл бұрын
Aa a
@halalmeatshophk3 жыл бұрын
did you made a mistake in the estimate of 28days strength? you wrote 30 * 28 / 100 , whereas it should be 30 * 99 / 100, am i right ?
@yogeshgoyal51333 жыл бұрын
Correct bole, Yhi me bolne vala tha
@simpledaud27783 жыл бұрын
22.5 kaise liya sir ne?
@princetomar63633 жыл бұрын
kzbin.info/www/bejne/qXuak6OVm6aKbZY
@paporidas46423 жыл бұрын
please clear this doubt civil site visit. i have this doubt too.
@bobbleheadxtreme38013 жыл бұрын
Strength = load/ area of mould = load/22.5
@amaze-o-tronics45762 жыл бұрын
Very nicely carried out practical concrete various tests and explained to understand even dull student. Best video
@pilotgaming8739 Жыл бұрын
F uk v
@ertauseef23 жыл бұрын
Bhut hi badia video h Sir G.👍
@anilkumarsharma89013 жыл бұрын
Engineering👨🔧 key bahut video🎥 hain 😇😇😇 Apni bhasha ki baat hee kuch aur hain😇😇😇😇😇
@SurajKumar-oc3he3 жыл бұрын
Sir bahot maaza aa raha h aap ka video dekh kr k
@renushailsunnass68082 жыл бұрын
The slump test is considered failed as per bs when the concrete collapse. The concrete is too watery. Desired values are between 40 and 80 unless it's a pump mix with extra cement. The method for raising the cone is inappropriate, he should lift the cone from a higher or standing position. Anyway good initiative to show test on site. Kudos
7 din ke liye apne 65 se multiply karbaya or 28 din ke liye direct 28 se ye kya baat Hui engineer sahab
@syedmohtashimali74343 жыл бұрын
Hello Assalamualaikum good to see this video love it ...
@matukanpandey53102 жыл бұрын
1 sample pe 3 specimen ready kiya jaata h na..???
@the_real_adarsh90823 жыл бұрын
jittaa 4 saal me nhi pdhaaa uttnnaa 40 min me btaadiyaa sir aapne or site construction vaale ques. laauyee sir ap 🤗🤗🤗🤗
@civilsitevisit3 жыл бұрын
🖤
@hansrajparmar95003 жыл бұрын
Vah sir Love you from devbhumi dwarka ❤
@princetomar63633 жыл бұрын
kzbin.info/www/bejne/qXuak6OVm6aKbZY
@bijaynayak73253 жыл бұрын
Hyy
@thesunil9204 ай бұрын
Very helpful video sir..❤
@tangshukraireang67893 жыл бұрын
how did you get area of cube as 22.5 ? if you divide 600 with 22.5 how comes your strength of concrete in kn/mm2. please rectify your mistakes bro.
@narwaladvanture2 жыл бұрын
150x150
@narwaladvanture2 жыл бұрын
150x150
@AN-kk4in2 жыл бұрын
(15*15)/10
@sanjayrathod5380 Жыл бұрын
150x150 = 225 ..... Y 22.5 ????
@tausifmta7862 жыл бұрын
Thnkuu for giving knowledge concrete testing
@natvarsinhzala31223 жыл бұрын
Thankyu so much sir ji👏👌👌Mene to apke ye test ke video pahle dekhe the aek aek krke lekin aaj fir se revision ho gaya sirjii superb plz sir or video banao jisse hame pura knowledge mil ske 🥰🥰👌👌👌🌷🌷🌷
@devrajsinghmarwadi46793 жыл бұрын
1 sariya Fitter+ 1 helper = _____ Kg. 1 Carpenter+ 1 Helper= ______ sqm. 8 ghante Ki Job me. Kitna Productivity Hota he practically.
@parvejalam72843 жыл бұрын
Very helpful Video for freshers sir thanks for making this.....these three test are very very important for civil engineer bring some more videos 👍
@abhinavgupta61992 жыл бұрын
Cement ke grade par bhi nirbhar karta hai na sir
@YOUR.TRADER2 ай бұрын
Good TEACHER ❤🎉🎉❤🎉❤
@ankit46253 жыл бұрын
Great effort sir... 🙏🙏
@asifnakwa1353 жыл бұрын
ASTM standard as per 3 layer not 4 layer flings slump cone also lifting slump cone within 5-+2 second asper ASTM
@logiclessmind15253 жыл бұрын
Cube should be filled in 3 layers and slump cone should be filled in 4 layers
@shaikhfayaz86962 жыл бұрын
@@logiclessmind1525 please let me know standard?
@faizan_e_syedzabeebshahsah28583 жыл бұрын
Thanks For The Awesome Content Appreciate From Pakistan
@xlr8killerr7043 жыл бұрын
🙏 aapka bohot aabhar🙏🙏🙏
@abushahma7787 Жыл бұрын
amazing video...very interesting
@ranapratapdatta3703 жыл бұрын
Pillars are already constructed upto base level.but sudden shortage of money had kept the construction work on suspension for five months. Do u think it will damage the bar that are open from the pillars
@chandrashekhar39292 жыл бұрын
Cement wash the exposed rebars including stirrups to prevent formation of rust. Rust is very dangerous as there won't be proper bondage with the concrete if the rebars have become rusty.
@rameshangala35652 жыл бұрын
Chemical coat for rods will be added advantage
@microflyer2020 Жыл бұрын
sir mere yaha Thekedar n mistri k sath mil k dhokha de diya...... double shift m kam kara rh th night 8 Baje ka bana masala jo ki pilar casting m use hona th usko next day 11 am k aas pas extra cement mila kar Pilar casting kr diya...... y masala 2 pilar m use kiya gy th 4 ya 5 feet ka pilar cast kiya th... jo ki plinth beam k niche use hua th... plinth beam Ground level s 7 feet upar h jisme soil filling ki gyi h.... aaj building 3 floor ki h... ky hm log safe h???? area 1200sq mtr 14 column h jo ki 9*12 size k h.. 4 tmt bar 16mm k & 2 bar 12 mm k h in each column.. plinth n niche brick work only outer beam k niche kiya gy all four side baki andar soil filling h only... plz help
@ravishnirman2 жыл бұрын
As per BSEN or ASTM for the slump testbitz only 3 layers...BSEN its says equal hight of layers,ASTM its says equal quantity for layers
@msrajput70963 жыл бұрын
Sir agr humne 10 M3 ka concrete site pe mngaya h to jo gddi usko leke ayegi hume kaise pta chlega k usme purra 10m3 maal aya h plz tell?
@dm96366150392 жыл бұрын
Sir 0 to 5 m3 quantity ka mtlb kya hai. Ek bar jo concrete ban rha hai vo ya din bhar me jo bn rha hai vo ya total work me concrete bnega vo
@asgarali30462 жыл бұрын
Bhai RMC m 7 m^3 se jyada concrete nhi aata so jitna quantity v RMC m aata h site p usi ko measure Krna hota h or uska report v banana padta h
@SantoshSingh-fj8fs2 жыл бұрын
Sir failure hone pr ...baad me uska solutions kaise kare ..uss pr bhi video banaye🙏🙏
@Raushankumar-kw8bo3 жыл бұрын
Please upload this type of more videos
@DEVILGAMER-tb5ie3 жыл бұрын
I am a civil engineering student from Government polytechnic mujhana hata kushinagar
@naveenagarwal76652 жыл бұрын
bahut achha sir. Aap hmare office Aimil Ltd ki digital machine use kijiye achha result milega .
@pritiranjanjena89853 жыл бұрын
Sir sirf cone ka hight 300mm he aap jab check karteho tab app handel se kartho, handels se surface ka hight 300 nehi he jyada he
@wifeslowdrawings80743 жыл бұрын
28 days ka calculation wrong hai 30*99/100
@MilanKumar-rk6iu3 жыл бұрын
30x28 नहीं 30x99 होगा फार्मूला में 22:40 minutes पर
@mohsinghori89313 жыл бұрын
Video Accha hai..! But Slump test ka Aapko idea nhi hai material dekhne se hi lag rha hai Slump 110-115 Se jyada nhi hai...! Segregation bhi nhi hai..! Bleeding or Segregation kya hota hai Site Per Acche se kaam kerne se Pta Chalega
@balvindersingh63463 жыл бұрын
Very helpfull question
@gulubabu22373 жыл бұрын
Lafarge concerto acha hai kya 🤔
@aspirantcivilengineers3 жыл бұрын
Nice Explain & very informative video 👌
@prashantsahu53943 жыл бұрын
Sir water level kaise krte hai.. Floor ko up ya down Krna ho.. And floor slope kaise dete hai.. Theory video banao sir... Plz Plz plz sir
@mahadialimam87873 жыл бұрын
ভাই, বাংলা দেশীদের জন্য বাংলায় ভিডিও দিলে ভালো হয়।
@reader59332 жыл бұрын
Very good job sir
@civilabhiyantaclasses-by-m70103 жыл бұрын
Sir plz ek video brick test ka bhi or tiles ka bhi .waiting for positive response
@engineeringsolutions35163 жыл бұрын
Thanks for this amazing content,
@civilpower6103 жыл бұрын
kzbin.info/www/bejne/n6S6h6uEisujn7c
@SantoshSingh-fj8fs2 жыл бұрын
Sir..agar column remound hammer testing me fail ho jaate hain too uske baad ky kare... hardness badane ke ky tarike honge
@_fan_video_0993 жыл бұрын
Thnks for this type of video sir👍
@Rajeshbandre73103 жыл бұрын
Most useful video 👍
@officialerdharmendrapatel51183 жыл бұрын
Compaction test krana hain soil ka ho jayega kya ji
@allrounder79493 жыл бұрын
Mai technician ka kaam Karta hu 8 sal se slump mai stamping karne ka tarika Or utjane ka tarike sehi nehi hai . concrete dekhke malum hoga gaya 100 slump ka upar nehi jayega
@anuraggaur57932 жыл бұрын
Road Estimator Software pe video bana dijiye plzz plzzz☹☹☹
@nbverma2353 жыл бұрын
Very informative video sir
@avinashmahapure83153 жыл бұрын
Sir ultrasonic ka bhi video
@imtajali37233 жыл бұрын
So important video ❤️❤️
@ajeetaher14903 жыл бұрын
as per new amendment slump cone test also done in 3 layes
@Education-r1f11 ай бұрын
22:37 , here you are wrong , instead of taking 99 which percent of strength achieved bu concrete 28 days , you took 28 which is no. Of days
@rajivranjansingh43102 жыл бұрын
Nice video very helpful
@MohitYadav-dl4ik3 жыл бұрын
Sir please batiya roof may bend ayga Gaya bataiye abhi Kya
@raviartist84572 жыл бұрын
30*28/100 ya 30*99/100 sir? 22:44
@prawingajbhiye88163 жыл бұрын
Very Nice..thanks
@shaktisehgal97772 жыл бұрын
Sir after how many days should we check rebound hammer test after pillar casting ?
@Journey-Moment3 жыл бұрын
Which type of rod should be used for tamping in case of slump test?
@GODZGAMINGYT9292 жыл бұрын
Tamping rod...
@mahima35012 жыл бұрын
Sir slump cone me b 3 layer hoti h. 4 layer modified wale me hota h.
@anantmalusare29113 жыл бұрын
Wonder full information
@manmagicman81492 жыл бұрын
hi bro. i have contruction plan for 10000 sqft slab G+1. do we really required Soil Report ? pls advice
@AKHAND.BHARAT.SP.PANDEY Жыл бұрын
Better to get report
@MAURYAffFASTCLIPS-cj5dz3 жыл бұрын
Sir ....plz provide us details of companies who r providing a internship in ludhiana. ....
@nagarajup13923 жыл бұрын
Plz this is not procedure for filling the slump cone should be filled with scoop
@Karthik_0023 жыл бұрын
Sir please English mein numbers boliye. Muje hindi samaj me Atha he. Numbers teek se nahi Atha. Mein south se hoon sir Mein regularly dektha hoon aapka video. Please kijiye
@vipulsahu92732 жыл бұрын
Sir after 28days compressive strenght ka formula M30 concrete me 30*99/100=29.7 kn/mm2 hoga
@mickyjassal6117Ай бұрын
Amezing 😮😮
@bijnortractorfans70783 жыл бұрын
My friend i'm not engineer but I know about concrete because i'm also did this work in kuwait international airport so I want a job
@Itscricket25 Жыл бұрын
Agar temperature jiada hoyega 35 degree se..to keya problem hoyega concrete ma.
@ShakirUllah-c9i4 ай бұрын
Sir slump leyar is three or four??
@rakeshpancheshwar13503 жыл бұрын
Wahh sir hamne bhi kiya college me
@technicalengineeringsking91342 жыл бұрын
I have 6+ years experience in which 4 years in water supply and sewage project and 2+ years in road construction project.. Join in 10-15 days
@heartless43943 жыл бұрын
Sir, thermometer ka concrete inserting time k liye kya refrence code h ???
@moizsalah49633 жыл бұрын
Imp question whether u can answer it or not Till which grade Slump test is carried out??M30/40/50 Simultaneously u forgot about one test of concrete which the people are unaware of. Waiting for your reply...
@madeeasyeverythingincivil61363 жыл бұрын
kzbin.info/www/bejne/fHvTfp6ggZV4nJI
@mukeshverma1007 Жыл бұрын
Cube bharne ka frequency pura galt hai aor slup cone bhi test galt hai
@rajshribarmate27803 жыл бұрын
Sir ......area of cube is (side )×side ×side ....and you are taking only (side × side ) and compressive strength check for 28 day ....the calculation is (30×99/100) If l m not wrong ....plz correct me ??
@Amiyaaaaaaaaaa3 жыл бұрын
Side ×side× side volume hota hai bhai
@Amitkumar-cu2pk3 жыл бұрын
Sir concrete mix design se video banaye plz
@kailash_kanheri4963 жыл бұрын
Cube test me constant add krna hota h For example M30 design taken 38.5
@Karthik_0023 жыл бұрын
Target strength
@SaifAli-ve5gb2 жыл бұрын
Informative
@mdkhan50079 ай бұрын
love you brother thank you
@pradeepshriyanvlogs3 жыл бұрын
cone properly not removed. that's only slump value get lower