Temperature Test of concrete on site | Big reason of cracks in concrete | Quality Engineer

  Рет қаралды 23,026

Civil site visit

Civil site visit

Күн бұрын

Пікірлер: 17
@kundanramani8971
@kundanramani8971 2 жыл бұрын
Knowledgeable video.. thanks sir ❤️👍
@baltichannelskardu
@baltichannelskardu 2 жыл бұрын
Thank you 🌸🥀🌟❣️ Watching from Pakistan
@kmkuldeeppal6574
@kmkuldeeppal6574 2 жыл бұрын
Tahanks sir 🙏🏻
@princesingh-807
@princesingh-807 2 жыл бұрын
Sir RE wall ka video bhi banye
@AfzalKhan-zt8nf
@AfzalKhan-zt8nf 2 жыл бұрын
Sir agar 12 to 18c hojeye per keya hoga
@divyanshumishra7702
@divyanshumishra7702 2 жыл бұрын
Sir thumbnail change kr do, पूछेगा कि jagah पुषेगा ho gya hai
@kumarankit6502
@kumarankit6502 2 жыл бұрын
Sir. High performance concrete ka kitna temp hona chahiye..
@shekharrr_Singhhh
@shekharrr_Singhhh 2 жыл бұрын
Sir Please Tell The Callibartion Report How We Check...
@gulshankumar-hc2gn
@gulshankumar-hc2gn 2 жыл бұрын
Sir, agar cube test fail ho jaye for kaun sa test krenge...??
@bijaymauryapv589
@bijaymauryapv589 Жыл бұрын
rebound hammer test and if rebound hammer test fail then core cutter test,
@mohsinghori8931
@mohsinghori8931 2 жыл бұрын
Suppose Aapke Concrete ka initial temprature 38.9°C hai, Or After Placing temprature 44.5°C tab karoge..?? Tm Rejected kerna hai kya..??
@Nalandafilmsno1
@Nalandafilmsno1 2 жыл бұрын
DLC KA REPORT SIR
@vishaljogani5118
@vishaljogani5118 Жыл бұрын
Concrete collapsible in video. ....
@MohdFaiz-du3mp
@MohdFaiz-du3mp 2 жыл бұрын
Cube test ka result toh 7 days Or 28 days pe aata h.. Uska kya faida
@engineeringlife9725
@engineeringlife9725 2 жыл бұрын
If you need Any information relative Civil Engineering Field ' So touch me 👇🏼 kzbin.info/www/bejne/g6nMhYKZfdZ1mc0 Must be watch
@maskedwolff5375
@maskedwolff5375 2 жыл бұрын
Wo test kia jata hai ki uska strength gain hua hai ya nai, if cube test result is failed, from actual site core cut sample test krte hai, if core cut result is ok then concrete accepted, if core cut test is fail We went for load test _ DL +1.25LL apply. For 24 hr after 24 hr remove the load if deflection recovery is >75% then ok, if 82% needed inna nai hua to structure reject kr dete hai.
@MohdFaiz-du3mp
@MohdFaiz-du3mp 2 жыл бұрын
@@maskedwolff5375 thanks brother
Compressive strength test of concrete cube | Cube test Procedure
14:01
Civil Site visit
Рет қаралды 667 М.
What To Do if The Concrete Cube Fail Even After 28 Days | Next Step After Concrete Cube Fail in Test
11:28
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 3,3 МЛН
Slump test full procedure | concrete test | practical live on site
6:49
Civil Site visit
Рет қаралды 98 М.
What is Workability of Concrete | Workability of Concrete effect on Concrete || By CivilGuruji
7:20
Determination of Dry Density of soil compaction test by sand replacement method in hindi road cons |
19:51
techgoyal “tech guru” construction guru
Рет қаралды 140 М.
Slump Cone Test | Slump Test Procedure , Values & Type
9:57
Civil Site visit
Рет қаралды 1,3 МЛН