Closed Loop (Hydrostatic) Charge Pressure

  Рет қаралды 137,465

LunchBox Sessions

LunchBox Sessions

Күн бұрын

Make sure you've watched our previous closed loop / hydrostatic videos (Part 1: • Closed Loop Systems - ... Part 2: • Closed Loop (Hydrostat... ). Now, we're going to go deep on the charge pump. What's it for? What are its flow paths? What pressure values can you expect to see it produce?
We make these animations by hand, and you can play with them yourself on our eLearning website www.lunchboxse...
Follow us for more great videos and learning content on your preferred social network.
LinkedIn: / cd-industrial-group-inc-
Facebook: / lunchboxsessions
Google+: google.com/+lu...
Twitter: / lunchboxsession

Пікірлер: 42
@michaelcostello6991
@michaelcostello6991 5 жыл бұрын
Really great video. My lecturer would never be able to explain this like you have in this simulation. Amazing !!!
@HauNguyen-tn3vn
@HauNguyen-tn3vn Жыл бұрын
what happen when turn the swash plate from full angle to zero intermediately , the remain flow will pass through hot oil relief??
@raminalikhani2262
@raminalikhani2262 4 жыл бұрын
Hi there, I have a little problem with a hydraulic circuit, would you please help me,?
@michaelcostello6991
@michaelcostello6991 5 жыл бұрын
P.S. I have signed up at lunch box sessions website
@GarranGossage-z2m
@GarranGossage-z2m 5 ай бұрын
I'm always blown away by the quality of your videos. Great content, explanations, and graphics. Keep up the good work!
@samirboualem3547
@samirboualem3547 2 жыл бұрын
Please What could be the issue when a shuttle valve fluctuate between 200psi and 500 psi, for your information charge pump was adjusted 400psi and shuttle valve was adjusted 350psi, I had replaced shuttle valve but still the same issue, I have doubt maybe be one of 4 motors failed, what do you think?
@johneduardolaborem1
@johneduardolaborem1 7 жыл бұрын
Goodnight. excuse my English. It is not my language I have a caterpillar crawler loader. Its transmission is hydrostatic. Inside it uses two piston pumps. Which are driven by two hydraulic cylinders that move the oscillating plates. This transmission carries a load sensing system, which works directly with the engine revolutions. Has pilot valve, servos, main control valve etc. Has several points of pressure. One of them is called charge pressure. Is actually a pilot pressure. When I activate the pumps with the machine stopped, brakes on. This pressure does not just fall. But also that it oscillates. The manual tells me it can not fall to less than 100 psi. And falls. But it rises again and falls again. The manual tells me that an indication is possible that there is excess leakage inside the piston pump. The fault is progressive, it gets worse and worse as the oil heats up. my question is. If there is leakage inside the pump, should not it fall and stay there? Bone should not rise again, then fall. Or will I miss any adjustments? Thanks here I leave the link kzbin.info/www/bejne/mpK4p3evq7Kto8k. The hydraulic scheme is very similar to this. I believe that leaks break the bonds in unity. I want to add that the traction motors have no leakage since they block them, and the fault continues. Then, in a few words. My question is simple. A low load pressure is indicative of a leak in the main pumps? Is this why when I turn the lever fnr to max foward the oscillating plates come in and out? The load pump is gears and was tested on a bench and that's fine. I leave another link for you to see part of the system. Is very similar to the one you speak. Thank you. Https://kzbin.info/www/bejne/aKKalJ-InbqCp9k
@arifindwi6121
@arifindwi6121 3 жыл бұрын
Hi, what if the pressure is unstable when the motor is off? It should be stable at 300 right? But it always drop to 260 every 3 seconds. Thanks.
@Mikemrs781
@Mikemrs781 6 жыл бұрын
Why is the tank line in blue passing through the msin pump again on its way to the tank?
@sammy-me4xn
@sammy-me4xn 4 жыл бұрын
Bcoz its a closed loop circuit or else each pump rotation has to suck fresh oil from tank, as there is pump leakage and also pump case drain (not shown ) some hot oil passed off and cold oil is replenished by charge pump
@harrisonfowler4461
@harrisonfowler4461 6 жыл бұрын
I have a video on my channel of my charge pump on a garden tractor. Could you take a look and tell me if it sounds like it's cavitating? I think it is, but I'm not 100%. I am certain that the noise is coming from the charge pump. I've never heard it before.
@Joscope
@Joscope Жыл бұрын
Is the best place to filter and cool the oil the outlet of the charge pump?
@JP-hk7qs
@JP-hk7qs 4 жыл бұрын
I have little problem with Hydrostatic pump please can i get help
@garymatusavige3639
@garymatusavige3639 4 жыл бұрын
Ok on a eaton 70144 would I tee the charge line to get pressure reading
@jcolivera881
@jcolivera881 4 жыл бұрын
Is the Eaton motor ran off of charge pressure?
@garymatusavige3639
@garymatusavige3639 4 жыл бұрын
@@jcolivera881 not sure mine is still working
@pradachannel7940
@pradachannel7940 4 ай бұрын
how to decrease motor rpm?
@RailFan92
@RailFan92 6 жыл бұрын
Great video, very useful thanks
@thunderbirdbob1
@thunderbirdbob1 7 жыл бұрын
I have a eaton 70145 lal pump with a charge pump. your video helped me understand it a little bit better but not completely. could someone contact me to help me out?
@thunderbirdbob1
@thunderbirdbob1 7 жыл бұрын
LunchBox Sessions ok I just took a look at your part 1 I think I understand now. if I do have any more questions I will contact you thank you vary much. if you check out my video my most recent one shows you what I'm doing. if you have any suggestions please let me know. thanks bob
@رافضيحب
@رافضيحب 3 жыл бұрын
How can I get this program
@NorAlb_Chainsaw_Carver
@NorAlb_Chainsaw_Carver 5 жыл бұрын
How is it possible that the charge pump can open the check valve at 260psi yet fails to open it at 300psi when it's going over relief?
@diegoortiz1012
@diegoortiz1012 5 жыл бұрын
I think that it opens the check valve at 300 psi, but just for a brief moment: as son as the swash plate is centered, oil might flow long enough to put pressure right after the check valve, but once both pressures are 300 psi, oil can't keep flowing through either check valve and it goes through the charge pump relief valve.
@simclardy1
@simclardy1 4 жыл бұрын
The pressures balance on both sides if the check valve so no flow.
@ustarecepusta
@ustarecepusta 4 ай бұрын
Teşekkür
@vivekpandey841
@vivekpandey841 4 жыл бұрын
What advantage close circuit
@archaosy
@archaosy 7 жыл бұрын
Why not redirect the Hot Oil Shuttle directly to the motor to cool it down? The pump already gets cooled oil from the charge pump, while I think the motor could overheat this way. Am I wrong? Nice video still thx!
@lunchboxsessions
@lunchboxsessions 7 жыл бұрын
You are correct that sometimes the output from the hot oil shuttle is directed through the motor case. On a motor with two case ports, one for flushing-in and one for draining-out, this is then called a full flushing loop. Help with cleaning away contaminants and wear particles, and can help a little bit with heat. Many motors in closed loop, hydrostatic systems now self-flush using a small amount of the main loop, inlet flow and then draining back to tank on a single case drain line. Great question, thanks for writing. - Carl
@archaosy
@archaosy 7 жыл бұрын
Thank you very much for the answer. Much appreciated!
@jcolivera881
@jcolivera881 4 жыл бұрын
LunchBox Sessions this is the case an a lot of poclain driven self propelled equipment!
@shibaramreddy1874
@shibaramreddy1874 5 жыл бұрын
Accumulator charging system
@jovanni_orb5116
@jovanni_orb5116 5 ай бұрын
yes
@rajarao1200
@rajarao1200 Жыл бұрын
Super
@jovanni_orb5116
@jovanni_orb5116 Жыл бұрын
helpful
@OriginalAyron
@OriginalAyron 4 жыл бұрын
What would cause a huge drop in charge pressure when the main pump is in full displacement. The identical pumps drop from 350 to 300 and the faulty one drops to 150
@JP-hk7qs
@JP-hk7qs 4 жыл бұрын
I have the same problem did u solve that
@OriginalAyron
@OriginalAyron 4 жыл бұрын
@@JP-hk7qs turns out it was bypassing in the motor which had a failed piston. You could visually see the motor slowdown/stop at a certain point during the revolution
@jcolivera881
@jcolivera881 4 жыл бұрын
I was going to say check your case drain flow on whatever those pumps were running.
@islamtaha6414
@islamtaha6414 4 жыл бұрын
You are My teacher
@andibachrul5942
@andibachrul5942 4 жыл бұрын
Amazing
@vivekpandey841
@vivekpandey841 4 жыл бұрын
Nice
@workwillfreeyou
@workwillfreeyou 6 жыл бұрын
So the main pump case has up 300psi?
Closed Loop (Hydrostatic) Systems - Part 2
9:31
LunchBox Sessions
Рет қаралды 74 М.
Teaching: Relief Valve Basics
51:00
LunchBox Sessions
Рет қаралды 141 М.
Nastya and balloon challenge
00:23
Nastya
Рет қаралды 70 МЛН
Как мы играем в игры 😂
00:20
МЯТНАЯ ФАНТА
Рет қаралды 3,3 МЛН
Minecraft Creeper Family is back! #minecraft #funny #memes
00:26
Closed Loop Systems - Part 1
4:23
LunchBox Sessions
Рет қаралды 72 М.
CLOSED LOOP HYDROSTATIC PART 1
15:02
hystat
Рет қаралды 57 М.
EXPLAINED: How a Hydrostat Transmission Works
8:56
ModernSurvivalists
Рет қаралды 68 М.
Load Sensing Systems: Pump Control & Valve Bank Mysteries
1:33:35
LunchBox Sessions
Рет қаралды 70 М.
Meter-In vs Meter-Out
6:27
LunchBox Sessions
Рет қаралды 315 М.
Section 1 - Modern Hydraulics Training
15:37
Senergy Petroleum
Рет қаралды 141 М.
Do Pumps Create Pressure or Flow?
10:38
Practical Engineering
Рет қаралды 1,4 МЛН
Давайте поцарапаем iPhone 16 Pro Max!
0:57
Wylsacom
Рет қаралды 2,7 МЛН
Обзор на 16 айфон
1:01
Тыковка из Германии
Рет қаралды 745 М.