Been and going on more courses about this. Your video has made it easier to understand than some of these course's.
@sodig876 Жыл бұрын
Great video that's made it much easier to understand 👌
@alfypierri8022 Жыл бұрын
Very well explained. Thanks you
@valentinbelchev33012 жыл бұрын
Great video and explanation. Thanks 👍
@jockster55252 жыл бұрын
Thanks for your efforts 👍...
@TDOWLP2 жыл бұрын
Thank you. very good explanation.
@aliatas66476 ай бұрын
In your experience, is one CCT enough to feed UFH & rads? or would you recommend two CCTs, one for each zone? Thanks for the video 😁
@craigwebster74052 жыл бұрын
Nicely explained 👍
@hufartd Жыл бұрын
Instead of a non return valve on the radiator return (which I feel are very restrictive) I used a zone valve instead wired in parallel with the radiator pump to stop back flow while underfloor only was running. Do you see any issues with this?
@randomcamerajunk6977 Жыл бұрын
Will you not have interplay between the 2 pumps on the one CCT? Just add a second pair of ccts for the UFH after the higher temperature rad ccts 🤔
@CommercialGasEngineerVideos2 жыл бұрын
You're back. I didn't realise. Lovely jubbly.
@henrybartlett1986 Жыл бұрын
Kimbo’s course is life changing.
@stewartharrod17062 жыл бұрын
Amazing video
@simonkay22732 жыл бұрын
Great video as always think I need to get on some of these courses.
@thementalgasman3tgasmainte3172 жыл бұрын
Great courses to go but they’re not easy
@craigwebster74052 жыл бұрын
Nothing worthwhile is
@grantbrown60892 жыл бұрын
If I was going to add a h/w circuit to this would that need its own pump too thanks and great video👍🏻
@paulreece7148 Жыл бұрын
Hi, I’ve piped up a couple of systems after watching this. One question o have is, if the ufh manifold was say 15 metres away would you for an extra pump on that circuit to help with the flow?
@thementalgasman3tgasmainte317 Жыл бұрын
No you shouldn’t need the xtra pump it will work with out , unless it’s 15m of elbows and restrictions then you would need to give consideration to reducing that resistance
@magicno001 Жыл бұрын
I guess your manifold in that plan is drawing its own water as in not an injector manifold?
@leepickett36552 жыл бұрын
Really good this mate 👍
@mikecave41542 жыл бұрын
Could the normal method off boiler pump Doing upstairs rads and downstairs underfloor heating to the manifold on a normal s plan without close coupled tees there a lot out there without them
@SisterAbdullahX2 жыл бұрын
They are all high flow temp
@jasonwhittle50082 жыл бұрын
Did you wire the external pumps to the orange / switch live in wiring centre mate 👍
@thementalgasman3tgasmainte3172 жыл бұрын
On this occasion I wired the pump to the brown on the zone valve as the switch live back from the UFH would energise the radiator pump when there is no demand
@ginola6022 жыл бұрын
Great video !
@d.costacostagliola72982 жыл бұрын
Top video mate
@joncoke82082 жыл бұрын
GreT video Mate how Much r these courses roughly? Also recommend any breakdown courses you recommend?