CoGri Middle East - Wire Guidance Installation For Very Narrow Aisle Trucks (VNA) or AGV Systems

  Рет қаралды 10,762

CoGri Group

CoGri Group

4 жыл бұрын

CoGri Middle East LLC annually install in excess of 17,000m of wire guidance for Materials Handling Equipment (MHE) and Automatic Guided Vehicles (AGV’s).
We offer our design & installation services throughout the GCC & wider region, supporting MHE suppliers & Clients directly.
Project Process
• 20 Seconds: The wire guidance positioning centrally to the aisle is critical for the safe & efficient operation of the MHE/AGV. The rack to rack distance is measured at regular intervals down the aisle to record any variances and adjust the wire position accordingly.
• 30 Seconds: A chalk line is used to mark a continuous line down the aisle, connecting all the centre marks made earlier.
• 45 Seconds: Where the wire will intersect with a saw cut/construction joint, the cut/joint is filled with a suitable joint sealant. This protects the wire once operational.
• 1 Minute: The wire cut is installed by a 2 man team. One man to operate the floor saw and one to immediately vacuum up the cutting residue. The wet cutting process eliminates any dust creation.
• 1 Minute 12 Seconds: The depth if the cut is routinely checked by the team to ensure a constant cut depth is produced. A constant cut depth means the wire will remain at the specified desired distance below the floor surface - producing a consistent signal strength for the MHE/AGV.
• 1 Minute 28 Seconds: If power supply is an issue on site, we can use our own small mobile generator. This means the wire installation team are self-sufficient and do not hinder any other ongoing operations.
• 1 Minute 45 Seconds: Once all cutting is finished, the wire is rolled out and dropped in to the cut.
• 1 Minute 55 Seconds: Where required, wires are joined professionally using solder and heat shrink.
• 2 Minutes 15 Seconds: Sealant is mixed in the containers supplied. This is a clean & safe process.
• 2 Minutes 30 Seconds: After being poured in to the dispensing gun, the sealant is applied to the cut to seal the wire in to the groove.
• 2 Minutes 40 Seconds: Any excess sealant is removed, leaving a smooth finish level with the floor level.
• 2 Minutes 50 Seconds: At the wall position where the line driver/frequency will be located, the wire is passed through a protective conduit and this is then fixed securely to the wall.
• 3 Minutes: Before being connected to the line driver/frequency generator, the continuity and resistance is verified & recorded.
cogrimiddleeas...

Пікірлер
Hyster Wire Guidance - Part 1, The Driver.
6:59
Scrufdog
Рет қаралды 406
Sunglasses Didn't Cover For Me! 🫢
00:12
Polar Reacts
Рет қаралды 5 МЛН
the Blackpool most people don't see!
12:04
Honest Places
Рет қаралды 1 МЛН
Flymo Robotic Lawnmower 1200R - The Boundary Wire and Guide Wire
8:44
Flymo Lawnmowers
Рет қаралды 41 М.
DIY Driveway Gate Vehicle Detector Cut In Loop Installation
7:06
Customer experience - Hachette UK - Linde VNA trucks
4:16
Linde Material Handling (UK) Ltd
Рет қаралды 1,8 М.
JUNGHEINRICH-VNA-forklift-truck with rail-guidance
1:02
Rotomatik Kent
Рет қаралды 6 М.
CoGri Middle East - High Tolerance Flooring Project
2:07
CoGri Group
Рет қаралды 619
Sunglasses Didn't Cover For Me! 🫢
00:12
Polar Reacts
Рет қаралды 5 МЛН