mau tanya om., untuk tekanan freon brp ya, dan butuh berapa lama untuk mencapai suhu minus
@pakwoluchanell39725 күн бұрын
Freon_nya pakai jenis apa bosss...?
@eyisinatra-ru7so Жыл бұрын
Salam kenal fery dari sby suhu.. Teknisi junior bonex pingin blajar banyak pendingin suhuku..
@jayahadiservis Жыл бұрын
Suhu tempratur..
@baimfirmansyah69348 ай бұрын
Real masuk akal dan murah
@jayahadiservis8 ай бұрын
Siaaaaap....
@nurawaludin-yo3sg Жыл бұрын
Pake exspansi kah itu om. Atw pipa kapiler
@titazahra6885 ай бұрын
Mantap bos
@jayahadiservis2 ай бұрын
Trimakasih... 🙏🙏🙏
@tranding47719 ай бұрын
Untuk dinamo nya pake apa kk punya sya mati 1 mhon info nya
@jayahadiservis9 ай бұрын
Dinamo yg mana y...
@didiarwadi174 Жыл бұрын
saya pake kapiler 0.54 2mter pipa pake outdor 5mter suhu ruangan -8 kang kalau mau -15 apa perlu ganti kapliler tah kecilin pake 0.42
@jayahadiservis Жыл бұрын
Kalo mau pake 0,42 g papa yg penting mesin masih aman.
@didiarwadi174 Жыл бұрын
pake berapa meter ya kang panjang nya
@jayahadiservis Жыл бұрын
@@didiarwadi174kalo itu saya belum pernah coba. Yg saya coba baru mnggunakan 0,54
@didiarwadi174 Жыл бұрын
@@jayahadiservisoke kang saya coba deh
@tkhchief Жыл бұрын
Mas kalo Jayahadi juga ada di malang dan solo apa tidak??
@jayahadiservis Жыл бұрын
Call WA 085214119448
@didiarwadi174 Жыл бұрын
mantaaap banget kang .. ow ya kang saya sudah bikin ukuran T2.8 L3 P4 pake outdor 2pk x2 daikin tapi cumqn bisa minus 8 kang . ow ya kang yanga ku tanyakan apakah masih bisa naik minus nya ke -15 udah runing 24 jam kang .makasih mohon di jawab kang kekurangan nya apa ya kang.
@jayahadiservis Жыл бұрын
Ndak bisa... Kalo buatan saya minus 8 itu suhu pada ruangan. Kalo d efap bisa sampai minus 18 sampai minus 20.
@didiarwadi174 Жыл бұрын
@@jayahadiservis iya ini suhu ruangan minus -8 kang apa kah bisa naik lagi ya kang apa yang harus di rombak lagi apa perlu satu outdor lagi ya kang
@jayahadiservis Жыл бұрын
@@didiarwadi174 bisa sampai minus 14.
@jayahadiservis Жыл бұрын
@@didiarwadi174 call aja biar lebih jelas.
@didiarwadi174 Жыл бұрын
@@jayahadiservis apa yang kurang ya kang
@lintangjauharhafeezaraya76539 ай бұрын
Mas brp hrga nya kl sm panel nya. Mks
@jayahadiservis9 ай бұрын
Call aja pak..
@jayahadiservis9 ай бұрын
Call aja 085214119448
@tkhchief Жыл бұрын
Itu hanya pipa outdoor ac...listriknya semininal mungkin
@Koperasibaitulmal7 ай бұрын
Tertarik
@jayahadiservis2 ай бұрын
Siap..
@ezablackhawks4125 Жыл бұрын
gan kalau boxnya ukuran 1,5 M2 apa bisa pakai kompresor kulkas ya?
@jayahadiservis Жыл бұрын
Maaf saya belum pernah coba.... Sebenernya bisa tp harus menyesuaikan ukuran mesinya.
@ahmadrifai99 Жыл бұрын
Kalo pipa evaprator 1pk d tempel ke media stainless bisa mendinginkan cepat gk bang? Bisa minus berapa kira?
@jayahadiservis Жыл бұрын
Maaf saya belum pernah coba. Rencana mau buat pending jenis apa ya. Pendinginan itu ada beberapa media contoh yg saya buat itu pendinginn dengan media udara. Dan media itu d sesuaikan dengan kebutuhanya.
@ahmadrifai99 Жыл бұрын
Saya mau ganti tabung mesin ice cream saya yg kecil pake tabung yg besar,,agar suhu biar cepat dingin dan konsisten/tinggi.
@jayahadiservis Жыл бұрын
@@ahmadrifai99 bisa tp mesin juga harus d sesuaikan dengan beban. Beban semakin banyak maka mesin juga harus semakin besar. Semuaitu perlu penesuaian.
@ahmadrifai99 Жыл бұрын
Owh iya,,ok mksh bang.
@jayahadiservis Жыл бұрын
@@ahmadrifai99 sama sama smoga bermanfaat.
@tkhchief Жыл бұрын
Belum ada bocoran harganya...pokok nya ukuran box L300 ya...berikan harga yg terbaik ya...
@jayahadiservis Жыл бұрын
WA 085214119448.
@MuhamadAndik-i7b Жыл бұрын
Bos mau nanyak apa kuat klo 2 pk buat ruangan 3x3x3 meter
@jayahadiservis Жыл бұрын
Kalo g kuat gunakan 2unit.
@jayahadiservis Жыл бұрын
Dan ter gantung ke fungsianya.
@MuhamadAndik-i7b Жыл бұрын
Oke boss mkasih
@ajimuhaimin4681Ай бұрын
Semua abis berapa bos
@jaelanijteknik8334 Жыл бұрын
Gunakan outdoor ac 2pk freon r32 bisa
@jayahadiservis Жыл бұрын
Bisa bang..
@AnasRusianto-dm8ov Жыл бұрын
Berapa tekanan psi utk outdoornya..?
@jayahadiservis Жыл бұрын
Di sesuaikan saja sesuai dengan jenis preon dan ampernya..
@alialinaali4056 Жыл бұрын
❤❤❤
@haidarassyauqi638 Жыл бұрын
Weleh bosss kerjaanmu tekan jakarta
@jayahadiservis Жыл бұрын
Betul... Allhamdulilah...
@mswondo8 ай бұрын
Spill total biayanya, termasuk biaya pembangunan box ruangannya
@jayahadiservis8 ай бұрын
Wa 085214119448
@tkhchief Жыл бұрын
Mas kalo di Malang bisa melayani gak??
@jayahadiservis Жыл бұрын
Bisa pak
@majharulislam5950 Жыл бұрын
Great job done brother. Could u kindly tell us, outdoor unit is from AC with the same compressor. Its compression ration is just half of the Refrigerator Compressor. In a long run AC compressor will burn out due to overload on motor coil. In that case have to change the compressor by a Refrigerator one. Or can connect 2 nos AC compressor in cascade, which needs automation for safety. Would be greatful, if u reply on my queries for learnings. Thanks.
@jayahadiservis Жыл бұрын
the first step that needs to be done is. how to make the AC compressor work 24 hours a day without overheating. actually there are still many things that need to be done, including by adjusting the evaporator. turn off the condenser. determine suction pipe. define refrigerant.
@majharulislam5950 Жыл бұрын
@jayahadiservis thanks lot for your prompt response, brother. I am from Bangladesh, want to do this experiment with your guidance. Sofar I understand, without doing any modification inside the Compressor, we have to reduce the refrigerant flow to maintain Power consumption within the rated current. Formula is KW= Constant value x Flow x Discharge Pressure. Here, for refrigeration application, differential pressure will be 2.5 times. Hence, we have to reduce the Refrigerant Flow 2.5 times. This can be done by; 1. Increasing the Capilary tube length and its dia reduction. 2. Reduction of Refrigerant quantity in the system. 3. Increase Superheat by heat exchanging with Condenser return line. So, suction pressure at Compressor inlet will increase. Hence the differential pressure and the Power consumption will be within the range of normal AC operation. 4. Can replace at higher Latent heat value Refrigerant. Say, replace R134a by R600a. Here, less Refrigerant flow(60%) will give same effect. So, power load on motor will be in range for the operation of Refrigeration mode. 5. Evaporator should be large enough to exchange heat properly with indoor Air. 6. Condenser Fan should run by a separate temperature controllers to get Subcool effect. Hope, by doing all these things, can reduce the overall electrical load on the Compressor motor. Pls help us, by adding/ modifying some suggestions, if needs to be done to get ultimate results.
@farizdaroini6720 Жыл бұрын
Kuat nyala berapa hari bos di minus 10 kebawah?
@jayahadiservis Жыл бұрын
Kira kira menurut kawanku mampu bertahan brapa hari... Barang kali kawan ada pendapat boleh d utarakan barangkali dapat menambah ilmu buat saya dan rekan rekan yg lain harap maklum saya sebagai pemula 🙏trimakasih...
@handyarto5878 Жыл бұрын
Mesin bisa bertahan 1thn bang....jawab zuzur ya bang....
@jayahadiservis Жыл бұрын
Yg paling awal saya buat sudah 4tahun pake merek nasiaonal 1,5 pk.
@ebitmatudak47208 ай бұрын
Berapa panjang pipa evoratornya yg 1 1/2 pk
@limalima66678 ай бұрын
Harga jual berapa bang ? Dan berapa lama ?
@jayahadiservis8 ай бұрын
Call aja pak...
@opakdolar Жыл бұрын
Haraga Berapa bang,, dengan spek yang sama dengan d video ini,,,
@jayahadiservis Жыл бұрын
Call 085214119448
@danipurwanto64528 ай бұрын
Budget berapa sama kontainer nya
@jayahadiservis8 ай бұрын
Menyesuaikan kebutuhan
@onitbh23967 ай бұрын
Kapasitas 2 ton nyampe berapa komplitnya om ?
@jayahadiservis6 ай бұрын
Call aja ...
@RUSTUTECH-o3s3 ай бұрын
Bang untuk ruangan nya , itu ga pake ventilasi ya?
@jayahadiservis2 ай бұрын
G pake pak..
@masyhurialghazali9977 Жыл бұрын
Assalamualaikum, mas minta wa nya yaa, ada rencana pembuatan colt storeage, posisi saya di lampung
@jayahadiservis Жыл бұрын
085214119448
@masyhurialghazali9977 Жыл бұрын
@@jayahadiservis oke, terimakasih mas
@rarawulan206611 ай бұрын
Kontak person nya pak untuk pesan jasanya
@jayahadiservis11 ай бұрын
085214119448
@masodah11649 ай бұрын
@@jayahadiservisbuat es batu apa beku bos
@caknor6573 ай бұрын
Pengen tapi jauh lokasi
@tvnasionalindonesia Жыл бұрын
Itu bisa beku es gak
@jayahadiservis Жыл бұрын
Bisa tinggal di seting suhunya...
@khoirulanam98449 ай бұрын
Itu pake compresor murni punya AC y
@jayahadiservis9 ай бұрын
Betul saya hanya menggunakan kompresor ac..
@kenzieatmaening9 ай бұрын
Konsumsi daya nya brapa watt om?
@jayahadiservis8 ай бұрын
1500 watt.
@tkhchief Жыл бұрын
Seukuran 1 box l300 box...
@mujiono23597 ай бұрын
Relay dc kaki berapa bang?
@jayahadiservis2 ай бұрын
Kaki 4 dan kaki 5.
@NoerCholik-g4m Жыл бұрын
Bocoran harga nya om
@jayahadiservis Жыл бұрын
Call aja 085214119448
@janggut96784 ай бұрын
Habis brapa bos?
@jayahadiservis2 ай бұрын
Call aja pak.
@Juragan99Snack Жыл бұрын
Harga brp mas
@jayahadiservis Жыл бұрын
Call wa 085214119448
@BayuSudarmawan-dv9cq Жыл бұрын
Klo untuk penyegaran buah dan sayur suhu brp pak
@lovav5255 Жыл бұрын
Harga berapa bang
@jayahadiservis Жыл бұрын
Call WA 085214119448
@tvnasionalindonesia Жыл бұрын
Minta wa nya
@jayahadiservis Жыл бұрын
085214119448
@ansarahmed1021 Жыл бұрын
وعلیکم السلام ورحمۃ اللہ وبرکاتہ
@SusanNadya Жыл бұрын
Bisa minta no kontak
@SusanNadya Жыл бұрын
Sy ada rencana membuat cold storage kapasitas sedang untuk transit sayuran dan ikan di kota langsa