COMBI Boiler Heat Exchanger - BAXI Main Eco 30 - How To Replace Plate Heat Exchanger

  Рет қаралды 11,902

Handy Singh

Handy Singh

Күн бұрын

Пікірлер: 42
@phillipjones5246
@phillipjones5246 3 ай бұрын
great video, hopefully this will solve my problem, every so often my boiler(main 30) , if left over night without any use the boiler will not fire up, no heating or hot water, so will try this, thanks again
@Quarms95
@Quarms95 2 жыл бұрын
Thanks for the video! A Great walk through! Much appreciated!
@Besty34
@Besty34 2 жыл бұрын
Excellent video, just changed mine thanks you made it easy
@handySingh
@handySingh 2 жыл бұрын
No problem mate. Subscribe to see further future videos which you may find useful. There will be a variety on this channel. Cheers
@foxman2137
@foxman2137 2 жыл бұрын
Great, that was very clear. The exchanger could have been cleaned rather than new.
@koncorePh
@koncorePh Жыл бұрын
Thank you ! Just had one like this today
@wayner1521
@wayner1521 Жыл бұрын
Thanks for this have just successfully changed mine and have nice hot water again. However, when removing I couldn’t find any rubber washers and couldn’t fathom how to replace with new ones? I can’t see at the back either when doing it. It’s on and no leaks so will the okd washers just be sitting flat to the pipework or something?
@handySingh
@handySingh Жыл бұрын
Hi Wayne, thanks for watching. I'm glad the video was useful for you and helped you out. Yes the rubber can stick to valve end due to heat, it should be fine and still be a good seal as they are thick. As long as you check for leaks once connected up and tested once cover is on. You can also see for any leaks from underneath boiler if there is any. But you will be fine. Cheers handy Singh
@davidleather4032
@davidleather4032 Жыл бұрын
Thanks for the video nice and clear showing how to sort it, It looks like a easy job to do 🙂 I have the same boiler and the temperature is unstable at times when using the shower, ive also had the water pressure rising into the red when we use the heating ( have a wood burner so its rare we use the combi heating much ) and the temperature gauge on the boiler when its not being used will keep fluctuating at times from like 54-58 👀 Is any of them symptoms likely to be related to the heat exchanger issue ?
@handySingh
@handySingh Жыл бұрын
Hi David, I'm glad you found this video useful. Yes your boiler symptoms sound more like a expansion vessel failure and also potentially a temperature sensor gone. What is the pressure of boiler when the heating is off and cooled down?, as it should between 1 bar or 1.5 bar recommend. Thanks.
@davidleather4032
@davidleather4032 Жыл бұрын
@@handySingh Thanks for the reply back much appreciated and the pressure when not in use is as you say 1-1.5 basically that zone where its meant to be in the triangle. I swapped over the expansion vessel just before covid but maybe its gone again.
@adambusuttil1569
@adambusuttil1569 Ай бұрын
Hi, great video. Ivw managed to change my heat exchanger plate. But now I've got a 60 error on the boiler and not hot water will come out.
@handySingh
@handySingh Ай бұрын
Hi Adam, does it come up with E1 and then 60 after? That would indicate a possible fan fault. Cheers Handy Singh.
@pankajmakwana2300
@pankajmakwana2300 8 ай бұрын
Quite good, thank you.
@sidhusukhdev3669
@sidhusukhdev3669 3 ай бұрын
Handy bhaji how to know which one is top side if no mark on plate ,?
@handySingh
@handySingh 3 ай бұрын
Hi Sukhdev, the plate will only fit one way..the connection point and screws will only align if it placed the right way. When you do it you will notice straight away once placed. Cheers Handy Singh 👍
@allank9874
@allank9874 2 жыл бұрын
Thanks alot for the information 👍
@handySingh
@handySingh 2 жыл бұрын
No problem. Hope the video has helped you out. Cheers Harry.
@joejoejoejoejoejoej
@joejoejoejoejoejoej Жыл бұрын
What gauge is the rubber hose mate?
@handySingh
@handySingh Жыл бұрын
Hi mate, the size is 6.35mm manometer hose. Cheers
@whoisme678
@whoisme678 Жыл бұрын
So, are heat exchangers repaired / refurbished or scrapped ? If they are sold as scrap and the engineer gets money for it?
@wileecoyote5749
@wileecoyote5749 Жыл бұрын
You can clean them. You get money for any scrap metal if you toss it. By itself you'll be lucky to get a nickel
@rayc1503
@rayc1503 Жыл бұрын
Spirits of salts or brick cleaning acid cleans the plate heat exchanger out. Be extremely careful and wear the appropriate ppe.
@stevekunoor
@stevekunoor 8 ай бұрын
i have the same boiler but my issue is heating works fine but hot water from taps goes hot and cold and sometimes stays cold unless i open another tap in the house then it warms up, any ideas what it could be ?
@handySingh
@handySingh 8 ай бұрын
Hi Steve, thanks for watching the video. You know your tap that gets cold would you say that is further away in terms of pipe work is comparison to the one that warms up? Also how is the hot water when the heating hasn't been on? Cheers Handy Singh
@satpal2824
@satpal2824 Жыл бұрын
In my bathroom, when I open the bath tap, the water always stays luke warm, and in my kitchen tap, the water is very hot. Does this heat exchanger cause these symptoms as I already ordered one? Or is the problem somewhere else?
@handySingh
@handySingh Жыл бұрын
Hi Sat, the kitchen tap is normally downstairs and probably the closest to the boiler feed hot water pipe. When the central heating is on don't forget this will Hest the exchanger plate and also divertor valve and the initial surge flow to hot water will initially be extremely hot and then gradually as the pumps flows it will start to cool the water down to regulation set temperature on your boiler that you have selected. The Heat exchanger in mine instance in the video is that there was an internal leak and cold water kept going to heating system return pipe and hence boiler pressure kept increasing and spitting the water out via pressure relief valve. Is your pressure level steady and maintained?
@marley2319
@marley2319 11 ай бұрын
Hi. Is this the main heat exchanger? Is it the same as the potterton titanium 28? I’m asking because the diagram of the inside of the boiler points to the big Circular disc at the back and says that’s the heat exchanger. I’m confused as to what is what? And how long the job takes? Any help would be much appreciated. Kind regards
@handySingh
@handySingh 11 ай бұрын
Hi Marley, it's not the main heat combustion heat exchanger. This is the heat plate exchanger which is different as this transfers heat between 2 fluids...i.e hot water and heating pipes to save energy. The job is very easy to do and should take no longer than 1 hour if you follow the same steps as the video. Hope it helps mate. Cheers Handy Singh
@handySingh
@handySingh 11 ай бұрын
Yes it should be the same part as if you look online it's similar to the baxi ones. Cheers
@marley2319
@marley2319 11 ай бұрын
@@handySingh hi Singh. They guy that was out said it was the heat exchanger and I’m looking at a diagram for the inside of mine and it says the heat exchanger is the big Circular disc. Can’t see the thing you took out on the diagram of my potterton titanium 28. Very kind of you to reply , much appreciated. Cheers.
@handySingh
@handySingh 11 ай бұрын
@@marley2319the main Heat exchanger is what heats the water. The circular disc you mentioned. Is your boiler not heating anything?
@marley2319
@marley2319 11 ай бұрын
@@handySingh Yes everything is still working, heating and water it’s just leaking. It’s a coffee colour so I take it that’s something put in to help with something? Cheers.
@jaspreetathwal1182
@jaspreetathwal1182 Жыл бұрын
My boiler is sending hot water to radiators when heating isnt switched on. Even at night when no taps are being used/thermostat set low, the boiler can be heard running and radiators warm. Could this be heat exchanger or diverter valve?
@handySingh
@handySingh Жыл бұрын
Hi J Singh, sounds more like the boiler is calling for heat constantly which can be either a thermostat fault or if you have a motorised valves for a zone, this could potentially be faulty. Did you get this fixed? Cheers
@jaspreetathwal1182
@jaspreetathwal1182 Жыл бұрын
@@handySingh just changed diverter cartridge last night. See if that solves problem
@handySingh
@handySingh Жыл бұрын
@@jaspreetathwal1182 yeah try that and also see if the motorised head on divertor valve is actually working too.
@jaspreetathwal1182
@jaspreetathwal1182 Жыл бұрын
@@handySingh cool. Ill try that and let you know. Cheers for help
@jaspreetathwal1182
@jaspreetathwal1182 Жыл бұрын
Changed diverter valve but still remains. Thermostat is a honeywell digital thermostat. Reckon its worth changing it?
Boiler heat exchanger blocked. Diagnosed with no tools?
13:53
HeatingGeek
Рет қаралды 44 М.
Smart Sigma Kid #funny #sigma
00:14
CRAZY GREAPA
Рет қаралды 66 МЛН
НИКИТА ПОДСТАВИЛ ДЖОНИ 😡
01:00
HOOOTDOGS
Рет қаралды 2,8 МЛН
I regret not having learned this secret at age 50! I would die without knowing
33:46
How to remove the main heat exchanger on a Baxi Duo-tec or Baxi Platinum boiler
7:28
Baxi - sustainable heating and hot water solutions
Рет қаралды 26 М.
How a combi boiler works @BaxiBoilersUK
6:36
Thornhill Plumbing and Heating
Рет қаралды 2,8 М.
Main Eco Elite | Changing The Diverter Valve & Cartridge
8:17
Advanced Boiler Training
Рет қаралды 17 М.
Baxi Diverter How to service, Start to finish Dr Pipe.
20:34
Gas Training - How To Service A Combi Boiler Baxi 105
33:37
Allen Hart
Рет қаралды 22 М.
Main Combi 30 eco Elite No Hot Water Boiler Repair Accelerated Training
14:56
A+R Central Heating and Boiler Repair Experts Ltd
Рет қаралды 4,5 М.