Finally, someone took his priceless time to explain these themes in a simple language to an apprentice like me. It was really much appreciated
@JerseyMikeHVAC9 ай бұрын
You're welcome. Thanks.
@trevorburgess26432 ай бұрын
Awesome video thank you so much! Two years in the trade mostly doing maintenance on oil and gas boilers. And this makes more sense to me than anything someone has tried to explain …🙏
@yidala69059 ай бұрын
Finally found someone that could explain things so my dumb head could understand
@JerseyMikeHVAC9 ай бұрын
Many times it's on the person teaching... "If you can't explain it simply, you don't know it well enough" ~ Albert Einstein
@AWhite_3 ай бұрын
You are great man. Really appreciated.
@carllinton9 ай бұрын
Thank you Mike for simplifying how a combi boiler works.
@JosephSaeteros-r9j13 күн бұрын
Hello i have a question i installed a navien combi boiler 3/4 baseboard but i main lines is 1/2 pex you think that's a problem
@sfischer970315 сағат бұрын
Great explanation.. thank you
@imanabedini28975 ай бұрын
That's a comprehensive detailed description. Thank you👍
@JerseyMikeHVAC5 ай бұрын
You're welcome!
@AWhite_3 ай бұрын
I live in NJ. Would you be able to help me with the paperwork if i diy the system.
@nicorizzo36077 ай бұрын
Awesome thank you!! Getting ready to hook up my system with raddiant heat in the concrete in my new garge . Found your video very helpful!! Never did this before!!
@alexandrostapantaola19127 күн бұрын
Thank you so much learning a lot from you
@aaronhall43613 ай бұрын
Thank you so much!
@JerseyMikeHVAC3 ай бұрын
You're welcome!
@aaronhall43612 ай бұрын
Does it matter if the flow direction of the primary loop matches the flow direction of the secondary loop?
@JerseyMikeHVAC2 ай бұрын
Ideally you would want your heated supply water from the internal pump to inject into the main loop and flow away from the suction side of the internal pump. Going the other way will allow hot water injected into the main loop to be drawn directly back into the internal loop and you'll have shorter cycling of the burners on limit controls.
@johnnybgoode55989 ай бұрын
Can you do some vids on troubleshooting combi's and heat only wall hungs? Not much on the net about them. Anything would help. Love ur vids. Very detailed and informative. Thanks for your work!
@JerseyMikeHVAC9 ай бұрын
I'll certainly try. Thanks!
@BeeBombard2 ай бұрын
100% awesome video
@brianmcdermott17189 ай бұрын
A very good example. Thank you Mike.👍👍👍👍👍👍👍👍👍.
@JerseyMikeHVAC9 ай бұрын
Very welcome
@joepier54985 ай бұрын
Great video and concise explanation.
@Jason-qe4tp9 ай бұрын
Hey Mike, I need help with zone damper troubleshooting and conversion guns troubleshooting and repairs....If you could help me out, I would greatly appreciate it. You explain things great and I retain it easily. Thanks for that seriously
@JerseyMikeHVAC9 ай бұрын
Conversion guns?
@Jason-qe4tp9 ай бұрын
@JerseyMikeHVAC Riello and Carlin oil to gas conversion gun. And i saw video on zone dampers too, it helped me out too, but still need help on some of the older ones. Thanks for responding your the man!
@danherring56762 ай бұрын
Excellent! Thanks a lot for that. Really clears up a lot of specifics.
@jasonjokiel71885 ай бұрын
Thank you !!!
@jakekostogiannis2 ай бұрын
This guy did a great job. More people need to dumb it down like this for us guys tryna learn. If you explain it like your talking to an engineer people wil not retain the information. Boilers and hydronics usually go way over my head but this made it simpler to understand. 👍
@JohnDoe-ej1lw9 ай бұрын
Big thanks mike for explaining everything in a simple understandable way... ... love your channel 🤙
@JerseyMikeHVAC9 ай бұрын
I appreciate that!
@jdogar19 ай бұрын
i worked as a plant operator for about 10 years. I used to get thoughts like this while plant is running itself...
@JerseyMikeHVAC9 ай бұрын
Power plant? I used to run a coal fired supercritical and later a combined cycle. Impressive how these things work.
@jdogar19 ай бұрын
@@JerseyMikeHVAC No at oilsands refinery. At fort mcmurray AB. Also i worked at Data Centres. Are you in from Canada or USA? Yes its is impressive...
@JerseyMikeHVAC9 ай бұрын
USA
@eddieroman36299 ай бұрын
thanks im a diy and that was alot of info i learned
@JerseyMikeHVAC9 ай бұрын
Glad I could help
@jdogar19 ай бұрын
Interesting Mike. thinking at its Finest...
@brandoncoffee80449 ай бұрын
Thanks Mike. This really helped me understand those close spaced Tee setups.
@JerseyMikeHVAC9 ай бұрын
Awesome. Glad it helped you out.
@brandoncoffee80449 ай бұрын
Is this method used only on larger homes with a lot of piping, or can it be used on smaller houses with very little piping as well??
@JerseyMikeHVAC9 ай бұрын
It's always on larger, multi-zone systems, but not exclusive to it. This design can be applied to any circumstance and often is, as the alternative requires very detailed design skills that are not so common.
@mattkaramccarthy6778 ай бұрын
@@JerseyMikeHVAC perfect answer right there. I know few contractors that could actually compute the correct pressure drops and pipe size for a direct flow system. Even explaining residual head for the internal pump is a struggle most days.