You should have explained what setting each screw is for.
@samuelmanthi54883 жыл бұрын
Hi. What might be the problem when my condor RU3 is always vibrating and i have installed a 3 phase stabilizer and set it at 405 volts, can i bypass it!!??
@paulmcgeoch26036 жыл бұрын
yeh its just that ive already got the mdr3 and cant find how to wire to 230v
@mannycastellanos62736 жыл бұрын
Thank you for your reply. It turned out to be my unloader valve.
@adamdiaz8442 Жыл бұрын
I have installed this on my 10hp at the 16amps setting but it just keeps tripping
@duncanrogers Жыл бұрын
Hi Adam, We recommend a 20-24Amp pressure switch for a 10HP compressor. Kind regards
@chriseller64026 жыл бұрын
can u set a 15 psi Differential say 110 to 125 psi
@andrewrogers99066 жыл бұрын
Yes, the differential on the mdr3 is adjustable. If the set cut in pressure is 3 bar the cut out pressure can be set anywhere between 4 and 7 bar so 3-4 bar is your 15psi.
@chriseller64026 жыл бұрын
@@andrewrogers9906 3 Bar is only 43psi i need 110 cut in to 125 psi
@paulmcgeoch26036 жыл бұрын
how would u wire this for single phase uk
@andrewrogers99066 жыл бұрын
You would normally use the MDR1 for single phase - see kzbin.info/www/bejne/qpzYqWlpqq9gqpo or www.airlines-pneumatics.co.uk/pneumatics/air-compressors-and-dryers/compressor-pressure-switches/condor-mdr1-compressor-pressure-switch/S020122
@frederic69982 жыл бұрын
I have it installed on my Worthington creyssensac DNX5300
@MsHomer007 Жыл бұрын
как отрегулировать нижний предел давления
@duncanrogers Жыл бұрын
Translated, the question was "how to adjust the lower pressure limit?" The cut in and cut out pressure can be set by turning the collaboration screw as shown in the video.
@electromanolin5 жыл бұрын
Thank you so much for this video
@mannycastellanos62736 жыл бұрын
Hi. Why does my pressure switch leak air after it cuts off
@andrewrogers99066 жыл бұрын
On a normal piston compressor there is a pipe from the compressor to a non return valve which is fitted to the receiver. When the compressor stops the unloader valve on the pressure switch vents the air in this pipe so that when the compressor starts next time it is not working against pressure. Therefore you will normally get an air exhaust noise each time the compressor stops but that should cease directly. If the non return valve on the receiver becomes faulty then air can leak from the receiver and out through the unloader on the pressure switch. This often leads to a call reporting a leaking pressure switch - always the first thing to check then is the non return valve. This non return valve can be subject to very high temperatures and has a seal which should replaced on a routine servicing basis.
@matseriksson62285 жыл бұрын
have the same problem is there some pics of the service routine on the replacing the seal ???
@paulmcgeoch26036 жыл бұрын
how would u wire this for single phase uk
@frederic69982 жыл бұрын
first line you enter with neutral, second one you enter with phase then you put a wire from the exit of that phase and put it on the entry of the 3rd line, so that now you have 2 exit availlable, one for neutral and one for phase.