Connection Design Overview - Part 3: RAM Connection Standalone || Design option, Report, Drawing

  Рет қаралды 919

Surojit Ghosh

Surojit Ghosh

Күн бұрын

Пікірлер: 13
@Enfld1122
@Enfld1122 6 ай бұрын
Make video on dynamic seismic analysis/non-linear time history analysis along with theoretical concepts.
@okeomaobedience7357
@okeomaobedience7357 6 ай бұрын
Thank so much surojit for always posting amazing contents. Please I have a question. What software is this in particular? Thanks a lot
@surojit_ghosh
@surojit_ghosh 6 ай бұрын
This is RAM Connection Standalone version, you can check part 1 of this series to know more about different modules -- kzbin.info/www/bejne/aZrNZ4OwpK-Yl80
@multazamfachri7165
@multazamfachri7165 6 ай бұрын
I think idea statica better than ram connection. More flexible . Staad cant desigm channel or angle shape as column
@prithwishkundu3818
@prithwishkundu3818 6 ай бұрын
Sir, is it possible to model any face to face angle connection in staad pro?
@surojit_ghosh
@surojit_ghosh 6 ай бұрын
No, it's not possible. Back to back angle or star angle arrangement is only possible for analysis and design.
@prithwishkundu3818
@prithwishkundu3818 6 ай бұрын
Ok..thanks you sir.
@waseemakram-kc6ne
@waseemakram-kc6ne 6 ай бұрын
Sir, Im trying to design connection for tapered beams and column for PEB structure in Ram connection Standalone..But in ram connection, there's no option for entering flange property value like thickness, width and also web thickness so how can be this issue resolved
@waseemakram-kc6ne
@waseemakram-kc6ne 6 ай бұрын
And sir I'm trying to design connection in integrated ram connection with Staad but while design it's giving an error that only American, Indian, Japanese sections are available.. No design for PEB sections
@surojit_ghosh
@surojit_ghosh 6 ай бұрын
In RAM Connection standalone, you can provide initial and final depth of the section along with section name. No separate option is available to provide section dimensions, as it is imported from the section database. If you are using custom/built-up section, add that section first in the database, then use that section for tapered beam and column.
@waseemakram-kc6ne
@waseemakram-kc6ne 6 ай бұрын
Thanks for your kind response.. Second question is that I try to use Integrated Ram with Staad but that's also giving an error by saying that only American, Japanese, Indian sections....are supported..Any solution for this
@surojit_ghosh
@surojit_ghosh 6 ай бұрын
I am not sure about the reason, which design code you are using? Also, you have modeled the tapered section properly in STAAD, right? Identification of any section including material is mandatory when Integrated connection design module is used.
@waseemakram-kc6ne
@waseemakram-kc6ne 6 ай бұрын
Dear Sir, I'm using AISC design Code.. Tapered section is assigned properly but I don't know why its giving this error
ЛУЧШИЙ ФОКУС + секрет! #shorts
00:12
Роман Magic
Рет қаралды 28 МЛН
Triple kill😹
00:18
GG Animation
Рет қаралды 18 МЛН
Walking on LEGO Be Like... #shorts #mingweirocks
00:41
mingweirocks
Рет қаралды 6 МЛН
Structural Analysis And Design Of A Four Storey Structure PART 1
10:37
Gold Gate Engineering
Рет қаралды 467
PEB Steel Connection Design in RAM connection
21:35
Torq
Рет қаралды 2,8 М.
SolidWorks Weldments Steel Structure
18:38
CAD CAM TUTORIAL BY MAHTABALAM
Рет қаралды 109 М.