1. Dg operator practical training kzbin.info/www/bejne/imiak41-i7p0jq8 2.Plc industrial automation free video tutorial course kzbin.info/www/bejne/npyUiIejgdqdqKM 3. Dse 7320 full course video tutorial kzbin.info/www/bejne/mKS9aWttar2ia5o 4. How to read Electrical Drawings Video tutorial kzbin.info/www/bejne/f3mrdIdqaNiXj68 5.how to bypass generator AVR kzbin.info/www/bejne/gKvYd3uBgtB-r6M 6. Three phase genrator excitation system video tutorial kzbin.info/www/bejne/j2bNpJt8rK12rM0
@shrirenukagenerators2 жыл бұрын
Ya Aa
@guillermorivera336311 ай бұрын
Good Day, thank you for sharing your experience in your videos. I would like to know more about the advantages that the DROOP potentiometer would give me to be able to put two Magnaplus 150 KW 480 volts 3 PH generators in parallel and synchronize it with the ESD5500E speed card. I have never used the Droop Potentiometer. I would appreciate if you explain to me how to adjust it and get both Generators to shear load
@jemskp3590 Жыл бұрын
Very good explain..and easy to understand thank you very much brother hoping success you chanel👍👍
@ELECTRICALPOWERGENERATION Жыл бұрын
Ur welcome bro
@valeryramirez10 ай бұрын
Thanks for the instructive video
@autoXpertSAL-wl8sg Жыл бұрын
Can you explain for us what is the difference between gain and droop and in which cases we have to adjust the gain and the droop?
@nengihart704810 ай бұрын
Good day, thanks for sharing this video. please can I reset over speed trip from the speed controller
@frankhernandez77002 жыл бұрын
High does Clarke fire pumps use this type of governors as well?
@rajeshmohan78815 ай бұрын
Please correct. In generator,speed is kept constant therefore actuator need not to increase rpm. RPM control is done thru excitation control.
@hidayathobbychannel6 ай бұрын
how to setting for overspeed sir? thanks
@RamBabu-ev9wl7 ай бұрын
Good job
@ELECTRICALPOWERGENERATION7 ай бұрын
Thanks
@moffatchabwera37472 жыл бұрын
Thank you for the presentation really helped, On the idle connection where do we connect this cable from there? PLEASE HELP.
@ArniAtlason2 жыл бұрын
You will connect Idle to G ground.
@НикитаХудяков-ы5э Жыл бұрын
To control the speed of the motor through the control panel (in my case agc150), do I need to connect to terminals "G" and "J"? Does the control panel adjust correctly if the control is "±10 V"? The old control panel was connected via IOM 220 and the speed controller was controlled by 0-20 mA
@aleksandartesic2838 Жыл бұрын
Does speed control unit needs to be connected to the DSE gen controler to work properly. Or not.
@yohannestegegne98658 ай бұрын
Tanks If mpu is fail it can staret engine
@rolandomendoza Жыл бұрын
Sir if LCD indicate 44volts only and gen under 1 indication what is cause and to solve thanks
@ELECTRICALPOWERGENERATION Жыл бұрын
Didn't understand 😕 what's are u asking
@kabelob.ramontsho5026 Жыл бұрын
Really informative, how can i rectify a generator loosing running power when under test run
@rahilmomin8246 Жыл бұрын
Sir ji video ko Hindi me bhi upload kar dijiye Hindi walo ka bhi bhala ho jaaye ga it's request sir please upload video in Hindi also
@ELECTRICALPOWERGENERATION Жыл бұрын
RAHIL MOMIN BHAI CHANNEL PER HER VIDEO KA HINDI MAI VIDEO AVAILABLE HAI
@edmundomoyo Жыл бұрын
Hi , I'm from angola africa , I want to know if you have a center where I can learn all these thing?
@ELECTRICALPOWERGENERATION Жыл бұрын
We offer one to one online training
@libertymz63807 ай бұрын
@DieselGeneratortraining can I have your email
@richieuntaran85302 жыл бұрын
Hi sir gd day how are you, sir if dse 7320 controller how to connect the idle speed, i noticed if i start generator like cummins 30seconds idle run after the engine stable around 1800 rpm, thanks sir
@geoffreyjahooksiraba77048 ай бұрын
I am working on a Cummins 80kVA diesel generator with PCC1302 controller, is there any possibility to disable the MPU on the controller and run the Genset? The fuel injector pump is mechanical.
@manuluvunga32588 ай бұрын
Hi bro ! yes i have a question on G-J terminal: how the external potentiometer can be connected between control panel and the speed controller?
@MdrokonUddin-vl3pe6 ай бұрын
Tanks
@muemamunyao33057 ай бұрын
Can I connect the ESD5500E USING CONTROLLER 702
@pizzarotettey9404 Жыл бұрын
When the engine is starting how many voltage do you get from the actuator
@eggycoolteknik5897 Жыл бұрын
Good job broo
@BataDonason-ls4wp Жыл бұрын
Thanks very much sir I really love it and understand but own is engine is steaming very high
@abdelkahardjarit3095 Жыл бұрын
Thanks
@hermantoofa18682 жыл бұрын
Hi bro ,what are the exact values to find on the pick up and actuator.i have à problem on my volvo genset TAD 740. Frequency drop after 4h
@ELECTRICALPOWERGENERATION2 жыл бұрын
It's depends on every manufacturer
@hermantoofa18682 жыл бұрын
@@ELECTRICALPOWERGENERATION can you explain me how to fix speed this speed controller
@charlesfleming76 Жыл бұрын
Hello .I run a diesel welder generator before I start welding I have to rev and leave the engine reved up for hours when welding. Will this speed control do to let the engine down to ticking over when not welding and when start welding it would rev back up
@ImranAli222224 ай бұрын
Aoa, Sir Meray pass aik Doosan 600KVA DG hae wo 3,4 hrs k bad load pe hunting karta hae,main ne diesel line b check ki hae,fuel pump,fuel filter, air filter,automizer b change kiay haen Actuator b change kia hae, Governor Card ESD5500e b change kia hae phir b hunting khatam nai hui,even governor card se Gain, Stability se setting b kar k dekha but issue still persist, rather than AVR b check kia ok hae voltage b stable haen Mazid koi solution hae to Bata dein
@ELECTRICALPOWERGENERATION4 ай бұрын
Ws load kitnay percent per hunting karta hai , use original governor card not Chinese n also actuator coil heat honay k baad bhe aisa dekha gaya hai
@ELECTRICALPOWERGENERATION4 ай бұрын
Doosan ka original governor card laga ain digital model Jo aj kal araha hai
@ImranAli222224 ай бұрын
@@ELECTRICALPOWERGENERATION Sir 50-60% load pe karta hae aur actuator coil b change ki hae Even Doosan ka original card DGC2007 b use kar k dekha hae
@ImranAli222224 ай бұрын
@@ELECTRICALPOWERGENERATION Ok sir thanks trying for digital card
@ELECTRICALPOWERGENERATION4 ай бұрын
What type of load is connected with generator try to check generator with resistive load bank
@jorgegonzalezv61802 жыл бұрын
Thanks a lot for this information my friend. I have the same governator. The engine speed of my generator is under 1800rpm. How can I give more speed. Thanks a lot.
@metchemmanuelmetch24722 жыл бұрын
That is good discorvry for to day to allowed my know the fonction of item.
@anggadwisetiawan64858 ай бұрын
Good evening sir, If the terminal A and B no have output voltage is this speed controller damage?
@rolandomendoza Жыл бұрын
If voltage appeal in LCD 40volts how to check or adjust low voltage sir
@misiskongtopakin6662 жыл бұрын
Hi sir, speed controller have fuse? Thanks
@ELECTRICALPOWERGENERATION2 жыл бұрын
No inbuilt fuse
@FredSichilima8 ай бұрын
The speed of my diesel generator is only going up to 1030rpm. This started after battery exploded . how do I increase the speed to 1500rpm.
@malikjamal98572 жыл бұрын
nice
@victoresolorio2342 жыл бұрын
Donde lo puedo comprar Control electronica Actuador pick up
@muhammadmehmood35152 жыл бұрын
Aoa nice but you have used their language in urdu. due to unknown person understand here.
@ELECTRICALPOWERGENERATION2 жыл бұрын
Inshallah next video isi topic per urdu mai hogeee
@ferdosbilaok5297 Жыл бұрын
Morning sir my name is ferdo my cummins 50 KVA generator I start it stops what is the problem please
@vedparkashchoudahary1812 Жыл бұрын
Bhai M N P wire ka conection hoga .
@rolandomendoza Жыл бұрын
How to adjust under voltage
@Doguiles.markruado Жыл бұрын
My friends may generator what is the problem this unit is no more power only 1800rpm only..if drive vibro hummer no incrising rpm..what is the problem my friend?.. thank you..
@rolandomendoza Жыл бұрын
44 voltage applecd
@rolandomendoza Жыл бұрын
How to adjust low voltage just only 40440
@gacgovernorsamericacorp1383 Жыл бұрын
The installed controller is a real GAC controller. The on on the bench you are looking at is a FAKE. Understand that although these are well explained how to videos - you are showing COUNTERFEIT products that are not going to work as well as the real GAC product.
@ELECTRICALPOWERGENERATION Жыл бұрын
Thanks for comment actually the purposes of the video is to show the basics and use of equipment we are not promoting any product for any inquiries please contact us via email : muzammiloger@hotmail.com