Hello friends this a reupload as I missed some parts. I believe showing correct and legit content is most important therefore I :have corrected and uploaded again for you guys. It is from 4:53 to 7:32. Thanks for watching. Love u all.
@kaakib88413 жыл бұрын
Sir Floor to floor height... Inner to inner distance lenge na?
@kaakib88413 жыл бұрын
Aapne plinth k top se slab ka top liya huwa hai
@azharnalbandh40293 жыл бұрын
@@kaakib8841 in to in floor to ceiling ho jayga, think about it
@anuragkhati45472 жыл бұрын
Sir if bars are of different dia then how do we adjust the cutting length
@vitthalpatil19742 жыл бұрын
column size is 350mm*2750mm. 34 bars of 20mm dia are vertical bars . cover is 75mm. Stirups bars are of 8mm dia. Master ring is easy to calculate but i m having problems with link bars. So plz tell me how to calculate Cutting length of link bars in column. There are 3 rings in which 4 bars are set i.e 12 vertical bars are in 3 rings and 3 vertical bars are in one ring. Total 15 and Master ring includes 2 vertical bars . Total 17 and similarly 17 bars on others sides.
@hz82004 жыл бұрын
Thanks sir..ap sab Kuch practically samjhate hoo. Jo koi aur KZbinrs Nahi batatae
@RajUp-l1c10 ай бұрын
Thank you thank you you just cleared my doubt since 4 years
@HammadSherwani-q5n Жыл бұрын
Perfectly explained❤
@yasirzhari25234 жыл бұрын
Best channel for civil engineers
@sarthakmohapatra37384 жыл бұрын
Excellent video sir. All of ur videos r different from the rest of the KZbin videos done by other people. Although there r tons of videos on finding out CL of column, but ur videos r always on the edge. Thnx
@EverythingCivil4 жыл бұрын
Thank u so much Sarthak. This really means a lot. Keep supporting ❤️
@pavush3264 жыл бұрын
One of the top quality ...video with superb detailing ...🙏
@EverythingCivil4 жыл бұрын
Thanks a ton
@rayansawant82884 жыл бұрын
Very usefull video for Civil Engineers!!!!
@pradeepkumaryadav38594 жыл бұрын
Great sir Crystal clear explanation sir. Learning can be there in 4 to 5 minutes video as others do , but urs is excellent sir , complete details u hv given sir Thanks u so much . Abhi aap shuttering pe video laye sir making se lekr checking takkk
@EverythingCivil4 жыл бұрын
Column shuttering pe next video
@avdheshbhatt2290 Жыл бұрын
very very helpfull video sir
@khushalharne52324 жыл бұрын
First view Bhai 👌👌 Nice Information
@EverythingCivil4 жыл бұрын
Thanks brother..keep supporting ❤️ U people are everything for me.
@TOP10-z5k8s Жыл бұрын
Bro slab to slab distance ya beam k depth minus Krna hai ??
@dulhapur3 жыл бұрын
For finding A zone and B zone in coloumn only two floor beams are considered,is not lintel tie beam required to be considered?
@NileshKumar-rv3bk2 жыл бұрын
51d = 51*16= 816 mm hoga . Par apne 306 liya h. In case Mera development length Ld middle portion se jayad ho jayega to kya karenge . Jaise Floor height 3 m h Mera dia of bar 20 mm h aur Ld = 51*20 = 1020 mm then Mera overlapping support side me chala jayega . Is case me kya karenge
@deoraobankar82597 ай бұрын
Thanks i understand.
@anuragkhati45474 жыл бұрын
Sir 12mt steel ko provide kr saktey hai ek hi length m pura ??
@EverythingCivil4 жыл бұрын
Haan agar apki puri cutting length lap wagera mila ke 12m ke andar arahi hai to kar sakte ho aap.
@anuragkhati45474 жыл бұрын
Thnx
@modassariqbal3064 жыл бұрын
Thnku so much sir!!
@EverythingCivil4 жыл бұрын
Most welcome
@homeplan3532 Жыл бұрын
Sir mere column ke sariye plinth beem se 3.6 & 4feet height hai to mujhe ab lapping ke liye ab sariye ke cutting height rakhni chahiye
@modassariqbal3064 жыл бұрын
Sir agr hamra Design mix me OPC 53 cement use kiya gya but kya me PPC cement used kr sakta hu column concrete k liye OPC 53 ki jagej p....kya strength p column k kuch farak parta hai kya
@EverythingCivil4 жыл бұрын
Nahi bilkul nahi. PPC cement me pozzolona material mix hota hai to uski strength OPC 53 se kam ayegi aur agar cement ki strength kam ayi to concrete ki bhi kam ayegi..agar ap chaho to design mix me flyash add kar sakte ho usse cement ka consumption kam ho jayega. PPC use karne se pehle uski strength check karo kitni aarahi hai agar opc53 jitni hai to it's ok..lekin yaad rakhna initial strength 70% bohot late ati hai PPC ki.
@anuragkhati45474 жыл бұрын
Sir BBS site par hi calculate krna pdta hai kya ??
@EverythingCivil4 жыл бұрын
Haa VFC drawing ane ke bad banta hai kaam shuru karne se pehle. Fitter ko cutting length dena padta hai cutting bending ke liye.
@anuragkhati45474 жыл бұрын
Bada project ho to usme kaise site p ho paeyga itni calculation ??
@EverythingCivil4 жыл бұрын
Badi site hogi to unka ek alag dept hoga billing ya QS with special staff who are experienced in this. Usually contractor is responsible for making the BBbs and client certifies it.
@anuragkhati45474 жыл бұрын
Ohk thanx a lot sir
@deepakraja42 Жыл бұрын
Sir I had took 6 ft below ground for footing and 4,5,6 ft steel above the ground . Now I overlapped the steel on ground floor and also given joggle. Sir mujhe g+4 banana hain kyonki maine ground floor pe lapping diya hain toh isse farak toh nai padega na. My all pillar size is 9*18 . Baaki main aur strong karne ke liye lapping ko welding Kara du kya. Pls answer sir
@nadeemsaiyed21862 жыл бұрын
Is 7 mt bar cutting length is allowable. As per rule it should be 4 mt only?
@EverythingCivil2 жыл бұрын
Why not dear.
@nileshsonawane3244 жыл бұрын
Shayad aap ki hi talash thi...bhai pls ek layout par details main ek video banao pls...
@EverythingCivil4 жыл бұрын
Oh..kis chiz ka layout.
@armyofficermanishsharma50394 жыл бұрын
Happy Engineers day brother
@EverythingCivil4 жыл бұрын
Happy Engineers day brother.🙌
@AjitSk21 Жыл бұрын
We have taken Tue beam at bout 5ft from footing and pn above of tie beam we have taken plinth bem of 5ft ... But due to improper planing at start we are getting lap joint between Tie bem and plinth beam .. is that allowed??
@raviraj96k742 жыл бұрын
51 d for 16mm bar =816
@souravbhandari73483 жыл бұрын
please make a video on multiple beams bbs
@hanumanthubellam669111 ай бұрын
How to take lap points
@aryaman4068 Жыл бұрын
Bend deduction???? One 90⁰ bend -2d?????
@amitkumarsah94353 жыл бұрын
isnt that bent up portion is called staggered portion or staggered and lapped portion mean the same?
@EverythingCivil3 жыл бұрын
Yes but staggered lapping means not all the lap should come at same levels.
@vivekborse27903 жыл бұрын
51 x 16=816 mm
@AshishKumar-mv8dm9 ай бұрын
51d= 51x16= 816mm how did you consider 306mm
@faizmalik31872 жыл бұрын
Gokani consultant I m also working on gokani r. C. C. Drawing
@ron49283 жыл бұрын
So there are 5 staggered and 5 non staggered bar in column
@themimic-chetanubale1603 Жыл бұрын
Slab thickness kyo nahi pakada
@Kumar-kf3cg3 жыл бұрын
Pleased provide bridge pile bbs
@sarojchhotray8287 Жыл бұрын
51*16=306???
@themimic-chetanubale1603 Жыл бұрын
😂
@kapilrana5756 Жыл бұрын
o.306 kaise agya jab stageered apka 806 hai to
@ankursinghsingh7295 ай бұрын
Bhai aapne Ldt ka calculation galat kiya hai 51x16= 816mm aayega na ki 306
@ROXY-zm6dd Жыл бұрын
L bar ka length consider karna bhool gaye aap😊
@shabeebali97423 жыл бұрын
Can you send the PDF file
@pranayalte41933 жыл бұрын
51d= 16×51=816 then how you got 306?
@EverythingCivil3 жыл бұрын
It was calculation error. Hope u understand. 😁
@dulhapur3 жыл бұрын
Clear Height between plinth beam top and roof beam bottom-11 feets Zone-A-11/4=33 inches Zone-B-11*12-66=132 -66=66 inches There are 6 bars 16mm@4,12mm@2 At zone B top- 2 no of lappings At zone B middle(30 inch below top lapping points)-3 no of lapping At Zone B bottom (30 inch below middle lap point)-1 lapping Whether the above arrangement is allowble? Whether lintel tie beam can be provided any zone? What if lintel tie beam falls on zone-A top area?
@soumenghosh67434 жыл бұрын
306 nehi 816 hoga
@EverythingCivil4 жыл бұрын
At what time stamp?
@soumenghosh67434 жыл бұрын
51*16=816 mm
@soumenghosh67434 жыл бұрын
@@EverythingCivil 51*16=816 mm
@EverythingCivil4 жыл бұрын
Yes error hogaya waha..but imp ye hai ke waha lap length lena hai...jo har kisi project me alag hota hai thoda thoda.
@mdfaiyazmiyan79592 жыл бұрын
Overlapping 51×d, 51×16=816 hota hai. App ne bola 306 kaise hota hai
@EverythingCivil2 жыл бұрын
I was calculating live. It was a calculation error. Please understand the concept.
@shabeebali97423 жыл бұрын
Ld is incorrect , 51d , 51*16 =816mm= 81 cm
@EverythingCivil3 жыл бұрын
Yes it was small error in calculating.
@mrjdtechcorner57833 жыл бұрын
Calculations me error he
@dilipdebnath49292 жыл бұрын
51d=51x16=816m=0.816 mt .I think this is the correct calculation .you have shown this as 306 mm=0.306 mt. This totaly wrong.
@pranavnaxane2252 Жыл бұрын
Wrong:-Check development length. 51*16=816mm.
@jitendraalshi6075 Жыл бұрын
U made calculation wrong I.e. 51 x d(16)= 816mm but you consider it as 316mm .
@cricketreview9037 Жыл бұрын
Only 2 zone
@onlymemes78422 жыл бұрын
lap legth galat li he
@balkrushnapatil2242 Жыл бұрын
51×16=816 hota hai 306 nahi
@ashwins14852 жыл бұрын
51*16=816
@Rajana89 Жыл бұрын
51d is not 306
@raviyadav72232 жыл бұрын
Sir isme jo 51d bola hai uska calculation 306 kaise hai 51×16= 816