Daikin ac vacuum kaise kare l Ac me vacuum kaise lagaye l ac vacuum kaise karte hain

  Рет қаралды 45,931

Raj ac tech

Raj ac tech

Күн бұрын

Пікірлер: 98
@rohitpaliwal1387
@rohitpaliwal1387 8 ай бұрын
Meter was on zero, what about the air in black pipe.
@shakirhusaain4322
@shakirhusaain4322 Жыл бұрын
Bhai apne charging line se air release nhi kiya aese me moisture ho sakta unit me
@rajactech
@rajactech Жыл бұрын
Bhai charging line se air tb nikalte hai jab vacuum nhi krrte hai us waqt okay.... Abhi is ac me maine vacuum krr rakha hai flashing krrne ki zaroorat nhi hai
@AliAbbas-pf7qe
@AliAbbas-pf7qe Жыл бұрын
ac mei gas r 22 ho r32 r410 ho takika sirf ek by wait charge karo any season jitne ac pr likhe h vacuum karke by pressure ac chala kar bilkul nahi
@odiapuojitu4244
@odiapuojitu4244 24 күн бұрын
Voltas inverter AC ka compressor 3 .4 hours chal na ka bata Banda kiy heraya sir
@rajactech
@rajactech 24 күн бұрын
@@odiapuojitu4244 inverter ac ka compressor band nhi hota hai uska speed kaam ho jata hai bs or agr room temperature match ho jaega tabhi off hoga
@subhashisdas1603
@subhashisdas1603 Жыл бұрын
Video k 1st me apne jo pressure release kiya wo keya outdoor ka purana gas tha?? Neya lia ac me only vacuum karna hota he??
@rajactech
@rajactech Жыл бұрын
1st me jo Pressure maine release kiya wo maine alag se pressure daal rakha tha...... Leak test karne ke lea..... Islea jab gas fill krrna hota hai to jo machine me pressure hota hai use release krrna hi hota hai.... Uske baad vacuum krrke gas charge krna hota hai
@pintunisahoo9442
@pintunisahoo9442 Жыл бұрын
Mene v ek Daikin ka non inverter AC liya hoon 15 din ho geya he lekin technician ne vaccum nehin Kiya he lekin ac chill jyada nehin ho raha he aur 24 degree temprature set karta hoon to room jyada thanda nehin ho raha he per compressor cutoff ho jata he please suggest me
@rajactech
@rajactech Жыл бұрын
Aap ye check karen ki jab ac ka compressor trip ho jata hai us waqt aapka room temperature kya rehta hah......... Agr room temperature bhi 24 degree me aane ke baad compressor cutoff hota hai tb to aap ka ac thik hai.......... Or agr room temperature 24 degree se zyaada hua yani ke 26,27ya 28 degree me hi cutoff hota hai to aapke ac me gas kam hai.......... Is condition me aapko apni ac ka gas check krwana hoga
@AnujKumar-is8jf
@AnujKumar-is8jf 8 ай бұрын
Sir maine daikin ka inverter ac liya hai.lekin technician ne vaccum nahi kiya ab mai kya karu sir smjh nahi aaraha
@rajactech
@rajactech 8 ай бұрын
Koi problem nhi hai qke installation ke wakt koi bhi technician ke pass vacuum machine nhi hota wo self vaccum krr dete hai uske baad hi gas open krrte hai......
@NadeemAli-y1q
@NadeemAli-y1q 5 ай бұрын
ویکیوم کرتے وقت ہلکی کھلی ہونی چاہیے کیا
@xcvgamerxyy9685
@xcvgamerxyy9685 8 ай бұрын
Bro I bought ac 2 days ago they didn’t vacuum even I asked now can I vacuum after using or not
@rajactech
@rajactech 8 ай бұрын
If you have opened the AC gas then you will not have to vacuum. If you have not opened the AC gas then you will have to vacuum.
@xcvgamerxyy9685
@xcvgamerxyy9685 8 ай бұрын
Does it cause any problems for not opening
@FaridaartistMDvlogger
@FaridaartistMDvlogger 5 ай бұрын
Ac install kara but vaccum nahi kara....phirse vaccum kar saktey hai
@shonababu.1
@shonababu.1 7 ай бұрын
भाई वैक्यूम गैस डालने के बाद किया जाता है या फिर गैस खोलने से पहले किया जाता है ?
@rajactech
@rajactech 7 ай бұрын
Vaccuum gas kholne se pehle Or gas charge krrne se pehle vaccuum kiya jata hai
@anirbanhazra8053
@anirbanhazra8053 7 ай бұрын
I have Daikin 1.5 Ton 3 Star AC. Room size is 140 square feet. It takes 30 minutes to go from 36 degrees to 28 degrees at noon, but then it takes 3 hours to go from 26 degrees. I don't understand what the problem is.( Bahar ka Temperature 45 degree and Room temparature 40 rehta hain ). *Please help me and tell me how long it takes to change from 36 degrees to 26 degrees.*
@rajactech
@rajactech 7 ай бұрын
Check in ac gas for ac technician
@lakhankumarguptalpg4511
@lakhankumarguptalpg4511 10 ай бұрын
_29.9 ho jaiga vacuum complete hone par
@sagartiwari9079
@sagartiwari9079 6 ай бұрын
Bhaiya mere aaj hi gas dal wayi h mere technician ne purani gas ko hold krke vaccum kra tha unit ko phir new gas charging kr di h kya usne shi kiya hai
@rajactech
@rajactech 6 ай бұрын
Agar vaccuum indoor hua hai to ye process shi hai
@sagartiwari9079
@sagartiwari9079 6 ай бұрын
@@rajactech yes sir indor kiya tha
@rajactech
@rajactech 6 ай бұрын
Ok to wo technician aapka kaam accha kiya hai good work
@sagartiwari9079
@sagartiwari9079 6 ай бұрын
Sir kal gas charging kiya tha to kal to achi cooling kr rha tha par aaj esa lga ki kam cooling ho
@rockeeenayak1044
@rockeeenayak1044 7 ай бұрын
Sir..hamare AC ko vaccume nhi kiya.....bola..kuch nhi hga....kuch problem. hoga...kya
@rajactech
@rajactech 7 ай бұрын
Koi dikkat nhi hai
@amitkumarbeja3029
@amitkumarbeja3029 Жыл бұрын
New split AC non inverter jab installation hoga tab kiska vacuum hoga ? Indoor Unit ka hoga na ? Outdoor unit pe toh already gas fill hota hai toh vacuum nehi hoga ? Mujhe shop wale aur installation karne wale joh log aye the bola ki non inverter AC pe vacuum nehi hota hai only inverter AC pe hota hai vaccum. Please clarify mu doubts.
@sovonsen
@sovonsen Жыл бұрын
Vacuum sabhi type ke ac mein hota hai or mandatory hai vacuum karna, technician vacuum karna nahi chahte hai kyu pata nahi
@NadeemAli-y1q
@NadeemAli-y1q 5 ай бұрын
Vacuum krty waqt alki khuli honi chaia
@rajactech
@rajactech 5 ай бұрын
@@NadeemAli-y1q vacuum krte waqt Elenky bnd honi chaahie
@rashmivoicee
@rashmivoicee 8 ай бұрын
Isme 3 core wire ya 4 core wire, konsa lagta hai?
@rajactech
@rajactech 8 ай бұрын
Agr inverter ac hai to 4 core wire lagega
@PremKumargupta-jl4dw
@PremKumargupta-jl4dw Жыл бұрын
Great👍👍👍
@kratosspartan9125
@kratosspartan9125 10 ай бұрын
Bro aaj he install krwaya.. mera lg ka ac 4 min me vaccum hogya 0 k niche aa gy pura.. ky sahi hua?
@rajactech
@rajactech 10 ай бұрын
Perfect hai
@drharsh1325
@drharsh1325 9 ай бұрын
Gas fill krne me kya charge lega technician
@rajactech
@rajactech 9 ай бұрын
Har jagha ka alag alag rate hai... Ok mujhe nhi pta ke aapka location kya hai
@drharsh1325
@drharsh1325 9 ай бұрын
@@rajactech fir v approx kitna lega sir bihar patna
@rajactech
@rajactech 9 ай бұрын
3000
@lakhankumarguptalpg4511
@lakhankumarguptalpg4511 10 ай бұрын
Charging Haus Rong hai Blu hona chaheai red nhi hota h
@PankajKumar-jb4hv
@PankajKumar-jb4hv Жыл бұрын
Maine daikin ka inverter ac liya h lekin technician ne vaccume nhi kiya h usse compressor ya cooling par bad effect parega.
@rajactech
@rajactech Жыл бұрын
Koi dikkat nhi hogi
@manojpri2002
@manojpri2002 Жыл бұрын
Kya new ac installation me vaccue karna hota hai... Yaha wale mana karte hai.. Plz batana
@rajactech
@rajactech Жыл бұрын
Dekhea vacuum krrna to zaroori hai kuch log vacuum machine ka istemaal nhi krrte but wo self vacuum zaroor krrte hai
@manojpri2002
@manojpri2002 Жыл бұрын
@@rajactech Kya Self vaccum se Naya AC ke performance me kuch fark padega? Ya machine wala vaccum hi jaruri hai? Wese company ka kya rule hota hai
@zahidulislambd409
@zahidulislambd409 Жыл бұрын
No
@deepchand6605
@deepchand6605 Жыл бұрын
ਇਸ ਕੋ ਖੁਦ ਨਹੀਂ ਪਤਾ ਆਪ ਨੂੰ ਕੀ ਸਮਝਾਏਗਾ।
@kamaldeepsingh9131
@kamaldeepsingh9131 4 ай бұрын
What about purjing?
@IbrahimKhan-ld2fx
@IbrahimKhan-ld2fx Жыл бұрын
Back pressure 125 se130 psi se jyada nhi kre
@Owais_royal
@Owais_royal Жыл бұрын
Bhai aapki help chahiye ek me aapka subscriber huu bhai
@rajactech
@rajactech Жыл бұрын
Hnn bolea kya help chahea
@rajactech
@rajactech Жыл бұрын
Hnn bolea kya help chahea
@swagatadasbairagi545
@swagatadasbairagi545 8 ай бұрын
PLEASE HELP ME!!!!!!!! Mera ek LG AC ek mahine pehle installation karaya tha but us samay LG walo ne vaccum nahi kiya. Onke pas machine nahi tha. In future koi problem kya ho sakta hain? Please bataiye
@RupeshKumar-ci3on
@RupeshKumar-ci3on 8 ай бұрын
Bhai kio dikte nahi hogi gas refilling ke time vacuum zaroori ha new installation ke time nahi
@rajactech
@rajactech 8 ай бұрын
Koi problem nhi hoga..... Future me
@akashshirsat7030
@akashshirsat7030 Жыл бұрын
मैने new ac लिया daikin का लेकिन technician उसे vaccum नही किया कुछ प्रॉब्लेम आयेगा क्या
@rajactech
@rajactech Жыл бұрын
Nhi koi dikkat nhi hogi ...
@akashshirsat7030
@akashshirsat7030 Жыл бұрын
@@rajactech थँक्स भाई लेकिन बहोत से youtuber बोलते है नये ac को vaccum कारण compulsary है नाही तो बहोत दिक्कत आती है ये संच है क्या
@rajactech
@rajactech Жыл бұрын
@@akashshirsat7030 Aisi koi baat nhi hah prr jiske pass vacuum machines nhi hota wo technician self vacuum krrte hii hain pr coustomer ko is baat ka pta nhi hota hah...... Or hamare paas bhi agr kisi side ke lea vacuum machines nhi hote to humlog bhi self vacuum krke machine on krdete hai........ Thik hai
@akashshirsat7030
@akashshirsat7030 Жыл бұрын
@@rajactech thank you so much for your valueable feedback
@akashshirsat7030
@akashshirsat7030 Жыл бұрын
@@rajactech भाई और एक प्रश्न था मेरे इनडोअर से आऊटडोअर कि दुरी बहोत कम है तो technician ने मेरे कॉपर pipe को काटा तो कॉपर pipe कि लेन्थ कम हो गई है उसे कुछ प्रॉब्लेम आये गा क्या
@dubai.visit4126
@dubai.visit4126 Жыл бұрын
Good job🎉
@rajactech
@rajactech Жыл бұрын
Thnx
@tasarrufkhanbijnorwale3056
@tasarrufkhanbijnorwale3056 Жыл бұрын
Aap kaha kam karte ho
@rajactech
@rajactech Жыл бұрын
Raanchi Daikin me
@ransinghyadav5073
@ransinghyadav5073 6 ай бұрын
Bhai minus me to nhi आया kata
@rishabhgupta8743
@rishabhgupta8743 8 ай бұрын
Best
@rishabhgupta8743
@rishabhgupta8743 8 ай бұрын
Maine aaj ac install karaya to cooling nahi Hui....install karne wale na kaha ki R32 gas missing h, fir uske baad service Wale se baat karke bola ki kal dalunga gas....to kya ac lena chaiye ya waapis kardu??
@vinayrawat2299
@vinayrawat2299 8 ай бұрын
mene apne panasonic ka ac vacuum krwaya usne to 5 min. liya bs or videos mai log kehre 15-20 ya 30 min krna hai...ab kya bole kuch pta hi nahi tha
@rajactech
@rajactech 8 ай бұрын
Koi problem nhi hai agr vacuum -30 psi tk ho jata hai to 5 minuts me bhi koi dikkat nhi hai
@deepchand6605
@deepchand6605 Жыл бұрын
ਅਰੇ ਭਾਈ ਆਪ ਗ਼ਲਤ ਸਮਝਾ ਰਹੇ ਹੈ। ਆਪ ਨੇ ਜੌ ਪਾਈਪ ਲਾਈਨ ਉਸ ਵਿਚੋ ਹਵਾ ਨਹੀਂ ਕੱਢੀ,ਜੌ ਬਹੁਤ ਗ਼ਲਤ ਹੈ।
@rajactech
@rajactech Жыл бұрын
Hindi or English language only
@technicalknowledge476
@technicalknowledge476 10 ай бұрын
Are,bhai,tumne gas,charge karte time charging line ko nhi khola thodi c air hoti h usme
@skamir5348
@skamir5348 Жыл бұрын
Thanks
@dubai.visit4126
@dubai.visit4126 Жыл бұрын
💛💛💛💛
@ramlalabiyar5795
@ramlalabiyar5795 Ай бұрын
😅
@samidulsekh5282
@samidulsekh5282 Жыл бұрын
Vi ❤
@aryan-9562
@aryan-9562 7 ай бұрын
Wrong process, rarely kisi ko proper vacuum ka technical knowledge hota hai, bas vacuum pump lagao aur hata do, bas iske alawa kuch nahi aata, black pipe ki air suck ho gayi unit mei,
@informationprovider5263
@informationprovider5263 Жыл бұрын
Single Stage vs Double Stage kaise pata kare. Technician aata hai aur bolta hai Double Stage hai 5 min me vacuum ho jayega 😑
@rajactech
@rajactech Жыл бұрын
Hmm km se km 15 minute to krrna hi chahea
@Abhishek-px4em
@Abhishek-px4em Жыл бұрын
Paise mat dena or sign bhi mat karna jabtak minimum 15 minute na kre
@mdmoon6790
@mdmoon6790 Жыл бұрын
Kam se kam 30min kiya jana chahiye
@mdmoon6790
@mdmoon6790 Жыл бұрын
-29.92 inchg psig low pressure gauge me dikhaye to sab thik h
@lathisolty8543
@lathisolty8543 10 ай бұрын
Bhai Tumara vacum pump konsa cumpani or price kithna
@AliBhai-qg5yo
@AliBhai-qg5yo Ай бұрын
R32
@SwetaSharma-mj2rq
@SwetaSharma-mj2rq 7 ай бұрын
Ye ek dhokhebaj hai jo apni biwi beti ka na hua wo kamina kiska hoga
@rajactech
@rajactech 6 ай бұрын
Ye aap kya bol rahe hai
@islammalik3463
@islammalik3463 Жыл бұрын
R32 back psi 110 .115 psi chalta h nahi pata to wrong video kiyu banate ho
@rajactech
@rajactech Жыл бұрын
R 32 back psi 110 , 115 hi hota hai bhai 120 pai mai bol diya to kya glt ho gya aap kitne dinse is field me ho..... Kya 5 pai zyaada ya kam hone se kya dikkat hoti hai..... Aap mujhe bataen mujhe bhi kuch jaanne sikhne ko milega..
@Cartoondhamaka051
@Cartoondhamaka051 9 ай бұрын
Bhai 120 se 125 hi hona chaiye isse कैंप्रेसर badya kaam karega🎉
@mdzubair4101
@mdzubair4101 8 ай бұрын
​@@rajactechjayada.high.temp..bahar.rahega.to.125rhega.we.chutiya.h.usko.tota.ki.tarah.rata.huaa.h.dimag.nahi.h
When you have a very capricious child 😂😘👍
00:16
Like Asiya
Рет қаралды 18 МЛН
Try this prank with your friends 😂 @karina-kola
00:18
Andrey Grechka
Рет қаралды 9 МЛН
Cat mode and a glass of water #family #humor #fun
00:22
Kotiki_Z
Рет қаралды 42 МЛН
Daikin Split AC Installation | New AC Installation | Ac Technician95
10:46
Brazing Flaring And Pipe Bending Practical In Hindi.
46:07
Kareem technical mind
Рет қаралды 20 М.