Daikin inverter | air conditioner Thermistor Failure Symptom

  Рет қаралды 24,230

Bon Mj

Bon Mj

2 жыл бұрын

Brand : Daikin
model : MKS80QVM
ERROR : No error
Symptom: Running after 45minutes,Fcu auto off and auto on back,outdoor LED 1 & 2 light up.
Cause : Thermistor failure Symptom,thermistor short circuit.
#bonmj #daikin #inverter

Пікірлер: 108
@Techhvac
@Techhvac 2 ай бұрын
Sir .Bon Mj Your technical Video's very useful for technician. Great job Thank you so much 🙏🇶🇦
@BonMj
@BonMj Ай бұрын
It's my pleasure
@vladimirmakhney5407
@vladimirmakhney5407 2 жыл бұрын
Hello. A very good tip, I'm sure many technicians didn't even know about it
@BonMj
@BonMj 2 жыл бұрын
Thanks
@JDT738126
@JDT738126 2 жыл бұрын
Bon your videos are excellent! Thank you
@BonMj
@BonMj 2 жыл бұрын
Thanks
@robinsonguanzon8092
@robinsonguanzon8092 2 жыл бұрын
Thanks Sir Bon Mj ❤️ A big help to us technician, A far areas and urban areas..🙏🙏🙏
@BonMj
@BonMj 2 жыл бұрын
Welcome
@Achabab
@Achabab 2 жыл бұрын
I never find this problem before😂😂😂, first time some one share this information in KZbin. You are the best⭐⭐⭐⭐⭐
@BonMj
@BonMj 2 жыл бұрын
Thanks
@carlocurotto7555
@carlocurotto7555 2 жыл бұрын
That’s a great tip thank another fantastic video
@BonMj
@BonMj 2 жыл бұрын
Thanks bro🙏
@jagannath3839
@jagannath3839 2 жыл бұрын
This is very good helpful information thanx sir.
@BonMj
@BonMj 2 жыл бұрын
Thanks
@birin.6884
@birin.6884 2 жыл бұрын
Hey, thanks for everything. explain his picture and I'm good.
@estanislauboavidabelo4975
@estanislauboavidabelo4975 2 жыл бұрын
thank you, please continue to upload the video.
@BonMj
@BonMj 2 жыл бұрын
Thanks bro
@februaryoakkar938
@februaryoakkar938 2 жыл бұрын
Thank you sir
@Blueblurr112
@Blueblurr112 2 жыл бұрын
Great video thank you.
@BonMj
@BonMj 2 жыл бұрын
Thanks
@alanwong2761
@alanwong2761 2 жыл бұрын
👏 bravo bro 👍
@linaung127
@linaung127 2 жыл бұрын
Hello sir, nice troubleshooting, thanks
@BonMj
@BonMj 2 жыл бұрын
Welcome
@narayanaya5519
@narayanaya5519 Жыл бұрын
Very useful information
@BonMj
@BonMj Жыл бұрын
Thanks
@arunramachandrana1025
@arunramachandrana1025 2 жыл бұрын
Very good information
@BonMj
@BonMj 2 жыл бұрын
Thanks
@khaidang8614
@khaidang8614 Жыл бұрын
@shreekanay698
@shreekanay698 2 жыл бұрын
Thanks Boss.
@BonMj
@BonMj 2 жыл бұрын
Thanks
@Didik-cq8wy
@Didik-cq8wy Жыл бұрын
Trimakasih bos
@BonMj
@BonMj Жыл бұрын
You Dari mana? Terima kasih banyak nonton video saya
@karimchiu7527
@karimchiu7527 Жыл бұрын
Thank Sir Bon
@BonMj
@BonMj Жыл бұрын
Welcome
@arafteknikac
@arafteknikac 2 жыл бұрын
Thank you so much
@BonMj
@BonMj 2 жыл бұрын
Thanks
@sarfarajshaikh4582
@sarfarajshaikh4582 2 жыл бұрын
Nice one bro
@BonMj
@BonMj 2 жыл бұрын
Thanks
@hafeezdaikin2517
@hafeezdaikin2517 2 жыл бұрын
Thank you boos 👍
@BonMj
@BonMj 2 жыл бұрын
Thanks
@aselajayasundara1669
@aselajayasundara1669 2 жыл бұрын
Thank you sir 🙏
@BonMj
@BonMj 2 жыл бұрын
Thanks🙏
@karaors8970
@karaors8970 2 жыл бұрын
Thank you bro
@BonMj
@BonMj 2 жыл бұрын
Thanks bro
@tabresztabu562
@tabresztabu562 2 жыл бұрын
Tq Boss 🙏
@BonMj
@BonMj 2 жыл бұрын
Thanks🙏
@mdtuhintalukder5012
@mdtuhintalukder5012 2 жыл бұрын
Thank you....
@BonMj
@BonMj 2 жыл бұрын
Thanks
@winmaung4558
@winmaung4558 Жыл бұрын
Thank sir
@BonMj
@BonMj Жыл бұрын
Welcome
@jamestan7901
@jamestan7901 2 жыл бұрын
👍 👍 👍
@JDT738126
@JDT738126 2 жыл бұрын
Hi Bon, could you please provide a source for many of the common manufacturers thermistor resistance/temperature values? I cannot find any for the LG brand.
@user-vz6mu7iu7j
@user-vz6mu7iu7j Жыл бұрын
hi sir im p paul kolkata i lick you video
@peramaraj2763
@peramaraj2763 10 ай бұрын
Normally daikin compressor discharge thermistor range 13 to 15 kilohms right ?
@antoinetuyongo6527
@antoinetuyongo6527 2 жыл бұрын
Bonjour , comment je pourrais avoir la version française
@MrRandyj72
@MrRandyj72 2 жыл бұрын
That would be hard to find on the system unless its in cooling mode developing condensation at the time you are checking. Did the error code send you in the direction to check the thermistors? Last question did you full change the harness or just dry and seal the bad thermistor?
@BonMj
@BonMj 2 жыл бұрын
Just happen after running 45minutes. Only outdoor LED 1&2 on when stop running,indoor auto off and will auto on back after for awhile. We replace the new harness.
@Achabab
@Achabab 2 жыл бұрын
@@BonMj thank you share your knowledge 🙏🙏🙏god bless you
@BonMj
@BonMj 2 жыл бұрын
@@Achabab welcome
@alembattlerealmsgamefowl6631
@alembattlerealmsgamefowl6631 3 ай бұрын
sir inverter daikin 1.5hp ,indoor fan motor stay in low speed what maybe the reason o the problem ? even we changes to high speed in the remote fan speed still low,thanks for the reply
@BonMj
@BonMj 3 ай бұрын
Any coil choke
@azadabduellahal8116
@azadabduellahal8116 Жыл бұрын
Same can happen Mitsubishi system
@zse0118
@zse0118 Жыл бұрын
Hi Sir! What's the reason you put the thermistor in the water and than you checked the countinity again?
@BonMj
@BonMj Жыл бұрын
Put in the water just show the thermistor is short circuit when water go in to the parts. When the thermistor locate at suction pipe,the water will go into the parts after gas pipe condensation.
@zse0118
@zse0118 Жыл бұрын
@@BonMj Thank you so much for your answer.
@ThesecretS_a_n_3_1
@ThesecretS_a_n_3_1 2 ай бұрын
Daikin Indoor fan motor no running a6 alarm coming I replace indoor motor and indoor PCB board also but still have a6 alarm ? What is problem
@BonMj
@BonMj 2 ай бұрын
Check thermistor
@arasanairconsolution4u9
@arasanairconsolution4u9 Жыл бұрын
Hai sir ,vrv 3 Daikin system one outdoor 3 indoor ,all running good but , standard compressor Haven't run even one FCU haven't achieve room required temperature.please advise
@BonMj
@BonMj Жыл бұрын
May be already by pass. Check mode2
@peramaraj2763
@peramaraj2763 10 ай бұрын
​@@BonMjalready bypass how to find ? Bro
@janshaw5472
@janshaw5472 2 жыл бұрын
这种情况好难被发现!感谢老师!contiuniry中文是什么?
@BonMj
@BonMj 2 жыл бұрын
谢谢你。去了两次才发现
@BonMj
@BonMj 2 жыл бұрын
Continuity 是联系的,比如wire用meter 量continuity 。
@errantpmd3765
@errantpmd3765 Жыл бұрын
Sir. My aircon.. cut in compressor n fan for 30min for 3 room. Is it thermistor of outdoor? I saw your ismike series, u change the indoor thermistor... May I know if is the same logic? Mine are toshiba
@BonMj
@BonMj Жыл бұрын
What is your setting temperature
@errantpmd3765
@errantpmd3765 Жыл бұрын
@@BonMj sir.. even in the lowest also the same.
@errantpmd3765
@errantpmd3765 Жыл бұрын
@@BonMj correction sir. Is 30sec..not min.
@BonMj
@BonMj Жыл бұрын
@@errantpmd3765 may be outdoor pcb problem
@errantpmd3765
@errantpmd3765 Жыл бұрын
@@BonMj sad.. :( Thought is some thermistor...
@randypatcho6051
@randypatcho6051 Жыл бұрын
How to apply your company sir
@narayanaya5519
@narayanaya5519 Жыл бұрын
If short thermistor what could happen PCB
@BonMj
@BonMj Жыл бұрын
For this case intermittent blinking, pcb ok.
@gothandaraj860
@gothandaraj860 2 жыл бұрын
Hi sir vrv 3 Daikin AC e2 error and E3 error how to make rectify
@BonMj
@BonMj 2 жыл бұрын
E2 may earth leakage E3 high pressure sensor/high pressure switch
@abidshirhatti6815
@abidshirhatti6815 2 жыл бұрын
Hi sir my wathsup no not going for comment
@ManojKumar-zu2yz
@ManojKumar-zu2yz Жыл бұрын
Sir daikin vrv3 modal rxyq12pry6 error code p4 Cheng master PCB
@govindarasugovindarasu7440
@govindarasugovindarasu7440 2 жыл бұрын
Hi sir I have problem is Diakin air conditioning vrv system celling saspanded units have the error UF this error what is the problem sir thanks
@BonMj
@BonMj 2 жыл бұрын
You change indoor pcb?
@govindarasugovindarasu7440
@govindarasugovindarasu7440 2 жыл бұрын
@@BonMj no sir
@BonMj
@BonMj 2 жыл бұрын
@@govindarasugovindarasu7440 check indoor all fcu voltage or pcb faulty
@mycountrymyvlog1
@mycountrymyvlog1 2 жыл бұрын
i need job i am air conditioning and refrigeration mechanic
@nagarajvenkat8476
@nagarajvenkat8476 2 жыл бұрын
Hi sir I have problem daikin package unit error E 32 how to rectify this problem sir
@BonMj
@BonMj 2 жыл бұрын
Check Compressor 1
@nagarajvenkat8476
@nagarajvenkat8476 2 жыл бұрын
Thanks sir
@azizullahkhanpathan2693
@azizullahkhanpathan2693 Жыл бұрын
Hello sir I am Aziz. I have a Daikin 1.5 ton inverter split AC. My AC is showing C3 error code. Can you please tell me what C3 error code is and how to solve it . Model no FTKZ50U
@BonMj
@BonMj Жыл бұрын
Try check i door thermistor. Actually this error is water level sensor problem
@azizullahkhanpathan2693
@azizullahkhanpathan2693 Жыл бұрын
Thank you for your reply sir 👍
@azizullahkhanpathan2693
@azizullahkhanpathan2693 Жыл бұрын
I will check
@azizullahkhanpathan2693
@azizullahkhanpathan2693 Жыл бұрын
@@BonMj Hello sir my AC is Daikin inverter split AC it is showing C3 error code will you please confirm what is the issue in it C3 means?????
@azizullahkhanpathan2693
@azizullahkhanpathan2693 Жыл бұрын
In the split AC water level sensor will be there ?????
THERMISTOR Operation and Testing! Inverter and Mini Split Training!
5:41
AC Service Tech LLC
Рет қаралды 109 М.
Playing hide and seek with my dog 🐶
00:25
Zach King
Рет қаралды 37 МЛН
Survive 100 Days In Nuclear Bunker, Win $500,000
32:21
MrBeast
Рет қаралды 104 МЛН
Smart Sigma Kid #funny #sigma #memes
00:26
CRAZY GREAPA
Рет қаралды 4,7 МЛН
Fast and Furious: New Zealand 🚗
00:29
How Ridiculous
Рет қаралды 45 МЛН
Daikin | How to rectify (error code J5)
7:29
Bon Mj
Рет қаралды 29 М.
Ремонт инверторного  кондиционера  Daikin
11:34
Быт-Мастер
Рет қаралды 8 М.
Ремонт сплит системы LG.
44:48
yanmaster
Рет қаралды 48 М.
How Air Conditioner Works And What We Have Inside
14:42
Electronoobs
Рет қаралды 363 М.
Diagnosing Daikin U0 Error
7:29
Mitch Attwood
Рет қаралды 53 М.
Daikin VRV3 | error E4 | LPS switch
8:43
Bon Mj
Рет қаралды 19 М.
Playing hide and seek with my dog 🐶
00:25
Zach King
Рет қаралды 37 МЛН