Defrost Board Diagnosing, and Replacement.

  Рет қаралды 14,749

HVAC GUY

HVAC GUY

Күн бұрын

Пікірлер: 19
@jeffweaver955
@jeffweaver955 Жыл бұрын
Close to helpful. Thanks anyways
@paulrodriguez8497
@paulrodriguez8497 27 күн бұрын
AC MAN is sloppy and safety,he did turn turn the fuse off at the AC unit and the house…
@paulrodriguez8497
@paulrodriguez8497 18 күн бұрын
Sloppy big time 🫢 😂😂🤣
@yodamanrulz176
@yodamanrulz176 Жыл бұрын
Pretty sloppy video. Curtis, come on man! More detail is paramount. Approach all as if we can’t read your mind. I’m a big fan, you have done much better. I would have to edit much more thoroughly. You are too cool dude. Kudos for your work, enthusiasm, and professionalism always. You are one of the best 😊😊
@aaronclark1599
@aaronclark1599 Жыл бұрын
I have a question, on my package unit heat pump I'm not getting 24 volts from the Yellow and Common wire going to the board, I have a new T-stat. What would cause this? My only guess is I have a broken wire.. What do you think?
@adamcraig1568
@adamcraig1568 3 жыл бұрын
Great video. Get a smaller nut driver 😂
@juliorodriguez8863
@juliorodriguez8863 2 жыл бұрын
EXCELLENT.!! Remember to wear gloves
@mikeconnole4375
@mikeconnole4375 Жыл бұрын
Defrost thermostat (sensor) and defrost board upgraded since it appears when the sensor was installed on new board via molex plug? I did not catch how the sensor was tested as it was assumed it was sensing it was frozen!
@zachosborne6577
@zachosborne6577 Жыл бұрын
I believe you ohm the sensor for proper resistance. Although if it is frozen and not defrosting but properly mounted it would be fair to surmise it is not sending the frozen coil.
@jjjames5089
@jjjames5089 3 жыл бұрын
Unsafe practices.
@TitaniumTurbine
@TitaniumTurbine 2 ай бұрын
3:51 specifically really irritated me. Holy shit, that’s the kind of safety precautions that land people in the hospital or in a coffin. 24 volts is NO JOKE.
@smallridertoo4463
@smallridertoo4463 2 жыл бұрын
dude just threw the cover on their plants
@coreyingram947
@coreyingram947 2 жыл бұрын
What was that that you changed with the jumper on the defrost control board? Just replaced one on my unit at home and set it like the old one at 50. Didn't know what the numbers were so didn't want to change anything. Thanks
@bstevens9831
@bstevens9831 Жыл бұрын
It's a pin to set how long it waits to go into defrost mode. There are usually several pins and the 50 is 50 minutes. Most likely Curtis set it for the shortest wait time.
@enticerusa
@enticerusa Жыл бұрын
So what terminals were you jumping with your screwdriver to make it go in to defrost..?
@Zuuuniga11
@Zuuuniga11 Жыл бұрын
The “speedup” or “test” terminals
@woodystokes1543
@woodystokes1543 9 ай бұрын
Nice 👍🏼 😊
@beau-beauthecharlieboy8098
@beau-beauthecharlieboy8098 2 жыл бұрын
Wrong wrong wrong
@raphaelwatson3927
@raphaelwatson3927 Жыл бұрын
great job
Troubleshooting a Bryant Defrost Board
12:55
John Jennings
Рет қаралды 22 М.
How To Test Defrost On A Heat Pump
8:20
HVAC GUY
Рет қаралды 15 М.
escape in roblox in real life
00:13
Kan Andrey
Рет қаралды 92 МЛН
А ВЫ ЛЮБИТЕ ШКОЛУ?? #shorts
00:20
Паша Осадчий
Рет қаралды 9 МЛН
💩Поу и Поулина ☠️МОЧАТ 😖Хмурых Тварей?!
00:34
Ной Анимация
Рет қаралды 2 МЛН
Learn Everything About Heat Pump Defrost
26:00
HVAC School
Рет қаралды 69 М.
How to diagnose a bad defrost board on a Goodman heat pump
15:34
Iron Shield Heating & Air
Рет қаралды 5 М.
Troubleshooting the Goodman Defrost Board
14:52
John Jennings
Рет қаралды 84 М.
Return to Freezing Heat Pump to Change Defrost Board!
10:16
escape in roblox in real life
00:13
Kan Andrey
Рет қаралды 92 МЛН