Hi sir, thank you very much for your tutorial. I still have a problem. Mine was down so i bought a new motor and card. it looks like the limit switches are not recognized. While autosetting, it just goes to the stop and then blocks and says KO. What could it be ? thanks
@BFTAmericasInc6 ай бұрын
Hello, so does the word stop come up on display and on the limits itself it should have a L and R and when you are facing the motor the L on the left side and R on the right side. You can also call us when you are at the motor if you need tech support 877-995-8155 option 3. You can also email us at tech@bft-usa.com.
@jumaniaccessories6538 Жыл бұрын
I’m from Dubai how r u sir
@belkocik3 жыл бұрын
can I put monostable button (like I got in house for turn on the light) in 60 and 61 pin and then it opens a gate?
@BFTAmericasInc3 жыл бұрын
As long as the dry contact that is connecting to 60-61 closes for about 1-2 seconds it should be ok. Also, depends how far away it is. If it is to far you might want the contact to close for about 2-3 Seconds.
@belkocik3 жыл бұрын
@@BFTAmericasInc about 10 meters away (in my garage). BTW Is it possible to connect shelly1 24v to open and close the gate too? Would you do a video about this?
@bentley92496 ай бұрын
Thank you mate 👌
@garygab4800 Жыл бұрын
I’m having trouble my gate is not closing all the way I have to manually push it to close
@BFTAmericasInc Жыл бұрын
when the gate stops what does it say on the display.
@ycho2 жыл бұрын
Is there a way to extend the TCA time? like using external timer and hooking it up to the BT600?
@BFTAmericasInc2 жыл бұрын
Sure, you can hook up a seven day timer or something similar. Just hook it up to the open command. Once the timer turns off, open command goes away and the regular TCA will count down and then close your gate. Hope this helped...
@ycho2 жыл бұрын
@@BFTAmericasInc my apologies, but how do I access the open command?
@saulgonzalez22233 ай бұрын
I received Error1
@Tluanga20082 жыл бұрын
Hi I got BFT 400, Can I reprogram, how? Is there any reset button?
@BFTAmericasInc2 жыл бұрын
Not really a reset button, but you can press and hold s3 for 5 seconds when ever you change a dipswitch or potentiometer to save changes. Also, you can wire in a N/C button to the 70-71 spot which is the stop command. That command will reset any faults that might have occurred while running.
@hvanhat2 жыл бұрын
Great videos thanks I just have a question - is there a way to program the remotes so that my one of the buttons has the auto close (TCA) but the other doesn't? (so for times where i want the gate to stay open?) I have the Deimos A 400 V Ultra
@BFTAmericasInc2 жыл бұрын
You have two options.... Option 1: Use the 4-step logic on the board. It comes default already with 4-step logic active, but just to make sure check in the "Logic" menu that STEP-BY-STEP is set to "0". Now that your set up, the way to use this function is IMMEDIATELY when the gate starts to CLOSE, click the remote and it should stop and stay there and ignore gate timer until you give the gate another activation. Option 2: Purchase a Clonix 2/E wired in receiver and use one button on the remote as normal and then program the second button to the latching command on this receiver. Check video out for option 2 here: kzbin.info/www/bejne/aKiqmYNqpbuVirM Hope this helped. If not write us at tech@BFT-USA.com and we will do our best to help you out.
@Huc_0092 жыл бұрын
Can you tell me how can i configure photocell to be active only when gate closing? Thank you in advance
@BFTAmericasInc2 жыл бұрын
No problem of course we can help!! If you have a UL version BFT then chances are your photobeam is tested and using 5 wire hook up. If it is, you want to go to the "Logic" menu you want to go to "safe 1" and change that value to the number 5 and push ok. If it is the non UL (or just 4 wire hook up) you want to change your safe setting to the number 4. If you need more assistance please reach out to us at Tech@BFT-USA.com.
@jfuqua723 жыл бұрын
Can you program this with the button built into the car?
@BFTAmericasInc3 жыл бұрын
Unfortunately our rolling code technology does not work with homelink, Check out our KHLKIT video! kzbin.info/www/bejne/oWSsfatrjKeChJo
@jfuqua723 жыл бұрын
@@BFTAmericasInc with the Deimos Utra BT A600 UL can I use the phone app? or does this require another module?
@marcinxt12773 жыл бұрын
How to program the remote control so that the gate opens in three stages - Pedestrian - Half open - Open
@BFTAmericasInc3 жыл бұрын
Please check out our mitto remote videos.
@martarodriguez89743 жыл бұрын
Having issue with programming. I select my LH and pre select I have it on AR, then on auto select it counts down but gate does not move. After I get a message KO when I click okay message appears ER01 ..... can anyone help
@davidburke43033 жыл бұрын
Your magnets or limit switches are not set up correctly
@BFTAmericasInc3 жыл бұрын
Anything ER01 or ER04 is directly tied to the Photo cells. Please check out our UL phot cell videos to verify proper wiring.
@Wpbandy Жыл бұрын
Mine says bar when i hit open
@BFTAmericasInc Жыл бұрын
Does it say bar when you hit the open command or does it move a couple inches then say bar.