Dell PowerVault MD1200 - Fan Control

  Рет қаралды 1,338

Administrator

Administrator

Күн бұрын

Short video on configuring the fan speed for Dell PowerEdge MD1200 equipment.

Пікірлер: 17
@administrator4728
@administrator4728 10 ай бұрын
00:45 - Wiring Configurations 01:55 - PuTTY Configurations 03:00 - PowerVault Commands
@administrator4728
@administrator4728 10 ай бұрын
-- Commands -- BlueDress.106.000 >_devils _boot Download the boot image (FW image 1 and 2 erased) _clrphyerr Clear PHY error counter(s) _date Date: date _debugpage2 Dispalys Page 2 data when Host read it : 0 = OFF !0 = Active _devils Print the Extended help _dwd_reset Disable WatchDog reset: dwd_reset _download Down load code using Xmodem: Region[0-9] Offset Erase[y/n] _download_fpga Down FPGA load code using Xmodem: _download_fpga _drive_pres Return Drive presense: _drive_pres _ecc Display ECC counts: ecc {clear} _ema_poll Turns on or off the analysis polling. Disables SES & LED update _erase Erase F/W Region: erase [0..10] NOTE: This can mess up your code! _event Event log test _fan_ctrl_thrd Write fan control parameters in C: fan_ctrl_thrd _flashdump Dump Flash: flashdump _fpgaread Read FPGA Register: fpgaread _fpgawrite Write FPGA Register: fpgawrite [ ...] _fail_ts Fail temperature sensor: fail_ts _flashpeer Flash Peer: _gpio_setting Read a GPIO Setting: gpio_settings _history Show CLI History: history _hotswap Enable/disable Hotswap _icid_clear Clears the ICID value to default. _isim_msg Send message to ISIM thread _ledconfig Show LED Configuration Settings _ledmode Set Mode for led: ledmode _ledread Read LED GPIO value: ledread _ledset Set LED GPIO Value: ledset _lm75_trip LM75 Interrrupt Control: lm75_trip _loadcpld Load xsvf file from flash into CPLD _map Display SES Sensor Data: map _phy_info Display SAS phy information _ps_pmb_test Test P/S Module PMBUS commands: ps_pmb_test _psfup P/S Module Firmware update: psfup _queue Dump the Message Queue usage: queue _quick Quick regression: quick _rdcam Read CAM Address contents , _rdtxphy Display current SASTX2G Phy settings _rdrxphy Display current SASRX2G Phy settings _rdphyerr Display PHY error counters _rdled LED Control Register Read: rdled _runtime Down load code using Xmodem to the non-active region: runtime _set_cid Set company ID of ELI: cid_set [0-From Exp, 1-Custom ] _shutdown Invoke a thermal shut down sequence: _shutdown _shutup Slow down fans: _shutup 20 default _slotled Control Slot LEDs: slotled (slot > MaxDrive = 'all') _splitforce Control Split Override: splitforce _ssc_control Turn SSC on or off _stack Show Stack Usage: stack _temp_rd Read current temperature values _temp_thrd Write temp thresholds: temp_thrd _test_stub test_stub _thread Display Threadx Information: thread _timer Display Timer information: timer _trace Display Trace Log [- for Tail] [+ for Head]: trace [-]count _traceclear Clear trace log: traceclear _twi_hang Hang the TWI bus for testing purposes only _ver Version Information: ver _wdt WatchDog test: wdt _who Who's home (installed): who _wrphy Write SAS2G1-3 Phy setting _wrphyall Write all SAS2G1-3 Phy setting _zone_mask Display Zone Mask for all PHYs BlueDress.106.000 >devils asset_tag Set or Display the Asset Tag: asset_tag {setvalue} asd_offset Set or Display the Auto-Shudown Offset value: asd_offset {setvalue} broadcast Send Broadcast SES Message: broadcast chassistype Display and or Set Chassis Type: chassistype clear_eel Clear Event Error Log: clear_eel clear_temp Remove override of Temperature: clear_temp dbs Database Read : dbs devils Print the Help Screen drive_led Write drive led: eepromdump EEprom Dump: eepromdump eepromfill EEprom Fill: eepromfill eepromwrite EEprom Write: eepromwrite fanlog Fan fault count for each power supply fan [8 per unit] fpgadisable Put FPGA in Slave Mode: fpgadisable> fpgaenable Put FPGA in Master Mode: fpgaenable> fpga_rd FPGA Access: fpga_rd fpga_wr FPGA Access: fpga_wr [ ...] fru_display Display FRU Status: fru_display fru_clear Clear Fru: fru_clear [0-SIM0, 1-SIM1, 2-PBP, 3-PS0, 4-PS1 5-SBP] fru_download Download Fru: fru_download [0-SIM0, 1-SIM1, 2-PBP, 3-PS0, 4-PS1 5-SBP] fru_read Read Fru: fru_read [0-SIM0, 1-SIM1, 2-PBP, 3-PS0, 4-PS1 5-SBP]] get_time get encl time: get_time gpio_rd Read a GPIO: gpio_rd heart_beat SIM Heartbeat Control: heart_beat [0=off !0=on] isim_debug Change or view isim stats: l4_test L4 integration manufacturing diag: l4_test lm75 LM75 Read Access: lm75 lm75_rd LM75 Read Access: lm75_rd lm75_wr LM75 Write Access: lm75_wr log_ipmi Log an IPMI Event:log_ipmi max6654 Display MAX6654 Registers: max6654 noise Write audible alarm: nvramread8 Read NVram 32bit area: nvramread nvramread Read NVram 32bit area: nvramread nvramwrite8 Write NVram 32bit area: nvramwrite [ ...] nvramwrite Write NVram 32bit area: nvramwrite [ ...] page_a Display drive SAS Address: page_a ps_status Get P/S Module Status: ps_status ps_cap Get P/S Module capability: ps_cap ps_clear Clear P/S Module Status: ps_clr ps_page Get P/S Module Status: ps_status ppid Set or Display PPID: ppid {fruNumber}{setvalue} prompt Prompt on/off rd_8 8-bit Read: rd_8 rd_16 16-bit Read: rd_16 rd_32 32-bit Read: rd_32 reset_peer Reset other SIM using GPIO reset Reset ARM using Watch Dog timer rev SIM Firmware and Diagnogstic Revision sas_address Display SAS Address from Phys: (option for magic addr ) sbb_status Set SBB status: sbb_set scratchpad Display Location of Memory Test Area: scratchpad service_tag Set or Display the Service Tag: service_tag {setvalue} ses_page Display SES Page: ses_page set_speed Sets Fan Speeds: set_speed 20 default set_temp set encl temp: set_temp ( -55 to 125 degrees C) set_thres Set P/S Module Fan Speed Threshold: set_thres shelf_led Write shelf led: twi_dis TWI device discovery: twi_dis twi_rd TWI device byte read: twi_rd twi_stats Dump twi statistics: twi_stats [clear] twi_wr TWI device byte write: twi_wr {0xff bytes max} twi_wr_rd TWI device wr/rd: twi_wr_rd wr_8 8-bit Write: wr_8 [ ...] wr_16 16-bit Write: wr_16 [ ...] wr_32 32-bit Write: wr_32 [ ...]
@administrator4728
@administrator4728 10 ай бұрын
-- Temps / 20% Fan Speed / Ambient 21.1c -- BP_1[2] = 32c BP_2[3] = 32c SIM0[0] = 40c SIM1[1] = 38c EXP0[4] = 64c EXP1[5] = 63c AVG = 44c
@frankorbis7474
@frankorbis7474 6 ай бұрын
i also just got a MD1200 and yes high fan noise so thanks a lot
@SteveHartmanVideos
@SteveHartmanVideos 6 ай бұрын
Success! my cable finally arrived... connected to old school hardware serial port, com1, 38400, defaults for everything else, connected... command "_ver" shows the output, version 1.01 from 2009, command "_devils" shows all the commands. Then I typed "_shutup 20" and the fans slowed down so much, I could no longer hear them from across the room AT ALL. I put my hand over the vents and its still moving plenty of air. here's the only issue.... once you reboot the shelf, it will lose this config (it doesn't save it) so you'll have to issue the command again. Some people have build a script to automate this. I have not gotten that far yet. That's my next project.
@HobieHighLife
@HobieHighLife Ай бұрын
please note there's 2 different commands... "_devils" and "devils" the "set_speed" command is in the "devils" list of commands
@ColtRice17
@ColtRice17 3 ай бұрын
Thank you. Great info and very use/helpful.
@Poncho42
@Poncho42 7 ай бұрын
This video helped a bunch! looking forward to the firmware update vid
@administrator4728
@administrator4728 7 ай бұрын
Consider it done. If you do intend to update the firmware, try and not brick your Dell PowerVault. kzbin.info/www/bejne/iGrHoYSZjN2rjNU
@DataCenterAce
@DataCenterAce 6 күн бұрын
Has anyone tried to convert the Compellent SC2 to the MD12. Not sure if the firmware is different but it is just a sticker over top of MD12.
@SteveHartmanVideos
@SteveHartmanVideos 6 ай бұрын
i just got one of these MD1200, how exactly do you know if its set up as one span or two? I can see all 12 drives on my HBA card using one single SAS cable.
@administrator4728
@administrator4728 6 ай бұрын
So you'd use 2 spans if you had two controllers inside your MD1200, that way one controller would handle 6 drivers and another for the rest of the drives. A single span has fail over where both controllers can handle the 12 drives. Use cases: You had two computers connecting to each of the controllers to access 6 drives each. Or two RAID cards in a single computer to access 6 drives each. General recommendation, use single span for any other use case. In your instance you'd be in single span mode.
@SteveHartmanVideos
@SteveHartmanVideos 6 ай бұрын
that seems like what I was thinking too. How do i konw if the system is sets up for single span? I am waiting for my LSI-9200-8e card. Also... I have been reading up that the front LED lights for drive status wont work unless I use a Dell HBA. what card are you using and do you have your drive status LED lights on? I understand that the drive activity will still work, either way, with Dell branded card or not. @@administrator4728
@SteveHartmanVideos
@SteveHartmanVideos 6 ай бұрын
I just ordered the password reset cable, can you post the link in desc for the commands and which command you used to reduce the fan speed? or did you use the windows app via Perc H8xx e Card? @@administrator4728
@MyArcheon
@MyArcheon 9 ай бұрын
Very useful ! A question : is any DB9-PS2 cable do the trick ? Thanks
@administrator4728
@administrator4728 9 ай бұрын
Pinout (facing the back of the controller): forums.servethehome.com/proxy.php?image=https%3A%2F%2Fi.imgur.com%2F58FO8iY.jpg&hash=ec812a4665ae4e113fc59603cfa2c51c ~ fohdeesha So "no".
@SteveHartmanVideos
@SteveHartmanVideos 6 ай бұрын
link to pinout no longer works... anyone else have a pinout diagram? @@administrator4728
Is your Dell R610 too loud? Here's how to fix it. | PowerEdge Tips
17:02
So Cute 🥰
00:17
dednahype
Рет қаралды 45 МЛН
Magic or …? 😱 reveal video on profile 🫢
00:14
Andrey Grechka
Рет қаралды 57 МЛН
Matching Picture Challenge with Alfredo Larin's family! 👍
00:37
BigSchool
Рет қаралды 52 МЛН
Dell PowerVault MD1200 - Firmware Update
6:57
Administrator
Рет қаралды 437
Do I need a SAS SATA or SSD Disk array
20:55
Leadius USA
Рет қаралды 16 М.
Our data is GONE... Again - Petabyte Project Recovery Part 1
11:55
Linus Tech Tips
Рет қаралды 2,6 МЛН
Buying a SERVER - 3 things to know
12:40
diyinfosec
Рет қаралды 118 М.
So Cute 🥰
00:17
dednahype
Рет қаралды 45 МЛН