Domestic G+2 Building column with 16mm 4 iron bars with 150mm spacing is enough.footing is 4.5'×4.5' and slab thickness 5' with 10mm rods spacing 6'.
@donaldjayasundara28243 жыл бұрын
Domestic G+2 building 12*9column with16mm 4 iron rods,6mm spacing is enough?
@dff93784 жыл бұрын
Great video Sir
@kusholhumedeo78514 ай бұрын
How about crank bar? .. and in the mid you can keep 200 mm... What does it mean?
@mihira33923 ай бұрын
Better to mention the recomanded max span for this section as well
@virothipentayya9962 ай бұрын
PLEASE SUGGEST
@chameerajayampathwanninaya997325 күн бұрын
max span < 12*depth
@akshayingavale77024 жыл бұрын
This is so useful video❤
@InderjeetSingh-lf4ib4 жыл бұрын
Sir but my personal experience the beam with 225 mm width will fail in some location so preferred 300 *300 beam dimension
@tapasbhunia88953 жыл бұрын
Sir is it for slab beam or plinth beam?
@meaifollowyourdreams51962 жыл бұрын
Sir, that means crank bars inside the beam for this type of G+1 storey building will not be required?
@akonitv97812 жыл бұрын
Sir what about G+1 with roof slabs, how much the size of column and how many deform bars?
@pprasantakumarlenka54358 ай бұрын
Is the 12 inch depth of beam including the slab thickness or excluding?
@irman31053 жыл бұрын
Sir, grade 20 ratio is 1:2:4, for 1:1.5:3 ratio is for grade 25..for reinforced structures
@saiyanbrothers29852 жыл бұрын
1:2:4 is M15 concrete
@sofiaburnok40254 жыл бұрын
No distance of column mention from the given size of beam as standard
@mrperfect26694 жыл бұрын
Thanks you so much mere bhai
@ranusingh97892 жыл бұрын
👍
@joemanflyer20019 ай бұрын
What is the maximum span for beam only using your minimums ? Thx
@mdzohaib17514 жыл бұрын
Sir ya same lacture second chenal par bhi samjana
@zonunsangarenthlei9533 жыл бұрын
What's the span of the beam you are talking about
@deograciasyabes7166 Жыл бұрын
9 x 12 mean after concrete cover or the other way
@alacrity21984 жыл бұрын
Sir Make a Video For G+2 Domestic building. Footing to Beam to Columns
@bishwanathyumnam52092 жыл бұрын
Including slab or not,
@anishanishkt52843 жыл бұрын
Span not specified, please maxium span for above said size of beam
@Mike-cd3yd3 жыл бұрын
Sir how about tie beam design? Thank you for your doing. I learnt a lot.
@rolandoroncales98843 жыл бұрын
5 meters spacing for the column is enough??
@bambhaniyahardik82863 жыл бұрын
What should be the dia of main bar if the distance between two column is 5.4m for g+1 residential building
@ramzysaikadatu73503 жыл бұрын
Beam should be rectangular. Right? Why 225x225?
@dnordface49673 жыл бұрын
Watching frm philippines,, sir can I use that size of beam 9"×12" for 5000mm distance of column?thank you and god bless.
@manjooralam4493 Жыл бұрын
Sir colum steel how many size
@sohelahemad389 Жыл бұрын
Sir clear span of column ?
@ideachannel28073 жыл бұрын
You not mention the span of beam??? Please reply
@jerrychibunna18924 жыл бұрын
In Nigeria we use 6" block for one storey building, can I use beam size of 6"x6" for my plinth beam and beams
@sathishyadav6343 жыл бұрын
Sir how to place reinforcement for slab for g+1 and which size of rebar should be used
@cahanapromeosr.91552 жыл бұрын
Thanks sir
@chimpanzee83513 жыл бұрын
I have a 200mm x 400mm beam For LS/RS 4-16mm top bars and 3-16mm bottom bars For Mid Span 3-16mm and 4-16mm for bottom And addition side reinforcements 2-16mm on both side.
@ayoubenaciri4 жыл бұрын
Thank you 🙏🙏
@alhagiesaitceesay42383 жыл бұрын
how about those of us using 6" or 150 mm CMU block, what would be the size of our beam
@cristyroxas28323 жыл бұрын
What is the minimum & maximum length of the beam.thank you.
@masroorshah46753 жыл бұрын
Ao sir plz try to show also in practical form .
@makoymarukoy29893 жыл бұрын
12 MM and 10 mm for 2 storey house is OK?
@deepakdhanabal71674 жыл бұрын
Sir, put same type videos of videos for different column spacing
@kruti9002 жыл бұрын
It should be 6 no of bar for g+1
@washpakistan9922 жыл бұрын
good video, but you didn't mention the maximum span between pillars
@Villagesingletamil Жыл бұрын
3 metres
@Villagesingletamil Жыл бұрын
Beam depth and steel Dia changing for span expansion
@abdulrasidlumna79834 жыл бұрын
How do I know the max. Spacing of the lateral ties?
@arshadkhan883 жыл бұрын
No Crank bar ?
@imteyazali34102 жыл бұрын
Dear sir, How to calculate the average spacing of ties, if a column having length of 3 m. The spacing of ties in CR (i.e. 1 m) is 125 mm and in NR (i.e. 2 m) is 175 mm. Thanks
@Villagesingletamil Жыл бұрын
150 mm preferable
@anishanishkt52843 жыл бұрын
Maximum span of beam please the above mentioned size of beam and steel
@iriliral63663 жыл бұрын
What about the span,earthquake zone?
@smartbuilderscivilengineer6113 Жыл бұрын
Ok sir this beam detail plinth beam or roof level beam explain it sir
@mustafamohammady6434 жыл бұрын
Thanks dear
@zulkarnainahmed82083 жыл бұрын
Not mentioned max. Length which is the most important.
@zulkarnainahmed82083 жыл бұрын
What will be the size of grade beam
@arnabdas45664 жыл бұрын
Sir design a over hanging beam for staircase with load of brickwork over staircase from lintel to 1st floor slab. The bar details and limit for over hanging.
@AdamAdam-vq4ul2 жыл бұрын
PLEASE, WHAT ABOUT FOOTHINGS
@amjadsalibu20204 жыл бұрын
What about the beam length
@clarojrmacanas53703 жыл бұрын
How about the grade of the steel?
@chandrakiran79254 жыл бұрын
Sir what about column and slab
@jaydeepganguly61442 жыл бұрын
For G+1 storied framed structure building what should be beam column dimension for rooms 12'x18' and 14'x16'