thanks for sharing sir..newbie ako sa solar system kaya malaking tulong for safe operation
@joelsenoja89113 жыл бұрын
Very good! You tackled those configurations where others vloggers didn’t. Tnx!
@ardierama4963 жыл бұрын
Thank you for the detailed explanation. i liked that you showed the voltage equivalent of the battery's state of charge.
@thegreenlifevlog2 жыл бұрын
Salamat po sir sa info😇
@toots3020ph6 ай бұрын
Tnx sir sa video marami matutunan, sa dc at ac side ba sir anong type at size ng electrical wire gamit nyo
@jbhometech75906 ай бұрын
AWG #12
@jojofrancisco73293 жыл бұрын
Thanks po very helpful tips
@ziadkhalil49132 жыл бұрын
Nice work and nice explanation, I have Deye inverter 8KW single phase I’m very happy with it but my parameters settings are not good if the generator is working the batteries dose not charge in the day and in the night equally the grad
@jbhometech75902 жыл бұрын
I didn’t try generator but it should work as designed, explore more on the parameters / software update..
@solarindependentutilitysystems2 жыл бұрын
Nice system!
@acealbertouano2 жыл бұрын
Hi. My DEYE "Grid Charge" is NOT WORKING. Even if I set to Grid Charge (checked) in the Time of Use. What's the possible problem? I set the time from 00:00 to 05:00, Grid Charge Checked. But still during that time, my battery is still discharging.
@jbhometech75902 жыл бұрын
HI ACE CHECK ALSO THE BATTERY FIRST, INSTEAD OF LOAD FIRST.
@jbhometech75902 жыл бұрын
Check grid charge, all time of grid charge, battery first, activate battery
@andreaspinelli8506 Жыл бұрын
Hello thanks for the video. I hope you can hepl me. When swich ogg the grid, i have 115V between L-PE and 115 between N-PE. How can resolve this question. In normal condition in italy we have 230V between L-PE and near 0 V between N-PE
@jbhometech7590 Жыл бұрын
In my set up my ground line of inverter is connected to the grid grounding and separated the grounding of PV panels about 5meters away. Our power system in Philippines in our area is Line to Ground 220V.
@danielbanaag8813 Жыл бұрын
sir pwd tnung anung model n deye yan kc blak kong gamitin yan yun may pwd cya ng turbine din, thax
@jbhometech7590 Жыл бұрын
Nasa video paki check 16:00
@gurunanaksolar59933 жыл бұрын
Good job
@reyanacito3044 Жыл бұрын
Para tumagal po Ang inverter o di mahirapan ilang % po ba dapat naka connect sa backup load at ilang % Naman dapat sa homeload?
@jbhometech759011 ай бұрын
Inverter designed to handle 5kw the lower the better to extend life. Regular maintenance also should be considered.
@mclads12 жыл бұрын
Ano po ilagay sa grid peak shaving
@jbhometech75902 жыл бұрын
Sa battery time of use.
@anethemia78572 жыл бұрын
Good day sir,alwys watchng ur vedios sir from cebu province. May konting tanong ako sir,kung magpower up ng deye sir,alin ang una e,on nah breaker sir?,yung sah breakr ng grid side,battery breakr or sah Pv breakr sir?.
@jbhometech75902 жыл бұрын
Make it sure na wirings are correct MY PERSONAL PROCEDURE 1. Power on ang inverter cb sa grid then input the parameters 2. Power on cb ng PVs then sa Inverter side, then the push button ng Inverter 3. Then cb ng battery ( before switch on the cb mag series ka ng 5-10 ohms 5watts resistor to minimized big sparks ) TRY KO GAGAWA NG VIDEO NITO. SALAMAT & BE SAFE ALWAYS
@carlitomalinaojr9 ай бұрын
sir gud pm 2 string ba yan ang deye na gamit mo..tanong ko lang puede ba ako mag connect ng pv 3x 550watts every string,,sano masagot mo sir malaking tolong sa akin na baguhan..tnx
@jbhometech75909 ай бұрын
Yes 2 string 5x450w per string sa akin. Yes pwede yan 3x550w per string sayo. God bless and be safe…
@marvinbautista56632 жыл бұрын
sir kapag sinelect mo yung time of use kahit di na ba icheck yung grid charge.susundin pa rin nya yung 60% tira sa 1 to 5am what if chineck mo yung grid charge sa tapat ng 1 to 5
@jbhometech75902 жыл бұрын
Q1. Yes i reserved ng inverter 60% ng battery gamitin lang pag may brownout Q2. Grid will charge the battery from 1-5 if you select grid charge
@varquez198710 ай бұрын
sir pano po malaman if hindi comfortable ang lithium ion sa inverter?
@jbhometech759010 ай бұрын
Walang reading ang Li-BMS
@pinaysolaristajhing9963 жыл бұрын
sir ano po kaya ang possible reason why yung inverter nag alarm kahit sa monitor naman normal po every morning po nag alarm po ang inverter 10kw ang system po hybrid naka parallel
@jbhometech75903 жыл бұрын
Normally pag mag alarm lalabas sa display. Try mo mag retight sa connections or baka may moisture partially grounded.
@mengnggapo49103 жыл бұрын
every 10:30 in the morning nag aalarm sayo maam? F39 fault sakin eh
@allzzizzwellzz58413 жыл бұрын
Can i use 48v wind turbine to the pv 2 of deye inverter
@jbhometech75903 жыл бұрын
I didn’t try it, but you can based on the manual.
@Normandz2 жыл бұрын
good
@jermaejarb2 жыл бұрын
sir my features poh ba ang deye na pag umaga sa solar panel xa kukuha nang power at pg gabi sa batteries na nmn at pg ma lowbat kusang mag transfer sa grid nang consumption?
@jbhometech75902 жыл бұрын
Yes po
@hermantoofa1868 Жыл бұрын
Hi bro, can you help me What are the parameter if i'm off grid system no grid connected
@jbhometech7590 Жыл бұрын
Same parameters bro.
@hermantoofa1868 Жыл бұрын
@@jbhometech7590 if i have gel battery?
@miaa45472 жыл бұрын
Boss tanong ko lang po pano kung ang lumalabas lang po sa generator ay “signal on”? Hindi po nag ssupply yung generator sa battery man o sa home load po.
@jbhometech75902 жыл бұрын
Hindi ko pa na try sa generator but it should charge the battery as the main purpose ng generator. Hindi din clear sa Deye manual. Better switch off yong loads then observed kung mag charge ba sa battery.
@jefsbequio49792 жыл бұрын
kaya ba paandarin ang 3hp water pump yan?
@jbhometech75902 жыл бұрын
Basta naka tie ka sa grid no limit of load. Kung off grid depende sa weather at battery reserved.
@gilbertmeneses Жыл бұрын
Sir bakit kaya ganun 5k deye ko 1st@ 2nd month after install. Nasa 18k bill 3rd@ month to present always 27k a month n
@jbhometech7590 Жыл бұрын
Check mo CT connection maybe nag supply ka sa grid
@gilbertmeneses Жыл бұрын
@@jbhometech7590 Salamat po sir try ko baliktarin or ilipat ko sa isang main cable line
@etv40752 жыл бұрын
sir, yun about sa ats mo, main output ba at eps ang nag switching para mag supply sa load mo?
@jbhometech75902 жыл бұрын
EPS yan incase no grid.
@etv40752 жыл бұрын
@@jbhometech7590 ibig sabihin sir, output 1 ng deye as normal,then reserve si eps load.. incase mqg browout,
@jbhometech75902 жыл бұрын
@@etv4075 sa ATS grid normal, EPS and reserve
@elbertmartinez74943 жыл бұрын
Sir pano kong gabie na!(hybrid setup) Tapos hindi enough yung battery back up sa load? Paano po sya e set na sa grid kukuha ang mga Acu?
@jbhometech75903 жыл бұрын
Naka gridtie set up to so automatically the inverter sa grid na kukuha. Same settings.
@elbertmartinez74943 жыл бұрын
@@jbhometech7590 thank you sir.. Sir after if mag weilding machine kami, saan ako pwede magkabit? Before CT or after CT? Thank you
@jbhometech75903 жыл бұрын
@@elbertmartinez7494 theoretically pwede naman yong welding basta separate breaker 30 amps lang at our own risk, di ko pa na try. Pero pina ka safe isolate mo yong inverter pag may welding works baka may effect sa electronic parts ng inverter depende kasi yan sa designer kung kinonsider nila yan.
@noelyap75632 жыл бұрын
sir idol ask ko lang po, may part na nalilito ako sa pv input voltage 100-500 volts anu po yan per mppt or para sa dalawang mppt yan? what will happen po kung sakaling sumobra sa voltage at current anu mangyayari sa inverter? meron ba syang protection something?
@jbhometech75902 жыл бұрын
Yup per mppt yan. Max pv power for 5kw =6500/2 for 2 mppt’s. May protection but just follow the manual, don’t take risk.
@marvinbautista56632 жыл бұрын
sir tanong lang.. yung lock out all change.. nilolock yung parameters ba...?
@jbhometech75902 жыл бұрын
Oo hindi yan ma change or ma edit kung naka lock na.
@arielcunanan88452 жыл бұрын
Good morning Sir, thanks in your valuable presentation. Magtatanong lang po ako about sa Deye at battery- Saan po ninyo nabili at magkano? Isa pa po, Ang existing na G.E. CB sa house ko ay may main 100 Amp at 6 branches,,, ang tanong ko sir saan ko dito i-connect ang Deye 5Kw Inverter sa AC in or AC out or may tamang idea na mas maganda at safe.Salamat po.
@jbhometech75902 жыл бұрын
Sa unli solar ko na bili ang battery at inverter. Sa manual ng inverter may diagram sa connections.
@GreekSIMRACING2 жыл бұрын
I wish i could get in EU this
@anjo71853 жыл бұрын
Nice sir!, Good day sir, Ask ko lng po if panu settings if wala pa ako battery , pero gagawin ko muna syang on grid , pero Hybrid inverter gamit ko po wala pa po kasing pambili ng battery, May iibahin po ba sa settings sir?
@jbhometech75903 жыл бұрын
Sa battery setting wag kang mag select. Kahit mag select ka ok lang din kasi wala naman ma detect ang inverter na battery. Yong ibang video ko wala pa ako noon battery.
@cloudsky19902 жыл бұрын
sir tanong lang po, ano po pwede mangyari kapag nka zero yung zero-export power 020, sa system workmode
@jbhometech75902 жыл бұрын
Hindi sya mag export to grid. Mag supply sya 20watts sa bahay kahit mataas ang production as per maker’s recommendation in reference manual.
@cyberbeast17893 жыл бұрын
sir ask ko lang if toroidal and low frequency na po ba itong klasing inverter na pwedi sa mga motorized appliances? salamat.
@jbhometech75903 жыл бұрын
Ang output po is pure sine wave opo pwede sa mga motorized loads
@varquez19873 жыл бұрын
sir ask ko po. may roon po ako deye na 5kw hybrid bibili pa ako ng solar panel... pwedi na ba yong 4 na 450w na panel muna? at saka anong connection non? salamat po .
@jbhometech75903 жыл бұрын
Pwede. Series connections. Ingat sa pag connect above 50 volts can kill.
@varquez19873 жыл бұрын
@@jbhometech7590 copy sir... thanks.
@ericksonmontes46263 жыл бұрын
Sir pwede po ba mag run yung DEYE po na hybrid inverter using solar generation only to supply po yung emergency load? wala ka Grid supply and Battery bank. thank you
@jbhometech75903 жыл бұрын
If no battery during brown out wala EPS. i connect mo lang muna as grid tie.
@joeyquiambao3680 Жыл бұрын
May tanong lang po ako bakit po ung grid ko nag X po sya kapag super tirik ng araw???
@jbhometech7590 Жыл бұрын
May alarm ba. Dapat hindi.
@joeyquiambao3680 Жыл бұрын
@@jbhometech7590 hindi nmn po ng aalarm … kapg mataas ung nakukuhang sinag ng araw dun po sya ng X…
@joeyquiambao3680 Жыл бұрын
Tapos mag normal ulit then after ilan minuto mag c po ulit sya.. nka net metering po kasi kami
@jbhometech7590 Жыл бұрын
@@joeyquiambao3680 ilan total kw ang panels at inverter mo
@jbhometech7590 Жыл бұрын
Review mo all settings specially voltages and frequencies then observe mo sa DU during that time. Software updates or try to reset. Hindi ako naka experience na ganito kaya yon lang ma suggest ko.
@rogilrosales60073 жыл бұрын
kaibigan thanks for your valuable vlog, can you pls explain how you mean "dead of discharge"? You said if the manufacturer recommends 80% dead of discharge, you set your battery to 75 dead of discharge. Pls. explain about it, thanks in advance!!!
@jbhometech75903 жыл бұрын
Ang DOD ng batteries nasa brochure or manual included when you buy or you can ask the seller. If 80% yon lang ang maximum na gamitin mo or 75% mas tatagal ang life ng battery. Sa video natin 48v system tayo kung 24 or 12 v system ganon din just follow on the DOD - % voltage table.
@KatutsLang Жыл бұрын
Hi :) sir, pa help naman. Nais ko ma achieve na setting sa DEYE 5K and 48V 100AH PowerWall . Battery will start and works in parallel with grid at 9PM Battery will stop once it reach 80AH discharge capacity. Grid will take over . At 8am Solar will start supplying the Load and and will also start charging the battery . Grid will help supplying the Load.
@jbhometech7590 Жыл бұрын
Message mo ko sa fb messenger JB Hometech or email tsbernal35@gmail.com
@jonathanregis26173 жыл бұрын
Sir ano po yung pinag kaiba sa setting na ZERO EXPORT TO LOAD compare sa ZERO EXPORT TO CT ? ano po ang function nya dun sa BACK UP LOAD at HOME LOAD.. baguhan lang po ako sa DEYE HYBRID ONGRID/ OFFGRID..salamat po
@jbhometech75903 жыл бұрын
ZERO EXPORT TO CT - not to export or supply to grid. ZERO EXPORT TO LOAD - i did not try this but i think ALL POWER PRODUCED FROM SOLAR WILL BE SUPPLIED TO GRID
@marvinbautista56632 жыл бұрын
meron dalawang load. backup load at home load, ang back up load connected sya sa load terminal ng inverter, ang home load connected sya sa grid terminal in parallel sa grid zero export to load.. hindi sya magffeed ng power sa grid terminal.. which means zero export sa load at grid ibig sabihin sa load lang sya magpopower. no need na rin ng external limiter zero export to ct.. hindi sya mag eexport beyond ct sensor.. which means mapopower nya ang homeload pero zero export sa grid ewan ko kung maggets mo explaination ko..
@vicsuarez11633 жыл бұрын
Tanong ko lang Fanless ba ang 5KW model na Deye Hybrid inverter na yan?
@jbhometech75903 жыл бұрын
May fan, nag add ako with timer later temperature controller. Pag ang load more than 3kW temp getting high.
@ianmarkolano45583 жыл бұрын
Good evening Sir. Tanong lang po ano purpose ng ATS nilagay nyo? Nag DIY din ako using Deye 5kW Hybrid Inverter.
@jbhometech75903 жыл бұрын
Pag mag brown out mag switch sya sa EPS mode supply lahat load sa bahay except 2 aircons nilagyan ko ng magnetic contactor coil supply from grid.
@jhorperez44112 жыл бұрын
Sir pwd ba yan gamitin yan sa off grid set up?
@jbhometech75902 жыл бұрын
Yes po. Hybrid on/off grid po itong Deye.
@jhorperez44112 жыл бұрын
@@jbhometech7590 salamat sir Isa pong tanong yung 320 amps na lifepo4 prismatic na battery Bali 16s 2p yun maging 640 amps na sya kaya ba ng 6amps active balancer?
@jbhometech75902 жыл бұрын
@@jhorperez4411 ok lang yan mostly gigamit 5amps sa active balancer lagyan mo rin ng bms. Mas maganda din na may lcd monitor yong each cells. A BMS controls and monitors your whole battery on cell level niveau, disconnects the whole battery in case of over or under voltage and prolongs the life of your precious battery. An active balancer just balances your batteries, shovels energy from a cell with higher voltage to one with lower voltage.
@franciszosa61543 жыл бұрын
Gdpm sir ano po ba ang diperinsya sa zero export to load at zero export to CT. DIY po ako sir ang setting ko po zero export to load tapos battery first..deye 5kw hydrid unit ko..ty po
@jbhometech75903 жыл бұрын
Naka off grid ka ba? Naka on grid ako kaya di ko na try yong Zero export to load. Ang ZERO EXPORT TO CT kung grid tied then walang net meter para hindi maka supply sa grid.
@mclads12 жыл бұрын
@@jbhometech7590 may setting po ba si deye if off gtid or on grid set up mo?
@jbhometech75902 жыл бұрын
@@mclads1 grid tie ako kasi kulang pa battery ko long term plan off grid if kaya na sa battery after upgrade.
@erobph52052 жыл бұрын
Ano pong Ckt Bkr Amp rating recommended for 5KW Deye inverter. (1) sa PV to inverter??? (2) sa Baterry to Inverter ex. pag 5KWH ang baterry??? (3) Inverter to Load EPS??? (4) Inverter to Grid? ?? Pwede po pa advise. Thank you
Gud day Po sir,, ask ko lng,, bakit namamatay Ang 5kw. Deye inverter ko... Mga 2 o'clock ng umaga..Hindi nman nag fault o walang nmang bown out... Bakit kaya Sir .. puwedi mo ba akng tulongan... Salamat Po...
@jbhometech75903 жыл бұрын
Check mo lines and contact ng circuit breaker sa 220vac, lcd ng inverter
@felixmaxino22873 жыл бұрын
Sir paano ba e konek sa WiFi I mean paganahin yong WiFi nya.