Love the videos Mitch. Learning a lot, thank you. Keep them coming please 👍
@maracservices6 ай бұрын
Thanks mate. I think you will like the next one then. Cheers
@HHK10906 ай бұрын
@@maracservices Can’t wait to see it. Big fan from the UK.
@kamalhamdi67396 ай бұрын
شكرا على المعلومات القيمة والشروحات خالد من المغرب الدار البيضاء متعلم مبتدىء
@robalexander73486 ай бұрын
A interesting fault Mitchell, i look forward to the next episode 🤔
@MagandRocky6 ай бұрын
The two screws floating around in the bottom of the board enclosure are meant to attach the heatsink to the board along with thermal paste, if the screws aren't installed and new paste wasn't applied that replacement board never had a chance.
@J.k3136 ай бұрын
The top right screw had seat sink on the threads. How the previous tech didn't see that is wild
@maracservices6 ай бұрын
As soon as I saw those screws I knew exactly where they were from. Like you said, they’re the ones that screw the board down to the heatsink. You make a good point about the thermal paste, there is a good chance it wasn’t applied and even if it was, it probably isn’t a good contact. I replaced that unit today so I actually have this old unit in the back of my van as we speak so I can see if thermal paste was applied.
@maracservices6 ай бұрын
@@J.k313 crazy stuff!
@chetmyers70415 ай бұрын
@@maracservices Please give us a report on the thermal paste.
@craigladewig31586 ай бұрын
Friday also had an RX50 with E5 error code - no refrigerant in system, windings measured fine - compressor had seized.
@craigladewig31586 ай бұрын
RX50's are just unreliable -
@nguontАй бұрын
@@craigladewig3158that’s what I always paranoid about. How would you confirm the compressor has seized if windings are fine. Would megga it out show it is down to earth ?
@jimmyteesahn6 ай бұрын
Is that a daikin specific inverter checker? I have a refco brand, not sure on its compatability with different brand units though.
@maracservices6 ай бұрын
It’s all good, yours will work with everything. I bought mine from Daikin but they’re all the same. Mine doesn’t have any branding on it.
@craigladewig31586 ай бұрын
I have Refco checker and works fine
@ameerjundi29 күн бұрын
Thanks for the video mitch
@Ahsan-zh2ou6 ай бұрын
Hi Mitch, how many years is warranty for changing parts.pcb board etc
@maracservices6 ай бұрын
I honesty don’t know what the manufacturers warranty is. A lot of manufacturers don’t warrant it once the packet is opened and I’m not even kidding haha. I think they’re covering themselves from hacks incorrectly installing parts and incorrect diagnosing. That’s not the consumers issue though because if the part doesn’t work from incorrect diagnosis then the air con repairer will wear that. So it’s important for the repairer to be pretty confident before buying parts. I think most air conditioning companies give 12 months warranty on their work.
@craigladewig31586 ай бұрын
@@maracservices I don't do warranty on inverter boards unless the supplier does warranty
@jixia6766 ай бұрын
Hi, Mitch. Have you seen a faulty inverter board and a seized compressor at the same time?
@maracservices6 ай бұрын
I have not, only one or the other to be honest .
@jamesmccann88966 ай бұрын
@maracservices Hey mate! The 7 on the remote is actually a T for test! With an e5 fault the high chance of compressor seizure with your failed board, good call with the condemn of unit Would have been good to see if you had a strong insulation resistance reading or not
@ameernoureddine52446 ай бұрын
Hey Mitch how do we get one of those tools?
@maracservices6 ай бұрын
I bought mine from Daikin however you can buy them online. Just search inverter checker. 👍🏻
@tonymontana89724 күн бұрын
Why are Daikins so unreliable ? I always advocate for Mitsubishi. Is that Inverter analyser for all inverter systems or just specific models of Daikins ?
@MusaManneh-b7h11 күн бұрын
Yea real interested an each to understand an good an you real on what you ar doing an you good to go good job Hard working
@GeneralAvitation6 ай бұрын
its nice to see an old girl every now and then. Whats the difference between the FTXS60FVMA and FTXS60GVMA i Have both and for the life of me i can't tell.
@maracservices6 ай бұрын
They’re the same just manufactured at different times. I can confirm they have the same cover and evaporator and I assume everything else is identical.
@GeneralAvitation6 ай бұрын
@@maracservices yeah the only notice that the outdoor unit has a different Daikin inverter logo it took me a while to notice
@maxd49686 ай бұрын
@@GeneralAvitation I have a ftxs60bvma and it is quite different to this
@GeneralAvitation6 ай бұрын
@@maxd4968 yeah the bvma and jvea was made way earlier than these they were one of the first types if daikin inverters they were replaced to fix the bad inverter design and the fact that most of them still used r22
@craigladewig31586 ай бұрын
Problem with this scenario , you now quote client on new inverter PCB because compressor windings measured good. Client gives go ahead for new inverter PCB. You install new PCB only to find compressor has seized. Now Daikin wont return the PCB as it has been installed and client has to fork out the cash for compressor. At this stage it would have probably been more cost effective to install new unit with 1 year warranty. I always quote replacement of compressor + inverter PCB vs new unit.
@maracservices6 ай бұрын
I get what you’re saying. You’ll be happy to know I replaced the entire unit on the Saturday just past.
@dalebaker15296 ай бұрын
I would do the same thing Craig You never get any thanks from anyone by faulting the pcb then ordering them come back to replace the part to find out it’s another part that’s in fault also Would always advise to replace the whole outdoor unit which comes with warranty
@glenjones44046 ай бұрын
Very true with all inverter compressors as damned if you do damned if you don't its a proper catch scenario I would quote for new out door as long as you can get the outdoor as they change to a new aircon model so then it's a new whole install and like he said it looks like it's had a new board in it's past or someone has been looking at it !!! I prefer working on refrigeration to be fair and only installing air-conditioning because even advice off Daikin and they say it's the board but it could be the inverter compressor wtf as you have to tell the customer ffs which doesn't sound reassuring 🤬
@dalebaker15296 ай бұрын
Daikin’s will keep you in a job for life Over priced units ,the quality has gone down hill massively in the last 15 years Would always advise my customers to go Mitsubishi electric
@せとやん-d9l6 ай бұрын
In the case of Japan, only certain people can get checkers. So I connected three analog testers in parallel and made an original checker😂
@lokmangoksal79706 ай бұрын
Dostum tesekkrler meslektasiz turkiyeden yaziyirum videolarini turkce alt yazi yaparsan iyi olur
@USA-GreedyMenOfNoIntegrity6 ай бұрын
You know you have a low quality units when the data plate is a label and is peeling off at 10 yrs…all units nowadays. Did you check communication? Install surge protector.
@maracservices6 ай бұрын
This unit was definitely over 15 years old. I couldn’t check for communication because the outdoor board was dead. I replaced the entire unit on Saturday
@technicsortechniques63736 ай бұрын
appareil photo e5 mechanical compressor lock possible to turn off the device is closed electrical switch in off mode in more than 6 hours after turning on your device it was working. 
@richardbartlett69326 ай бұрын
just swap out the outdoor unit. This board swapping is the road to hell. I've got a 2016 12.5kw unit with a bad board and I won't just swap boards. Its new condenser or nothing from me.. Been bitten too many times by Daikin to play those games. Esp when the price of parts+ time+ no warranty fitting matches the cost of a new outdoor unit with warranty.
@maracservices6 ай бұрын
@@richardbartlett6932 I have a genuine question, where do you get an outdoor unit for older models? I’d love to change the whole outdoor. That would be amazing, just as far as I knew that wasn’t an option. Daikin only stock current models (as far as I’m aware).