Noob guy to Colorado (I am from So Cal) so I am going to give this video a shot on my sprinkler system. Appreciate the easy how to. The service that did the winterize when we bought the house last Fall, wants $380 to do this. I will take my chances. THANK YOU
@DIYBRY2 ай бұрын
@@stiksandstones Hope you have good result! Thanks for watching! Subscribe!
@Nidalover2 ай бұрын
I'm from Colorado too, I got a small landscaping business, I can tell you that the price usually is $50-70 fo the first 6 zones and usually $5-10 extra per zone every extra zone, dont let people scam you, even big big professional and insured companies charge at maximum the double of that, but $380 is just too much unless you have like almost 25 zones. Like and extra to let you know and more people, you doesn't need to be a huge compressor with a huge engine, you only need 60PSI or less or your pipes can get damaged and if the tank is small just repeit the process until it's done, some people just to sell or get you calling every year will tell you that you need a huge compressor to get it done but it is a lie, DON'T LET PEOPLE SCAM YOU! always look for info.
@DIYBRY2 ай бұрын
@@Nidalover Could by a nice air compressor for that cost.
@davidcrowell5280Ай бұрын
I believe you should blow it out from the output side of the backflow preventer to avoid damage to the backflow valve. Am I wrong ??
@DIYBRYАй бұрын
@@davidcrowell5280 if you have a connection to do so, but most back flows I have see have the blow out connection at the water in side. As long as you stay in the 60 to 40 psi range, you should be just fine.
@asoggyburger479Ай бұрын
@@DIYBRY I’ve heard this too. I like how you opened the valve first though, I think that’s probably an important step to avoid excessive pressure within the back flow preventer. Personally I haven’t had any damage from winter freezes except 1 head. So I think any air in the system to move any water out will be helpful.
@DIYBRYАй бұрын
@@asoggyburger479 Less water in the lines, less chance of the water freezing 😉
@asoggyburger479Ай бұрын
@@DIYBRY Or worst case, plenty of room to expand without damaging the pipes lol
@DIYBRYАй бұрын
@ Indeed!
@TDace25Ай бұрын
If one drains and turns off the backflow and opens all the zones is blowing out the lines even necessary?
@DIYBRYАй бұрын
@@TDace25 There will still be water in the lines if you don’t blow it out. The water can freeze, expand, and potentially break your lines.
@TDace25Ай бұрын
@ Thanks. Used my compressor to do this today and was really easy.
@DIYBRYАй бұрын
@ Sweet! Glad to hear it. Subscribe 😎
@TDace25Ай бұрын
@@DIYBRY Subbed
@DIYBRYАй бұрын
@ Bodacious!
@mrcam5794Ай бұрын
1/4" or 3/8" air hose?
@davegould49402 ай бұрын
How many psi you set your regulator to?
@DIYBRY2 ай бұрын
@@davegould4940 A quick search of the web reveals "The ideal pressure for blowing out a sprinkler system is between 40 and 80 pounds per square inch (psi), but the maximum pressure depends on the type of pipe: Rigid PVC pipe: The maximum pressure is 80 psi. Polyethylene pipe: The maximum pressure is 50 psi. "
@fslater1022 ай бұрын
40 is sufficient. The higher the pressure the more risk of damaged lines. Even if your water pressure is 70 or 80, air has more viscosity and will travel through the system more violently.
@DIYBRY2 ай бұрын
@@fslater102 Though, depending on your tanks size, even if it starts out at 60, and you start draining, the PSI will drop quickly. So depends on the compressor. In mine, if I start out at 40, that’s would not be enough.
@weihsinchen38314 ай бұрын
Best winterization video I found so far! Just a quick question. How much PSI is safe for the sprinkler system when doing winterization?
@DIYBRY4 ай бұрын
@@weihsinchen3831 Thanks so much. 40-80 PSI. I would not exceed 80. Please like a subscribe :)
@JTGK132 ай бұрын
I have always seen that it says to keep it under 35 PSI when you have a backflow preventer so it doesn't damage it. I've also seen to turn the blue handle valves at a 45 degree angle as well.
@DIYBRY2 ай бұрын
@@JTGK13 A quick search of the web reveals "The ideal pressure for blowing out a sprinkler system is between 40 and 80 pounds per square inch (psi), but the maximum pressure depends on the type of pipe: Rigid PVC pipe: The maximum pressure is 80 psi. Polyethylene pipe: The maximum pressure is 50 psi. "
@edwinmyers900Ай бұрын
Why not open the other valves on either side of the vacuum breaker as well?
@DIYBRYАй бұрын
@@edwinmyers900 At which part of the process are your referring?
@edwinmyers900Ай бұрын
@@DIYBRY at the end when you open up the little valves to keep the airflow moving throughout winter. The bigger valves should be open as well right? Otherwise, you’re only letting air pass through a very small section between the two valves?
@DIYBRYАй бұрын
@@edwinmyers900 Yes. The actual sprinkler values (or zones) I leave those open. You can leave the "big" values on the back flow preventer open. The value that goes to the city should have a bleeder outlet on it, so it will drip the water out of the line that comes from the city. So, if you want to leave the big values open, that would be okay. More importantly would be insulating that backflow preventer. Get one that will fit yours: amzn.to/3Usm9cn
@edwinmyers900Ай бұрын
@@DIYBRY Awesome! I appreciate the explanation. Great video. Definitely the best one I found.
@DIYBRYАй бұрын
@@edwinmyers900 I appreciate that. Glad to help. Please Subscribe! 😎
@cb23547 күн бұрын
"That's what she said" at 3:39.🤣
@DIYBRY7 күн бұрын
@@cb2354 I try to “slip that in” to my videos from time to time. SUBSCRIBE for more 😂
@EdCAMPBELL-m2x11 ай бұрын
Ive been told numerous times to not blow air thru the backflow. Your hose fitting should be on the downstream side of it. Once the lines have been serviced, disconnect the backflow and take it in the house.
@DIYBRY11 ай бұрын
Interesting 🤔
@kkevinj18 ай бұрын
@@DIYBRY He is right, I have heard that 4 times today lol could damage it
@DIYBRY8 ай бұрын
@@kkevinj1 More power to you if you want to disconnect the backflow preventer every year and have to reinstall it every year. Adding back pipe-dope or teflon tape each time and making sure it is leak free.
@kkevinj18 ай бұрын
@@DIYBRY 2 unions🙂
@DIYBRY8 ай бұрын
@@kkevinj1 That is a good idea. Though then you would have two open pipes that would collect rain/snow all winter long. Could cap them, but then you would not have good air flow which could lead to frozen pipes. The fake rock like I have would cover the pipes while allowing them to be open, but with the fake rock, the entire back flow preventer is covered and has an insulation bag as well. So really, I think it comes down to personal preference and time you want to dedicate.
@slimpickens8589Ай бұрын
I followed this video exactly and I get no air blowing out of the sprinkler heads? I have an 8 gallon 4cfm compressor, hook it up and open the valve to zone and nothing?
@DIYBRYАй бұрын
Only one zone open at a time? Is the value the compressor is hooked to open, then one on the back flow preventer? When is the last time you used your sprinklers.
@slimpickens8589Ай бұрын
@@DIYBRY I ran the sprinklers right before trying to blow them out. I only had 1 zone open and connected the compressor to a connection after the back flow preventer. I thought the BFP was stopping the compressed air but not after I connected it after the BFL.
@DIYBRYАй бұрын
@@slimpickens8589 And the valve you have your compressor connected to is open?
@slimpickens8589Ай бұрын
@@DIYBRY Yes the connection port is definitely open. The only thing I can think could be happening is the compressed air is escaping through the back flow valve or the compressor just doesn't have enough cfm to push the water through the lines.
@DIYBRYАй бұрын
@@slimpickens8589 Hard to say since I cannot see.
@fslater1022 ай бұрын
Your putting 70psi of air in your sprinkler lines?
@DIYBRY2 ай бұрын
@@fslater102 Polyethylene pipe: The maximum pressure is 50 psi. Rigid PVC pipe: The maximum pressure is 80 psi.
@fslater1022 ай бұрын
@@DIYBRY What percent of systems you think use non-flexible field conduit of any kind? Maybe 2 or 3%? Even in a system using Rigid PVC, try opening an air valve going in a pipe with 0 psi, to 80 psi and let me know what happens to the connections and sprinkler heads. Maybe that could be your next video. Lets just say on the topic of max air in a sprinkler system blow out, we agree to disagree
@DIYBRY2 ай бұрын
@@fslater102 if you had a 10 or 20 gallon air compressor that could maintain a 40 psi for a decent amount of time. Enough to drain the whole system, then that would be awesome. I have a 3 gallon it’s not ideal but there’s no possible way it could maintain 40 psi for more than like three seconds. You also have to remember how long these sprinkler lines are. It’s not putting 60 psi outward force through the length of the tube all at the start. It never would even get that high anyways because the water is going to be forced out of the other end. The sprinkler lines are quite long. One of mine is over 100 feet. My little 3 gallon air compressor is not going to put enough pressure in the lines to do any damage even if I start out at 80 psi because by the time that it reaches the place in the line where the water is, it’s already lost most of that pressure just to get to the end of the line in the first place. Bottom line is it all comes down to which kind of air compressor you have.
@baileylarsen95176 ай бұрын
Very helpful thanks!
@DIYBRY6 ай бұрын
Glad to help! Subscribe! 😉
@ThomasCardall2 ай бұрын
Great video. Cost from my guy is $90 to blow it out. Cost for a 3 gallon compressor is $70. No brainer.
@DIYBRY2 ай бұрын
@@ThomasCardall Thanks for watching! I agree with you about n the cost benefit analysis. Good luck in your sprinkler winterizing efforts. Please Subscribe!
@DPRyan-vd5pp2 ай бұрын
Are you in highlands ranch, CO? That looks like a typical little backyard in highlands ranch! We live in Centennial Colorado and thanks for the video…we’re doing our system for the first time by ourselves.
@DIYBRY2 ай бұрын
@@DPRyan-vd5pp Thanks for watching! No, I am not in Colorado. Best of luck in winterizing your system this year. Hopefully this video helps. Subscribe! 😉
@kkevinj18 ай бұрын
Why did you have to cut the water off, you closed the ball valve on the preventer, why isnt that good enough?? So you closed 2 valves, just wondering why one isnt enough
@DIYBRY8 ай бұрын
From the city? All to prevent water in the lines on my property from freezing.
@kkevinj18 ай бұрын
@@DIYBRY Oh, ur house water is on separate line/meter? I tee in the water line coming in the house, cant shut mine off lol
@TheGreatQbert Жыл бұрын
Just a note from a professional here. 80 CFM is the recommended minimum to winterize a sprinkler system. Your compressor in your garage can push 3CFM. Because of how much thinner air is than water you need a significant volume of air to remove water from the system. When you blow out with a small air compressor you are only pushing a small amount of water out of the lines. It may be enough to prevent freeze damage but it is not likely.
@DIYBRY Жыл бұрын
Been doing this for years now. Never had an issue. But yes, a bigger compressor would be ideal.
@NervusEnergy2 ай бұрын
You only need huge amounts of air (CFM) if you are pushing water uphill. On a flat or downhill path to the sprinklers, gravity will do most of the work and lower CFM will work fine.
@chrisw.60602 ай бұрын
@@NervusEnergy@NervusEnergy Every one of these DIY videos on sprinklers I have seen always has some "Pro" come into the comments, telling everyone they need a pro to do it correctly. I wonder why. Could it be they are afraid they will lose business from their over priced services?
@supsnapАй бұрын
@@NervusEnergyI have a slight incline uphill for about 10 feet. Am I still good to DIY this on a 150 psi 6 gallon air compressor?
@supsnapАй бұрын
@@chrisw.6060I mean unless you're a national franchise I don't think that would be the concern here. Probably just being overly cautious based on experience. When you work in a field and experience an issue that arises 1% of the time, it's still a notable thing to remind customers of if you see a potential mishap.
@mistergabrieljensenАй бұрын
Tip: If waiting for the air compressor is the longest part of the process, turn it on first, then go deal with the valves and key and whatnot.
@DIYBRYАй бұрын
@@mistergabrieljensen Didn’t want the compressor roaring in the background while I talked about the other parts of the process.
@warrathblacktiger55662 ай бұрын
This is definitely not my state we have drains at base of the above ground breaker so the line drains and a master valve that shuts water from the whole system and a drain. We leave the drain plugs on the breaker wide open so the bowl dosnt bust some even take the top off as preventive and we rape the pipes and definitely don’t use iron pipes for sprinklers. They stop doing that in early 80’s around here. And we do same for inground breakers as well. We also bury lines 18 inch’s or lower below the freeze line. Iv never seen or heard of anyone using a compressor to clear the lines. Best way is just to run the system and open the drains and cut the system off it forces a back flow that drains the lines and since there are drains below the breaker it simply flushes the system
@DIYBRY2 ай бұрын
So what’s your state?
@secretface70Ай бұрын
You may want to add max air pressure before someone blows heads off their system
@rappmasterdugg68252 ай бұрын
"That's what she said" Hahahaha!
@DIYBRY2 ай бұрын
@@rappmasterdugg6825 I try to throw it in all my videos 😉
@mikeludvigson2 ай бұрын
That's what she said! lol
@DIYBRY2 ай бұрын
😎 thanks for watching! Subscribe!
@sparkzaddy24 күн бұрын
hey noobs. you don't need all the water out of the lines. just enough so it wont expand and bust your pipe.
@DIYBRY22 күн бұрын
indeed
@leeperreault8362Ай бұрын
i had to do a double take on the comment of "THAT'S WHAT SHE SAID" lmfao!!!
@DIYBRYАй бұрын
@@leeperreault8362 I throw that in my video my videos from time too time.
@dustinbramley4297 Жыл бұрын
Thats what she said lmao
@DougVandegrift2 ай бұрын
The problem with all these youtube videos is none of the hardware matches whatever I have. I have a hard time following
@DIYBRY2 ай бұрын
@@DougVandegrift What do you have?
@shawnkiesel5349 Жыл бұрын
Good God mow your lawn..
@DIYBRY Жыл бұрын
It had just rained, we were out of town for a week, my grass grows crazy fast and come on, it’s not that long.
@user-lt4en7pd4m2 ай бұрын
It's really not...guess this person likes having a putting green for a lawn