DIY - Pool Plumbing Pressure Test

  Рет қаралды 44,038

Seldom Rest

Seldom Rest

3 жыл бұрын

In this video we build a Pressure Test Manifold to check our new Pool Plumbing lines.

Пікірлер: 27
@scottmeczkowski1967
@scottmeczkowski1967 3 жыл бұрын
That manifold looks great, good thing you added the tie down, no one like a run away manifold
@nthnrnz33
@nthnrnz33 2 жыл бұрын
Thank you for the detailed video. We've built a 16' x 36' pool and completed the plumbing last night, only to learn that the first pool pressure test is done prior to backfilling using air. Luckily, I'll not have to cut off the two manifolds. I'll simply use your design with my existing unions! Thank goodness! You've saved me a lot of frustration, time, and expense.
@SeldomRest
@SeldomRest 2 жыл бұрын
Really happy you got value from this video! Hope your pressure test goes well and you can move on with the build and be swimming just in time for summer! Thanks for the comment.
@relaxsleeplearn
@relaxsleeplearn Жыл бұрын
Just what I needed
@SeldomRest
@SeldomRest Жыл бұрын
Great to hear! Thanks the comment.
@sharonmcintire1899
@sharonmcintire1899 Жыл бұрын
Great video. How are you threading that 1/2 in nipple into the 1/4 inch pvc bushing? Or is that bushing actually 1/2 inch female threaded?
@kendrealthompson8163
@kendrealthompson8163 2 жыл бұрын
Great video
@SeldomRest
@SeldomRest 2 жыл бұрын
Appreciate the comment! Thank you very much
@obeliskgroup5714
@obeliskgroup5714 2 жыл бұрын
This is a great video. Can you also build an open stem plug to create a closed loop, in case I need to add fix-a-leak (or any leak fixer product) to the faulty line? in my case is the suction line. I don't want the fixing product to be all over the system or the pool.
@SeldomRest
@SeldomRest 2 жыл бұрын
Hey there, thanks for the comment. I have not used any leak-fix products but don't why you couldn't modify this type of design to allow you to install as a closed loop. Check out LeakTronics channel, they have a ton of content covering leak detection and repair: kzbin.info
@johnswimcat
@johnswimcat 3 жыл бұрын
Good video. We need to pressure test a 1 1/2" solvent weld pool system before backfilling and concreting in so this is very helpful
@SeldomRest
@SeldomRest 3 жыл бұрын
Good luck with the project, and glad this video was helpful. Thanks for the comment!
@007billfish
@007billfish 3 жыл бұрын
How did you go about stopping up the return jets at the pool to maintain pressure?
@SeldomRest
@SeldomRest 3 жыл бұрын
On my skimmers I was able to use a threaded PVC plug and had to wrap the threads good with a teflon tape to get a good seal. Then on my returns I used an actual rubber plug that was made specifically for pressure testing applications. They are similar to a rubber winterizing plug, except instead of a tapered design they are a consistent size/circumference on both ends. I ordered them off of amazon for the PVC pipe size I had (2"). If you try to use the normal rubber winterizing plugs, be very careful as they will have a high chance of blowing out especially if you test up to 30 psi. I had tried this and had one blow out, would have been very dangerous had someone been in front of it. You can use a soapy water mixture to see if you are "leaking off" at either the plug size or on the actual pressure text manifold too. Let me know if this helps, happy to share more.
@jonathanmoss8252
@jonathanmoss8252 2 жыл бұрын
I guess you could use a decent cycle pump also instead of an air compressor ?
@SeldomRest
@SeldomRest 2 жыл бұрын
I would think so, should work just fine. Thanks for the comment!
@chrislegiadre7093
@chrislegiadre7093 2 жыл бұрын
do you have a parts list for this manifold that you can share?
@SeldomRest
@SeldomRest Жыл бұрын
Hey Chris, I don't have a parts list, but you should be able to find all of these materials at any big-box hardware store. Good luck with your project!
@steveroberts6879
@steveroberts6879 3 жыл бұрын
The ball valve is watertight but are we sure it's airtight?
@SeldomRest
@SeldomRest 3 жыл бұрын
I can say I was successful using air to test with no leakage from the ball valve at all, and I had lines under pressure for up to 24 hours. I did use a soapy water solution to check for any leaks, once everything was tightened up I was good to go. I know some people do use water instead of air to test with as well. Thanks for the comment!
@JeremyLevesque
@JeremyLevesque 2 жыл бұрын
Can you use all PVC?
@SeldomRest
@SeldomRest 2 жыл бұрын
Probably so, but as a few other's have commented, you just want to be careful anytime you have PVC under pressure with air. I think I've seen some all PVC designs available out there though. Thanks for the comment.
@liamconroy6698
@liamconroy6698 5 ай бұрын
30psi is pretty high when we only test gas lines to 5kpa/1psi
@tomallen7699
@tomallen7699 2 жыл бұрын
Water is far safer to use than air- you can compress air, can't compress water. Plus if it is leaking water, easier to find. 30 psi is high with air!
@SeldomRest
@SeldomRest 2 жыл бұрын
Thanks for the comment and feedback, great suggestion on the use of water as an alternative to air. Safety has to be a big focus anytime you pressurize a line for sure.
@vancegillenwater9609
@vancegillenwater9609 Ай бұрын
You didn't show how you stopped the other end, or used the air compressor to get 30lbs. you know the tough stuff.. you talked a lot in the first 2/3 about not much. This could have been a 3 min video. But thanks.
How To Find a Pool Leak Like a PRO! (pt. 1)
9:43
Hallmark Pool Supplies
Рет қаралды 441 М.
92% of Homeowners Use Teflon Pipe Tape Wrong - Here's Why it Leaks
5:33
Silver Cymbal
Рет қаралды 2,5 МЛН
你们会选择哪一辆呢#short #angel #clown
00:20
Super Beauty team
Рет қаралды 53 МЛН
How To Pressure Test A Swimming Pool - Lesson 1
11:18
Swimming Pool Steve
Рет қаралды 56 М.
Pressure testing Plumbing on a swimming Pool..STEP BY STEP
9:35
Crowley Pool Services
Рет қаралды 2,6 М.
Why are there Air Bubbles in my Pool? A Troubleshooting Guide
7:55
Jason Hughes
Рет қаралды 2,2 МЛН
Pressure Testing Our Drain-Waste-Vent Pipes
14:06
Mason Dixon Acres
Рет қаралды 16 М.
Compress Air with No Moving Parts! - Trompe
8:50
Practical Engineering
Рет қаралды 2,4 МЛН
Testing The Burn Ability Of Insulation In Wall
19:45
post 10
Рет қаралды 2,6 МЛН
Complete Installation: Watts 1” RPZ Reduced Pressure Zone Backflow Prevention Device
17:09
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 5 М.
Top 5 MISTAKES When Vacuuming Your Pool!
6:17
Hallmark Pool Supplies
Рет қаралды 235 М.
How To EASILY Tap Into PVC Water Lines(Best Method Using A Small Hole)
2:53
electronicsNmore
Рет қаралды 1,4 МЛН
How Wells & Aquifers Actually Work
14:13
Practical Engineering
Рет қаралды 4,3 МЛН
Отомстила слепой сестре 👍
0:55
NKino
Рет қаралды 2,4 МЛН
Поймал редкий кадр🤨
0:22
FERMACHI
Рет қаралды 3,9 МЛН
PUT CARDBOARD TOOTHPASTE ALL OVER ONE’S BODY!#asmr
0:40
HAYATAKU はやたく
Рет қаралды 16 МЛН
PUT CARDBOARD TOOTHPASTE ALL OVER ONE’S BODY!#asmr
0:40
HAYATAKU はやたく
Рет қаралды 16 МЛН