Sir, please DAF k upper bhi koi video bnaye detail me kya kaam krta h kaise kaam krta h Or iski kya process h
@gopalsonawane75742 жыл бұрын
Good sir.
@keshavbhoir753Ай бұрын
Sir anion bed me coustic soda hi use karte hai
@jitendrakumar44432 жыл бұрын
Good morning sir
@suhelkhan80492 жыл бұрын
Sir apka video bahut helpful , and knowledgeable but charging ke time motor band rahegi and kitne time tak charging k liye rakhna h, charging niche se uper hoga or nhi , aise hi mb bed ka concept clear kare pls pls sir etp ka jarur dekhe
@haddkardiaapne84474 ай бұрын
What happens when DM water passes through the SBA vessels.. ? What is contained its products (quality of output).
@manishsharma28376 ай бұрын
प्रकटीकल प्लॉट द्वारा करके दिखाया जाता तो और बेहतर होता की कैसे रिचार्ज होता है कैसै कया प्रोसेस होता हैं
@stylishsohanyadav42082 жыл бұрын
Good
@arvindkumarpatel7844 Жыл бұрын
Better use ke liye Dm water banane ke liye konsi methad vala plant lagana chahiye jinse costing Kam ho? Investment bhale Jada karna pade
@BuildingSanchalan Жыл бұрын
Mixed bed method.
@ganeshgvr2 жыл бұрын
Sir cation unit m apne sbc likha h wo Strong acid cation (sac) hona chaiye .
@BuildingSanchalan2 жыл бұрын
May be dear its a writing mistake. Thanks for watching carefully
@shaikshaboddin13652 жыл бұрын
DM water generation and Re-generation is both are different Generation comes under Raw water converted into DI water by using sand, carbon,cation,anion, and mixed bed. In time of re-generation we are using suitable chemicals like HCl into cation NaoH into Anion. We have the calculation how much quantity to be charge based on vessel capacity.
@BuildingSanchalan2 жыл бұрын
Dear Sorry, I dont have too much Idea.
@ramakantchaurasiya29832 жыл бұрын
Sir please chiller pe video banaeye
@Mechanical_guruji.5 ай бұрын
Sir resing kitna lena iske liye kya formula h
@mayurkachare88262 ай бұрын
It is not SBC it is SAC - STRONG ACID CATION , that's why Acid is used for charging, In SAC name it is mentioned that ACID!!
@sahilkhan8870 Жыл бұрын
How much % feeling cation and anion according vessel capacity?
@rizwanmazahiri1438 Жыл бұрын
Thanku
@Buatifulife1234 Жыл бұрын
I'm working in pharmaceutical company and my DM water plant has pseudomonas pathogen present when sample taken from cation anion and mix bed vessel and it's ten years old and it's charged by HCL and NaoH and sodium hypochlorite used for dosing to kill microorganism so let me know what to do for resolution please help
@BuildingSanchalan Жыл бұрын
You can use UV or ozonator for it and one more thing you can try to maintain 20 degree c water temperature it helps.
@gunjantiwari885810 ай бұрын
Degasser blower ka kitna discharge pressure mmwc minimum and maximum hona chaiye
@dineshparmar1473 Жыл бұрын
dm plant me ranig plant me sio2 bad jaye to pata kese chalega.. bina check kiye...
@BuildingSanchalan Жыл бұрын
Water flow kam ho jayega.
@AliIqbal2 жыл бұрын
Hi, can we make distilled water on RO plant through membrane?
@BuildingSanchalan2 жыл бұрын
No
@gayavantrajbhar50325 ай бұрын
How calculate obr Of DM plant
@Classic_hits05032 жыл бұрын
Sir please make a video how to calculate cooling tower fan efficiency, sump capacity, and how to calculate flow rate for chiller like 500 tr chiller take how much cooling tower flow and chilled water flow.
@AK_Royal1002 жыл бұрын
सर मिक्सबेड रि जेनरेशन कैसे करते हैं सबसे पहले कौन सा केमिकल चार्ज करते हैं और क्यों ????
Agar hamare soft water me t.d.s jayada he H.c.l castic ki matra kitni honi chahiye pintu hasti
@BuildingSanchalan7 ай бұрын
sorry me bata ni sakta kyonki yeh paani ke parameter per depend karti ha
@multi_skill_technician2 жыл бұрын
Fire fighting system pr video banaye sir
@harishtyagi5750 Жыл бұрын
Ro ki capacity kaise nikala jata h aur sac SBA WBA MB me pH TDs kitna mainten rhna chahiye
@BuildingSanchalan Жыл бұрын
alrready video uploaded.
@sunilmauriya72302 жыл бұрын
Mix bed mein kaun sa Wal resignation mein kholte hain aur kya karne ke liye
@bhartigor34752 жыл бұрын
Sir, mixed bed will be filled with HCL & NAOH?
@neerajpokhriyal79582 жыл бұрын
Sir difference between Ro plant and etp and dm plant Humko inki need kyu pdi ek se kam ni ho skta kya?
@Mechanical_guruji.5 ай бұрын
Example : 2000 ltr/hr trate karna hai to kitna resign ka design karenge formula please sir
@vinodkumarprajapati5182 Жыл бұрын
Please CO² plant operation per video banaye
@user-on8yb8wl3s4 ай бұрын
Calculation formula regeneration
@BuildingSanchalan4 ай бұрын
No actual calculation of regeneration because it depends on water quality.
@pramodborde6858 Жыл бұрын
Sir how much appx. Water is wasted for making 1kl dm water ?
@CHANDANKEGOTH Жыл бұрын
Bhaiya DM plant SAC ka working principle batao 🙏
@BuildingSanchalan Жыл бұрын
Bhai SBA ( Strong Base anion ) and SCA ( strong acid anion) dono chahiye. DM plant me. Dono hardness se chemical reaction karta ha.
@kuldeepbhandari20082 жыл бұрын
Pls make a video on WFI........
@santoshkumarmahto15928 ай бұрын
SBA ko HCl se regeneration kiya jata h sir g
@BuildingSanchalan8 ай бұрын
Thanks dear
@sukumarmitra28342 жыл бұрын
Softner me nacl kui use kiya jata he. Or nacl ka percentage kitni hogi?
@haddkardiaapne8447 Жыл бұрын
What happen If change the Cations and anions vessels... ? That means first installed or used the Anion vessel and then used Cations vessels . ???
@BuildingSanchalan Жыл бұрын
It will not work properly and will not parameters of permit water.
@avinashdubey42822 жыл бұрын
Sir lp aur hp Ka chemical HM DM tank m dose Kr skte h ya nhi yadi krenge to kya hoga
@raihanalam2019 Жыл бұрын
Hi, Ro filter mein agar TDS 5 to 8 aaya hai to kya Distilled water jesa hoga?
@footballarena6258 Жыл бұрын
No
@jitendramori542914 күн бұрын
Ketayan ka ph kitna hota h
@dmrandive54979 ай бұрын
Sir are you dealing in DM plant new one
@BuildingSanchalan9 ай бұрын
No, I am Engineer
@kennytekkzz Жыл бұрын
sir you can you also explain the functioning of WBA with SBA.
@BuildingSanchalan Жыл бұрын
Will try.
@kennytekkzz Жыл бұрын
@@BuildingSanchalan thank you sir. very well and precisely explained with proper diagrams for clear conceptual explanations.
@KaranSingh-ki3es2 жыл бұрын
Conductivity in micro simens
@iamanishkumar Жыл бұрын
Hello sir DM water plant me TDS 30 se kam nhi ho rha hai plz problem bataiye
@BuildingSanchalan Жыл бұрын
dost, aap ya to theek se recharge ni ho raha ha ya raw water ki tds bahut jyada ha.
@dwarikaprasad406229 күн бұрын
Anion ka PH kitna hota hai
@sunilmauriya72302 жыл бұрын
Mix bed mein bakwas kaise karte yah mixing kaise hota hai silo rans kaise karte injection kaise karte
@magadumpathan33212 жыл бұрын
Dm water PH regeneration ke bad jada kam ho jaye to kya karna
@nityanandpancholi514 Жыл бұрын
Sir g how do mix bed charging please a video uploaded Thanks
@ArvindKumar-ux8mk Жыл бұрын
There some steps for regenerate MB. Backwash Settling Caustic injection Caustic rinse HCl injection HCl rinse Air mixing Final rinse . If conductivity bot getting less than 1, then repeat air mixing and then final rinse.
@purnachandrajhodia Жыл бұрын
😊😊😊😊😊😊😊😊😊😊😊😊
@tutahuadil57962 ай бұрын
Kon sa resin hota
@suhelkhan80492 жыл бұрын
Sir etp ro k baare m kuch bataye stp ro se alag process hota h , jaise reject aur production line etp m low pressure ki se side se nikalta h mtlb stp ro ka ulta pls
@user-vx4kg7mw7y9 ай бұрын
ethonoll plant bary main jaankari de
@BuildingSanchalan9 ай бұрын
ethanol ke baare me jyada jaankari nai ha.
@jitendrakumar44432 жыл бұрын
D m plant five mitar ka hai pura regin bahar nekale hai regin change karna hai anion &cation regin ketna dale valu kase nekale
@AjayKumar-mb1jd2 жыл бұрын
Sir RO water bar bar trip ho rha hai over load per please
@BuildingSanchalan2 жыл бұрын
Check membrain
@nituupadhyay18522 жыл бұрын
You can choose for one of the above gifts
@BuildingSanchalan2 жыл бұрын
What
@rajaaditya0021 Жыл бұрын
Sir, how to reduce waste water quantity for the DM plant
@BuildingSanchalan Жыл бұрын
If we use best quality resin in cation, anion vessel and MB vessel. Mostly we cant reduse waste water of DM plant but we re-use some where and treat again thru other plant like STP, cooling tower, ETP where ever can be use.
@shabanali46868 ай бұрын
Diesel mein DM water pad Gaya hai uska kaise DM water pad Gaya uska kaise
@BuildingSanchalan8 ай бұрын
Diesel paani se hlka hota ha, paani neeche reh jaayega.
@vijaysagar326 Жыл бұрын
R/Sir, I have DM plant, I am using top - bottom vessel with MB. How to control pH, plz let me know., How I may contact you, thanks for explaing in details
@BuildingSanchalan Жыл бұрын
Is pH low or higj
@BuildingSanchalan Жыл бұрын
Mention your no I will call
@KaranSingh-ki3es2 жыл бұрын
Carbon filter de chlorination karta hai bhai
@BuildingSanchalan2 жыл бұрын
Han
@KaranSingh-ki3es2 жыл бұрын
@@BuildingSanchalan sir example about twaddle for cation and anion regeneration,how to check acidity of cation bed
@arunsharma-om6bl2 жыл бұрын
Hello harish have you ever done job in focus energy limited, jaisalmer as chemist.
@BuildingSanchalan2 жыл бұрын
No,
@milindbhalerao12012 жыл бұрын
Sir Hcl or naoh कितने पर्सेंट होना चाहिये जनरेशन के लिए कुछ कुछ है सब कुछ है ये स्टॅंडर्ड रहता है
@KHAUFxBEASTop Жыл бұрын
5 to 6% Usko Power Water Bolte hai
@prasantakumarsahoo44602 жыл бұрын
Sir ,STP mai ozonator Ka Kya kaam hota Hai, plz comments sir
@BuildingSanchalan2 жыл бұрын
पानी ट्रीट होने के बाद जो बैक्टीरिया बच जाता है उसको ओजोनेटर द्वारा खत्म कर दिया जाता है
@paulsenser2 жыл бұрын
Pls tell me about of reactive silica
@jitendrakumar44432 жыл бұрын
Please sir resin and cemical ka value kase nekale video coment kare
@mukeshgaur31102 жыл бұрын
Sir SBA & SBC ki service kitni hoti h.. Kitni ghnte bad reganeration krna pdega..
@BuildingSanchalan2 жыл бұрын
Its depend on water quality
@mukeshgaur31102 жыл бұрын
@@BuildingSanchalan Ok
@lalandhiwar65922 жыл бұрын
Sir sac and sba ka pH ke bare ak video
@mohammadimtiyaz58242 жыл бұрын
Sir ye raw water Kahan se aaya
@BuildingSanchalan2 жыл бұрын
From govt supply or Earth
@ANSHUkumar-ji4sd2 жыл бұрын
Battry ki pani ka plant k bare m bataye
@muselma85432 жыл бұрын
500 liter 25000 and 1000 liter 40000 rs
@dilipshah71532 жыл бұрын
Battery pani bana hi plant meliga sir
@manishrathod37162 жыл бұрын
Sir We have bacterial growth in DM water , so is there any solution which can be add ?
@BuildingSanchalan2 жыл бұрын
Without inspection, it is difficult to say anything
@masterfiberglassdoorsgujra56132 жыл бұрын
I wanna talk with you about plaster resin
@dharmauniverse2 жыл бұрын
Can we drink DM water??
@BuildingSanchalan2 жыл бұрын
No,
@dharmauniverse2 жыл бұрын
Sir how can we make etp water reusable? Can i get your whatsapp no??