sir at 34.27, the value of angle of load which is phi R is leading as per the question, then we should take phi R as negative na?.. Why we have put cos(50.19+45)
@shutter_buggies4 жыл бұрын
feeling lucky to choose ee
@priyanshugupta44222 жыл бұрын
sir at 35:18 why the phase angle of impedance Z not takan beside root(244). we are converting rectangular form of Z = 10+j12 to polar then it should be there na?
@kailash01810603 жыл бұрын
in ques 2 can you specify which model, you are using for the calculation?
@axelblaze0074 жыл бұрын
sir one doubt .. why we haven't used A B C D parameter with angle while calculating line charging current ... pls clear it sir.
@smrutiranjansamal10754 жыл бұрын
Because we only need the magnitude....
@ArivukkarasiSelvakumar10 ай бұрын
Also when we take angle of line impedance (10+12i) then in the final answer of Ir = 73.72 angle (-50.194), here angle is negative which means lagging in question it is said that leading power factor. How?
@chitrasenraj13184 жыл бұрын
Power electronics ka hindi lecture Aayega kya
@tejendrapal95134 жыл бұрын
Thanks 🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏🙏 sir
@vivekjhore83774 жыл бұрын
21.02 time pai apne jo Ir ki value put ki h uska angle apne directly kha se likh diya
@shutter_buggies4 жыл бұрын
17:16 pe ic current ka formula kaise aaiya
@Pahadi_online3 жыл бұрын
when no load Ic= Is as Ir =0 use this in ABCD equations you will get the answer
@Gayatrisoni1974 Жыл бұрын
zero voltage regulation ka formula kis lecture mein derive kiye hai
@yashrajgupta49743 жыл бұрын
sir video book wali link pe us page pe notification aa rha hai ki "please contact to a admin to add you as a member " aa raha hai vo video book ko access nahin karne de rahe 😔
@ronakbhatt54024 жыл бұрын
Thank you sir 🙏 ☺ 😊
@mokariyanaresh75113 жыл бұрын
At 30:08 pe I^2R kyu liya, I^2Z kyu nahi liya? And 3times kyu liya wo to total line impedence diya hua hai na?
@sayanbhattacharya28453 жыл бұрын
Power only dissipated in resistance...not in total impedence. *3 means for 3 phases. Total line impedence means...Impendence of entire length of 1 phase.
@amolsolanke28604 жыл бұрын
Nice sir....
@kunalsingh4156 Жыл бұрын
Sir, Notes are not available now. Please provide it again 🙏🙏🙏
@sketchmusic9434 Жыл бұрын
They are available in telegram bro
@safvankhanmpathan4323 жыл бұрын
Very good lecture....keep it up sir....
@Anup5874 жыл бұрын
Great lecture sir
@jayjadav10104 жыл бұрын
Thank you, sir!
@shivsrikakolum21003 жыл бұрын
Sir wo Vs/A - Vr / Vr hai na usme Vs/A kyu lia??
@bibhasinha59954 жыл бұрын
Thanks a lot sirr!!!
@mohitrongare40335 ай бұрын
Motivation for my life 37:54
@udaykiran763124 күн бұрын
At 40.52 min how did sir say that it is short line
@deepujasoria96364 жыл бұрын
P kW wale question me last me power √3VI*Cos(PHIr) lagaya hain but I ko 73.55 √3 se multiply kyo nhi kara , kyo ki jo current nikla wo to per phase tha na
@manashprotimgogoi92204 жыл бұрын
@deepu line me voltage ko per phase me nikala gaya root 3 se divide karke..matlab by default line star connected ho gaya...to star connection me to Line current = phase current ho gaya na