How to Design ANFIS Based Boost Converter Model in MATLAB Simulink Software | Dr. J. A. Laghari

  Рет қаралды 7,725

Dr. J. A. LAGHARI

Dr. J. A. LAGHARI

Күн бұрын

Пікірлер: 52
@muhannaddrakalsebai4839
@muhannaddrakalsebai4839 2 жыл бұрын
Jazaka Allah. It was a simple explanation how to apply ANFIS in MATLAB Simulink.
@DrJALAGHARI
@DrJALAGHARI 2 жыл бұрын
Thanks for the compliments.
@hamidov123
@hamidov123 Жыл бұрын
Thanks you si mush its thé first Time i understund thé anfis بارك الله فيك
@DrJALAGHARI
@DrJALAGHARI Жыл бұрын
Thanks for the compliments.
@oladipostephen8501
@oladipostephen8501 2 жыл бұрын
Thank you Dr. Laghari for all you are doing.
@DrJALAGHARI
@DrJALAGHARI 2 жыл бұрын
Thanks for the compliments. Do share it within your circle too so that they may also get benefit from it.
@jimohabdulramonaroyehun919
@jimohabdulramonaroyehun919 2 жыл бұрын
Thank you sir for your immense contributions to knowledge. Allow me to also use this medium to express my profound gratitude for wonderful KZbin video you have done in the past. I enjoyed all. Once again, thank you sir
@DrJALAGHARI
@DrJALAGHARI 2 жыл бұрын
Thank you so much for the compliments. kindly share it within your circle too so that they may also get benefit from this video as well as channel.
@jimohabdulramonaroyehun919
@jimohabdulramonaroyehun919 2 жыл бұрын
Alright sir. Regards
@jimohabdulramonaroyehun919
@jimohabdulramonaroyehun919 2 жыл бұрын
@@DrJALAGHARI Alright sir. Regards
@Syed-wb8lc
@Syed-wb8lc Жыл бұрын
Thank you DR JA Laghari
@DrJALAGHARI
@DrJALAGHARI Жыл бұрын
Most welcome
@Eng.ashrafLateef
@Eng.ashrafLateef Жыл бұрын
. Thank you for the interesting video .. I have a master's thesis on the use of ANFIS for a solar system and I am trying to control the output voltages .. and I assume that the load has changed after a short period of time from operation .. but there is a failure to maintain the output DC voltage level .. Note that the PI succeeded in maintaining the voltage opposite the ANFIS
@DrJALAGHARI
@DrJALAGHARI Жыл бұрын
Thanks for the comment. ANFIS needs proper training for all events. Therefore, try to train it properly to get the desired results.
@vibinrajan7636
@vibinrajan7636 2 жыл бұрын
Really, an informative & very useful content. Sir, kindly upload research topics on AI based "Energy Management System" on power systems..
@DrJALAGHARI
@DrJALAGHARI 2 жыл бұрын
Thanks for the compliments and suggestion. Ok I will try in the future.
@Kashifbhangwar103
@Kashifbhangwar103 2 жыл бұрын
muhnje University life jo behtreeen teacher Dr javed ahmed❤️❤️
@DrJALAGHARI
@DrJALAGHARI 2 жыл бұрын
Thanks for the compliments
@sebasthiranikathalingam9416
@sebasthiranikathalingam9416 9 ай бұрын
Thank you very much sir
@DrJALAGHARI
@DrJALAGHARI 7 ай бұрын
Thanks for the compliments.
@barisukauebari8563
@barisukauebari8563 2 жыл бұрын
Thank you Sir for the great work you are doing. Please can you also make video using GA and PSO to design boost converter. Thank you.
@DrJALAGHARI
@DrJALAGHARI 2 жыл бұрын
Thanks for the compliments and request. Sure. I will try to make video on this topic as soon as possible.
@Syed-wb8lc
@Syed-wb8lc Жыл бұрын
If i want to apply two or more than two ANFIS controllers then how can I apply them Sir??
@DrJALAGHARI
@DrJALAGHARI Жыл бұрын
Thanks for the comment. Just use two blocks and train them separately and use them in the model.
@attiqullah5195
@attiqullah5195 2 жыл бұрын
where is ANFIS data to use for training...?? Plz provide it.. As you have uploaded for AVR ..
@DrJALAGHARI
@DrJALAGHARI 2 жыл бұрын
Thanks for the comment. The file link is given in the description section of the video.
@nomanmreedha5235
@nomanmreedha5235 10 ай бұрын
How to train the model for boost converter with variable input?
@DrJALAGHARI
@DrJALAGHARI 10 ай бұрын
Thanks for the comment. For variable input use the varying signal by using signal builder block or something like that to include all values then train the model with the anfis.
@nomanmreedha5235
@nomanmreedha5235 10 ай бұрын
@@DrJALAGHARI I've used the signal builder block. I meant in the workspace how to change the output data? ( this is not the conventional boost converter,I'm trying to optimize a converter I found in a paper) I tested the duty cycle needed for specific input voltages. For example my dc input varies from 80v to 40v. For input 80-74v range there were overshoot and undershoot. So I checked the duty cycle needed for 80v,78v...74v. There were 2000000 samples in total, so I divided all the samples by 40. That gives 50000 samples per unit voltage. And then I changed the output for each 50000 samples with the duty cycle I obtained before. But that's not working,the output is worse than what I got from the PID controller. Am I doing it wrong?
@DrJALAGHARI
@DrJALAGHARI 10 ай бұрын
@@nomanmreedha5235 thanks for the comment. In that case, kindly follow the paper methodology.
@nomanmreedha5235
@nomanmreedha5235 10 ай бұрын
@@DrJALAGHARI The paper used normal PID controller. I'm trying to get better result than that.
@saleemriaz5760
@saleemriaz5760 2 жыл бұрын
AOA respected Sir can you please share the code or video for Grey wolf optimization method ? GWO algorithm
@DrJALAGHARI
@DrJALAGHARI 2 жыл бұрын
Wa'alaikum salam thanks for the comment. At the moment, I don't have this code. But you may search it in Google.
@nimrahsaeed002
@nimrahsaeed002 2 жыл бұрын
Much appreciated. Sir, are you in Pakistan right now?
@DrJALAGHARI
@DrJALAGHARI 2 жыл бұрын
Thanks for the compliments. Ye. I am in Pakistan.
@nimrahsaeed002
@nimrahsaeed002 2 жыл бұрын
@@DrJALAGHARI sir can i have your email address plz
@MuhammadHamza-vy2ls
@MuhammadHamza-vy2ls Жыл бұрын
Can we use this with Mppt solar ?
@DrJALAGHARI
@DrJALAGHARI Жыл бұрын
Thanks for the comment. Yes sure you can use it with MPPT solar.
@EISHANSHARMA
@EISHANSHARMA 10 ай бұрын
what if there are multiple inputs in a controller
@DrJALAGHARI
@DrJALAGHARI 10 ай бұрын
Thanks for the comment. You can use more than one inputs if they are required. In that case use the multiplexer block and combine them in one signal and then give to ANFIS.
@RevathyKP-rv8gs
@RevathyKP-rv8gs 9 ай бұрын
SIR CAN YOU POST VIDEO ON PSO OPTIMISATION IN DAB CONVERTER
@DrJALAGHARI
@DrJALAGHARI 7 ай бұрын
THanks for the comment. No. I dont have.
@dnhj24
@dnhj24 2 жыл бұрын
Sir,can we design anfis for buck converter
@DrJALAGHARI
@DrJALAGHARI 2 жыл бұрын
Thanks for the comment. Yes. Ofcourse. You can apply ANFIS for a buck converter too by following the same strategy.
@mahfoudiarabah8684
@mahfoudiarabah8684 Жыл бұрын
thanks
@DrJALAGHARI
@DrJALAGHARI Жыл бұрын
Most Welcome
@nachobunbury9111
@nachobunbury9111 2 жыл бұрын
make discrete wavelet transform video in hdl
@DrJALAGHARI
@DrJALAGHARI 2 жыл бұрын
Thanks for the comment. What do you mean by hdl?
@electrictrick1360
@electrictrick1360 2 жыл бұрын
Hi
@ataurrahmaneee6492
@ataurrahmaneee6492 2 жыл бұрын
plz check our mail. have some problem task sent to you.
“Don’t stop the chances.”
00:44
ISSEI / いっせい
Рет қаралды 62 МЛН
Cat mode and a glass of water #family #humor #fun
00:22
Kotiki_Z
Рет қаралды 42 МЛН
Fuzzy Logic Controller Tuning | Fuzzy Logic, Part 4
18:29
MATLAB
Рет қаралды 35 М.
Inside the V3 Nazi Super Gun
19:52
Blue Paw Print
Рет қаралды 2,8 МЛН
Boost Converter with PI Controller in Matlab / Simulink
15:05
Control Circuit
Рет қаралды 3,4 М.
Simulink Control Systems and PID,  Matlab R2020b
23:13
Nikolai K.
Рет қаралды 205 М.
The Future of Auto Manufacturing: AI Driven Design
20:17
New Mind
Рет қаралды 990 М.
Modeling and Simulation of Advanced Amateur Rockets
17:10
Lafayette Systems
Рет қаралды 152 М.
“Don’t stop the chances.”
00:44
ISSEI / いっせい
Рет қаралды 62 МЛН