Good day! I wanted to know the specific size of the hole saw used to drill for the sensor
@TechnotonEN2 жыл бұрын
Good day! Hole diameter 39 mm.
@kamalakannansubramaniam37275 жыл бұрын
Very nice presenting the explanations.
@mr.write14336 жыл бұрын
Does it have a normally closed contacts or open ? is it applicable for gen set specially for the external pump
@tumusiimebrighton65292 жыл бұрын
Hey am to install a DUT E is the orange wire always brown wire always connected to the ground or it is some times change the colour code
@TechnotonEN2 жыл бұрын
Hello, our technical specialists will help you with the connection, write to support@technoton.by
@AlexSBedini8 жыл бұрын
Hi I am installing the DUT E AF tomorow, can I ask if calibration through SK DUT E kit is necessary for this FLS to work properly?
@ojwekegeorge75768 жыл бұрын
On tractors is it possible to use CAN BUS to read fuel?
@TechnotonEN2 жыл бұрын
If there is fuel data in the CAN bus of the tractor, it is possible.
@atsplsalesbelgaum9932 жыл бұрын
what if we drain below 5 ltr? do we get results?
@TechnotonEN2 жыл бұрын
Hi. Thank you for the question. Yes, you'll detect that. DUT-E sensor's measurement step is 0.1mm. That means, if you have 1,000 liter fuel tank, which is 700 mm high - the sensor detects ~0.15L fuel change. But accuracy hugely depends on fuel tank shape and precision of calibration. Please, contact us for further information jv-technoton.com/contacts/
@alsavage12 жыл бұрын
The DUT-E Operation Manual says that the probe is to be installed (in most cases: shortend/cut) to no less than 20mm above the bottom of the tank, (page 29). That means the effective measurement range does not include that bottom 20mm, and they actually specify 20-30mm. Depending upon your tank volume and shape, it's may or may not show any above-empty reading for your last 5L capacity.
@Stunningmotionsdigitalagency8 жыл бұрын
What is the price of this digital sensor. We are looking fuel monitoring device in Pakistan having features like sms alerts, report generate over consumption and when engine stops.
@adnanmusic59318 жыл бұрын
Which is diferences between analog and digital sensors and which sensor is better for usage
@JesusParrafull8 жыл бұрын
Hello Adnan, there are a big difference between the analog sensor and the digital sensor, the analog sensor provide the information in voltage (so you need a device with an analog input to read this information) and the digital sensors provide the information through the interface RS--232 or RS-485... Here is the operation manual, hope it helps you!.. www.jv-technoton.com/data/dc/DUT-E_SK_DUT-E_operation_manual.pdf
@adnanmajeed61788 жыл бұрын
Digital is the best
@samramusic85418 жыл бұрын
Why?
@nicholasanjiri47825 жыл бұрын
can fuel level sensors fitted in petrol station tanks? Or its only meant for small tanks like those on vehicles.
@latemakgroupe8463 жыл бұрын
Yes it can fit in petrol station tanks
@amazingsite25814 жыл бұрын
Could you upload the FUEL LEVEL SENSOR INSTALLATION GUIDE specially DUT-E S7? I have received the sensor but there is no installation guide yet
@TechnotonEN2 жыл бұрын
Hello. You can download the manual for the sensor in our document center: docs.jv-technoton.com
@murugesan4948 жыл бұрын
Hello Lenon, I hope you are fine, I need to know, have you appointed any dealer for your product in India (especially in south India), please update.
@tonydavis45763 жыл бұрын
You probably dont care but if you're bored like me during the covid times then you can watch pretty much all the new movies and series on InstaFlixxer. I've been streaming with my gf for the last couple of weeks xD
@jaxxanthony53503 жыл бұрын
@Tony Davis yea, I have been using InstaFlixxer for since november myself =)
@mouniroldmhb30562 жыл бұрын
How can you sent me all the system to Algeria please
@TechnotonEN2 жыл бұрын
Hello, please write to us at marketing@technoton.by
@jameskazimoto68237 жыл бұрын
how do i connect to the actross benz
@vyryx7 жыл бұрын
salut cum fac sa scot motorina fara sa stie acest senzor?
@ivo.sinapov8 жыл бұрын
Hello, Why the fuel level in mm. at the last filling goes more than the cut length ?
@aanpilogov8 жыл бұрын
do you mean readings of 530.4mm at 18:50?
@gopichandkunamaneni57903 жыл бұрын
What is the drill size?
@TechnotonEN3 жыл бұрын
Hello, the hole will be 39mm in diameter.
@rinaldopastelli77495 жыл бұрын
On barges is it possible?
@TechnotonEN2 жыл бұрын
Hello. Yes, this is possible, but we recommend that you take a closer look at the fuel flow meters. You can get more detailed advice by writing to marketing@jv-technoton.com
@Ahmedi12343 жыл бұрын
Very good but mistake you made you didn't show us how to set leve,s and ather,s by diagonals or computer??
@TechnotonEN3 жыл бұрын
Thank you for your comment. Have you purchased our sensor? You can write to us in support at support@technoton.by, you will be advised on this issue.
@ghanshyambhaiakhani82994 жыл бұрын
Fual leave installation charges?
@TechnotonEN2 жыл бұрын
Hello. Please send your request to marketing@jv-technoton.com
@rock4us210 жыл бұрын
Is it the same as the DUT -E 232 fuel level sensor?
@TechnotonEN10 жыл бұрын
DUT-E 232 is designed to work with RS-232 interface, and DUT-E 485 with RS-485 interface. That is the main difference. They are quite similar. The Manual can be helpful if you need in-depth comparison: www.jv-technoton.com/data/dc/DUT-E_SK_DUT-E_operation_manual.pdf
@rock4us210 жыл бұрын
Thanks Technoton EN for your reply. We are trying to configure the RS-232 sensors in pair to work with a Mix Telematics Fleet Manager Communicator goo.gl/uBRZXS unit but we are failing.
@TechnotonEN10 жыл бұрын
Lennon Emmanuel I have forwarded this information to our support team. Please leave us a contact email so our specialists can get in touch with you.
@rock4us210 жыл бұрын
Technoton EN i will inbox you my email adress
@rock4us210 жыл бұрын
i cannot find the inbox option Technoton EN my email is rock4us2@gmail.com
@adnanmajeed61788 жыл бұрын
Hi, Same procedure for RS- 232 ?
@sergeyp12808 жыл бұрын
Yes, the procedure is the same for RS-232 and for other interfaces.
@upparahalsomashekar82474 жыл бұрын
@@sergeyp1280 where it is available?
@sergeyp12804 жыл бұрын
@@upparahalsomashekar8247 Please write your inquiry or questions to sales@jv-technoton.com and you will be provided with all required information.
@galihwibisono97856 жыл бұрын
How to check the data?
@TechnotonEN6 жыл бұрын
DUT-E is used in GPS tracking as additional fuel sensor or as a replacement of standard built-in (factory) fuel level sensor. Information on compatibility of fuel level sensors DUT-E and tracking device: www.jv-technoton.com/compatibility/
@kalaiselvan24044 жыл бұрын
How much price sir
@TechnotonEN3 жыл бұрын
Hello, please tell me your e-mail. Our manager will send you all the information you need.
@sghauri27 жыл бұрын
I LOVE U GUYZ WELDONE
@deepeshenterprisesvivekmis45976 жыл бұрын
Nice
@himanshudipanshu4330 Жыл бұрын
Rs
@TechnotonEN Жыл бұрын
Hello, the price depends on the model characteristics. Email us at sales@jv-technoton.com
@mirjaafrozbaig7961 Жыл бұрын
Sir paric
@TechnotonEN Жыл бұрын
Hello, thank you for your interest in our product. The price depends on the model characteristics. Please, email us at sales@jv-technoton.com for product consultation
@decencydecorum4 жыл бұрын
too much background noise causing headache
@mouniroldmhb30562 жыл бұрын
How can you sent me all te system to Algeria please ?
@TechnotonEN2 жыл бұрын
Hello. Please send your request to marketing@jv-technoton.com